Bachelor of Engineering in Electrical & Electronics engineering, from Manipal University, (Karnataka), India in 2006. Presently involved in the design of EHV outdoor substation and coal fired thermal power plants for more than seven years. Motto of joining EEP as a contributor is to share my little engineering experience and help the budding engineers in bridging the conspicuous gap between academics and Industrial practice. “If you have knowledge, let others light their candles with it, so that people who are genuinely interested in helping one another develop new capacities for action; it is about creating timeless learning processes".
Sizing of power cables for circuit breaker controlled feeders (part 2)
Continued from article Sizing of power cables for circuit breaker controlled feeders (part 1) This criterion is applied so that cross section of the cable can carry the required load… Read more
May 13, 2012 | By Asif Eqbal
Sizing of power cables for circuit breaker controlled feeders (part 1)
The following three criteria apply for the sizing of cables for circuit breaker controlled feeders: [fancy_header]I. Short circuit current withstand capacity[/fancy_header] This criteria is applied to determine the minimum cross… Read more
May 10, 2012 | By Asif Eqbal
Capacitor Banks In Power System (part four)
Let us consider that there is a captive diesel generator (DG) the rating of which is specified as 1000kVA and PF 0.85. Rating in kVA specifies the maximum current the… Read more
Mar 27, 2012 | By Asif Eqbal
Difference between step-up transformer and voltage amplifier
A step up transformer basically increases the magnitude of primary applied voltage that is increases the amplitude of voltage wave form. A voltage amplifier does exactly the same. Than a… Read more
Mar 17, 2012 | By Asif Eqbal
Different types of battery used for auxiliary power supply in substations and power plants
In industrial or substation applications mainly three types of batteries are used namely: Vented / Flooded Lead Acid batteries Sealed maintenance free batteries/Valve Regulated Lead Acid Nickel Cadmium (Ni-cd) batteries… Read more
Mar 12, 2012 | By Asif Eqbal
Capacitor Banks In Power System (part three)
Continued from part two – Capacitor Banks In Power System (part two) Capacitor units shall be suitable for continuous operation at an RMS current of 1.30 times the current that… Read more
Mar 03, 2012 | By Asif Eqbal
Capacitor Banks In Power System (part two)
Continued from part one – Capacitor Banks In Power System (part one) It should be noted that in an inductance the current lags the voltage by 90 degrees and in… Read more
Mar 01, 2012 | By Asif Eqbal
Capacitor banks in power system (part 1)
When a charge is delivered to a conductor its potential is raised in proportion to the quantity of charge given to it. At a particular potential a conductor can hold… Read more
Feb 27, 2012 | By Asif Eqbal
About Permeability And Permitivity
The strength of electric field or electrostatic force strength or intensity of field (all synonymous terms) is measured & expressed in terms of force experienced by unit positive charge placed… Read more
Feb 01, 2012 | By Asif Eqbal
Anti Pumping And Lockout Relays
What is ANSI code for Antipumping relay? ANSI codes 94 or even 52 can be used. Relays can be divided into six functional categories shown below: Detect defective lines, defective… Read more
Jan 23, 2012 | By Asif Eqbal