Edvard Csanyi
1671 awesome technical articles
Electrical engineer, programmer and founder of EEP. Highly specialized for design of LV/MV switchgears and LV high power busbar trunking (<6300A) in power substations, commercial buildings and industry facilities. Professional in AutoCAD programming.
Recommended and commonly applied protection for transformers
The protection that is recommended and commonly applied for transformers is summarized in the following figures. It should be noted and recognized that these are general recommendations, not strict. More… Read more
Jan 12, 2018 | By Edvard Csanyi
What is what in outdoor HV substation? How to identify elements by shape and function?
It’s not always an easy task to explain what is what in high voltage substations. Shapes of the major elements are mostly similar through substations, but there are also combinations… Read more
Jan 10, 2018 | By Edvard Csanyi
HV Transmission Line Components (Towers, Conductors, Substations, ROWs and Roads)
The towers and conductors of a transmission line are familiar elements in our landscape. However, on closer inspection, each transmission line has common components with unique characteristics, beginnings and ends…. Read more
Jan 08, 2018 | By Edvard Csanyi
8 Examples Of Transformer Differential Protection Using SIPROTEC Numerical Relays
The following examples show the application of SIPROTEC numerical relays for transformer protection. The individual functions are designated, using ANSI codes (Standard C37.2 – Electrical Power System Device Function Numbers)…....
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Jan 05, 2018 | By Edvard Csanyi
Solve These Ten DC Circuits and Train Your Brain!
I guess you’re still recovering from an awesome lunches and dinners you’ve had during holidays. Well, now when it’s over – it’s a good moment to plug yourself back and… Read more
Jan 04, 2018 | By Edvard Csanyi
Protection Of Industrial Power Supply Systems (Fuses, MCCBs and Overcurrent Relays Settings)
As industrial operations processes and plants have become more complex and extensive, the requirement for improved reliability of electrical power supplies has also increased. The potential costs of outage time… Read more
Jan 02, 2018 | By Edvard Csanyi
It’s About Time. Engineers, Happy New Year!
Well, it’s about time. With 2018 just around the corner, it’s time to stop and look back at yet another good year at EEP. Beside publishing about 300+ technical articles… Read more
Dec 30, 2017 | By Edvard Csanyi
3 Bad Conditions That Cause False Differential Current In Power Transformer
When applying differential protection of power transformer, three bad conditions must be considered which can lead to unbalance to the currents applied to the relay (compared with the expected currents… Read more
Dec 27, 2017 | By Edvard Csanyi
10 Common Questions You Can Expect In Electrical Engineering Examination Test
This examination will focus on testing the fundamentals of electrical engineering from low voltage to high voltage. Of course, you can use huge EEP’s resources for help in calculations and… Read more
Dec 26, 2017 | By Edvard Csanyi
This Is Why HVDC Transmission System Beats HVAC In These Essential Applications
For the most part, electric power is transmitted worldwide by means of ac. However, there are certain applications where dc transmission offers distinct economic and/or performance advantages. These applications include… Read more
Dec 21, 2017 | By Edvard Csanyi
Important Factors In Design Of Distribution Substations
Distribution substation design must be a combination of reliability and quality of the power supply, safety, economics, maintainability, simplicity of operation, and functionality. Safety of life and preservation of property… Read more
Dec 20, 2017 | By Edvard Csanyi
What does a good grounding of the power substation and switching station really mean?
Provision of adequate grounding in a substation and switching stations are very important for the safety of operating personnel as well a electrical devices do not rise above tolerable thresholds… Read more
Dec 18, 2017 | By Edvard Csanyi
Analyzing Power System And Equipment Performance Through Oscillographic Records
Most technically oriented people recognize the familiar 60Hz voltage and current traces that constitute the parameters of an operating power system. There are, however, transient components superimposed on the 60Hz…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Dec 15, 2017 | By Edvard Csanyi
Contactor As An Important Part Of The Motor Control Gear
Motor control gear and associated circuitry are fundamental parts of electrical distribution and utilisation systems. Motor control gear in its simplest form may be a direct on-line starter consisting of… Read more
Dec 15, 2017 | By Edvard Csanyi
Primary injection testing of protection system for wiring errors between VTs / CTs and relays
This type of test involves the entire circuit – current transformer primary and secondary windings, relay coils, trip and alarm circuits, and all intervening wiring are checked. There is no… Read more
Dec 13, 2017 | By Edvard Csanyi