Practical advice for positioning of circuit breakers inside LV switchboard
Mounting of the different mechanical and electrical components (enclosures, busbars, functional units – circuit breakers, etc.) which constitute the LV switchboard defined by the original manufacturer must be carried out… Read more
Aug 07, 2017 | By Edvard Csanyi
MV network diagrams for feeding secondary switchboards and MV/LV transformers
Let’s take a look at the main MV network diagrams and structures used to feed secondary switchboards and MV/LV transformers. The complexity of the diagrams differs, depending on the level… Read more
Aug 04, 2017 | By Edvard Csanyi
How to install a manual transfer switch for a backup system in 16 steps
A manual transfer switch is installed next to the main service panel to override the normal electrical service with power from a backup generator during a power outage. Manual transfer… Read more
Aug 02, 2017 | By Edvard Csanyi
Reactive power and power factor measurement in industrial plant
A varmeter is used to measure the reactive power in an industrial plant that is supplied by an 8300-V, three-phase, four-wire line. The plant load is estimated to be 300…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Jul 31, 2017 | By Edvard Csanyi
20 Simple Questions to Check Your Overcurrent Protection Knowledge
As you already know, reliable overcurrent protective devices, such as fuses and circuit breakers, prevent or minimize costly damage to transformers, conductors, motors, equipment, and the other many components and… Read more
Jul 31, 2017 | By Edvard Csanyi
3 greatest enemies to the transformer operation (and how to prevent them)
The principal object of transformer maintenance is to maintain the insulation in good condition. Moisture, dust and excessive heat are the main reasons of insulation deterioration and avoidance of these… Read more
Jul 28, 2017 | By Edvard Csanyi
Unbalance protection of grounded & ungrounded wye shunt capacitor banks
The protection of shunt capacitor banks against internal faults involves several protective devices in a coordinated scheme. Typically, the protective elements found in a shunt capacitor banks (SCB) for internal… Read more
Jul 26, 2017 | By Edvard Csanyi
Three proven ways to reduce electrical energy losses in buildings
As savings in terms of costs are the main concern for the operators, the first approach is to try to reduce electrical energy losses in buildings. Also, the electricity supply… Read more
Jul 24, 2017 | By Edvard Csanyi
What does bonding (bonded) mean and what does NEC article 250 say about it?
The National Electrical Code (NEC) covers grounding and bonding in several articles, but the primary coverage is in Article 250. Typical commercial electrical systems are grounded systems. Within the system,… Read more
Jul 21, 2017 | By Edvard Csanyi
11-step procedure for a successful electrical circuit design (LV project example)
Let’s take an example of electrical circuit design. A consumer lives in a bungalow with a detached garage and workshop, as shown in Figure 1. The building method is traditional… Read more
Jul 19, 2017 | By Edvard Csanyi
Practical solutions for preventing ferroresonance in electrical installations
Ferroresonance is a non-linear resonance phenomenon that can affect power networks. The abnormal rates of harmonics and transient or steady state overvoltages and overcurrents that it causes are often dangerous… Read more
Jul 17, 2017 | By Edvard Csanyi
Practical methods of reducing noise and interference on cables
A few practical methods of reducing noise will be examined in this technical article. These include a quantitative consideration of the effects of shielding, cable spacing, earthing (or grounding) and…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Jul 15, 2017 | By Edvard Csanyi
Easy understanding of 3-phase transformer connections (Delta–Delta, Wye–Wye, Delta–Wye and Wye–Delta)
Three-phase voltage transformations can be accomplished by using three phase transformers, which are single devices with all windings constructed on a single iron core. They also can be accomplished by… Read more
Jul 14, 2017 | By Edvard Csanyi
Automation of secondary distribution networks in rural areas
The challenges in network automation for rural areas are similar to those in urban areas, however the network topology may be very different. A typical conventional network topology is shown… Read more
Jul 12, 2017 | By Edvard Csanyi
How do faults develop in a HV transformer and why condition monitoring is important
Condition monitoring equipment that can be used to extend the life of a transformer or to prevent catastrophic failure could pay for itself many times over. However, condition monitoring does… Read more
Jul 10, 2017 | By Edvard Csanyi