Edvard Csanyi
1671 awesome technical articles
Electrical engineer, programmer and founder of EEP. Highly specialized for design of LV/MV switchgears and LV high power busbar trunking (<6300A) in power substations, commercial buildings and industry facilities. Professional in AutoCAD programming.
Main features that make AC drive the leading motor control method
We can confidently say that the AC drive is the leading motor control method. This technical article deals with a closer look at the different features of the AC drive, and… Read more
Dec 23, 2016 | By Edvard Csanyi
A case study of 110/10 kV substation with centralized protection, automation and control system
Centralized substation protection and control has been attempted in the past based on the available technology. This evolution is now at the intersection of sensing, protection and communication technologies, providing… Read more
Dec 21, 2016 | By Edvard Csanyi
Thumb rules for installing AC converter into metal enclosure
If the environmental conditions are likely to exceed normal working ranges of an AC converter, then arrangements should be made to provide additional cooling and/or environmental protection. The temperature limits… Read more
Dec 19, 2016 | By Edvard Csanyi
The basic calculation of transmission line protection
The excessive currents accompanying a fault, are the basis of overcurrent protection schemes. For transmission line protection in interconnected systems, it is necessary to provide the desired selectivity such that… Read more
Dec 16, 2016 | By Edvard Csanyi
Six wiring and grounding problems that lead to low power quality
In this technical article, typical wiring and grounding problems, as related to power quality, are presented. Possible solutions are given for these problems as well as the possible causes for the… Read more
Dec 14, 2016 | By Edvard Csanyi
Sizing of motors and frequency converters for a particular machine load
Manufacturers of electric motors and frequency converters have evolved various methods for quickly selecting the size of motors and frequency converters for a particular machine load. The same basic procedure… Read more
Dec 12, 2016 | By Edvard Csanyi
The principles of differential protection you MUST understand
Although nowadays differential protection is achieved numerically, in order to understand the principles of differential protection it is useful to analyze the ubiquitous electromechanical relay. Figure 1 shows a simple differential… Read more
Dec 09, 2016 | By Edvard Csanyi
9 rules for correct cabling of the Modbus RS485 communication systems
The cabling of the industrial communication systems (Modbus RS485) is different in some ways from the cabling used for power cabling and the electrician may experience some difficulties if he is not… Read more
Dec 07, 2016 | By Edvard Csanyi
Shaping and connecting rigid busbars in low voltage switchgear
The busbars constitute the real “backbone” of every low voltage switchgear. The main busbar and branch busbars supply and distribute the energy. Creating busbars generally involves machining, bending and shaping… Read more
Dec 05, 2016 | By Edvard Csanyi
Gas insulated substation (GIS) versus Air insulated substation (AIS)
The metal-enclosed gas insulated switchgear> inherently follows the criteria for new substation design and offers a higher reliability and flexibility than other solutions. Due to the gas enclosed design, GIS… Read more
Dec 02, 2016 | By Edvard Csanyi
What is an inductor and how it works (facts you must NEVER forget)
We have all heard the term Inductor many times, but what is it? Well, it is a passive element designed to store energy in its magnetic field. Inductors find numerous… Read more
Nov 30, 2016 | By Edvard Csanyi
Troubleshooting dead circuit by testing continuity with disconnected supply
Dead circuit testing is testing performed with the power disconnected from the circuit. The main benefit of disconnecting power supply while tests with an external energy source are performed is… Read more
Nov 28, 2016 | By Edvard Csanyi
3 good ways to improve earth electrode resistance
When you find that your earth electrode resistance is not low enough, there are several ways you can improve it: Lengthen the earth electrode in the earth Use multiple rods… Read more
Nov 25, 2016 | By Edvard Csanyi
5 transformer fault conditions and how to protect from them
A number of transformer fault conditions can arise practically in any time following some special situations. These include the following five most common internal faults and few external: earth faults,… Read more
Nov 23, 2016 | By Edvard Csanyi
Protection from fault current by automatic power supply disconnection
The use of protective conductors linking all the exposed conductive parts of all equipment creates a circuit called the “fault loop” designed for circulation of the fault current that arises… Read more
Nov 21, 2016 | By Edvard Csanyi