The fundamentals of protection relay co-ordination and time/current grading principles
Transmission and distribution systems are exposed to overcurrent flow into their elements. In an electric power system, overcurrent or excess current is a situation where a larger than intended electric… Read more
Aug 13, 2018 | By Edvard Csanyi
Generator earthing and stator earth fault protection
Generating unit is a pretty complex system made up of the generator stator winding, its transformer and unit transformer (if present), the rotor with its field winding and excitation system,… Read more
Aug 06, 2018 | By Edvard Csanyi
Current and voltage digital transformation in a modern substation protection and automation
Developments in communication have done much to realize the digital substation, but to realize a full digital substation it is necessary to have everything in digital form. Whilst much substation…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Jul 25, 2018 | By Edvard Csanyi
How to create a specific neutral earthing system within existing one (islanding)
Each neutral earthing system has advantages and disadvantages for the safety of property, electromagnetic compatibility or continuity of service. The main system must therefore be chosen according to these criteria,… Read more
Jul 18, 2018 | By Edvard Csanyi
Using full potential of IEC 61850 with these 2 functions for digital substation automation
Since IEC 61850 was published as an international standard for communication in substations, the standard has found broad acceptance on the markets. In the first substations to use it, the… Read more
Jul 04, 2018 | By Edvard Csanyi
Selection of relay for incoming and outgoing feeders for MV and LV MCC switchgear
Selection of proper relay is one of the most important stages to have a reliable network. In this article, selection of relay for incoming and outgoing feeders for LV switchgear… Read more
Jul 02, 2018 | By Edvard Csanyi
What is the digital substation and what makes it digital?
The Digital Substation is a term applied to electrical substations where operation is managed between distributed intelligent electronic devices (IEDs) interconnected by communications networks. It became possible by using computing… Read more
Jun 27, 2018 | By Edvard Csanyi
Current and voltage transformers (CTs and VTs) as protection’s eyes and ears
The CTs (current transformers) and VTs (voltage transformers) are provided in the plants to reduce the voltage and current values of the plant to values such as to be able… Read more
Jun 20, 2018 | By Edvard Csanyi
Four ways to bolster the short-circuit withstand capability of HV transformers
There are many methods applied to bolster the short circuit withstand capability of the transformers: improvement of the materials, reforming of the design and good maintenance in the operation process… Read more
Jun 13, 2018 | By Edvard Csanyi
Critical role of time synchronisation in IEC 61850 based digital protection systems
The needs and exact precision of time synchronization in IEC 61850 based digital protection systems have evolved. With new technologies and better distribution methods, most modern intelligent electronic devices (IEDs)…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Jun 08, 2018 | By Edvard Csanyi
Communications in power system protection (medias, protocols and network topologies)
A communication system consists of a transmitter, a receiver and communication channels. Type of medias and network topologies in communications provide different opportunities to advance the speed, security, dependability, and… Read more
Jun 04, 2018 | By Edvard Csanyi
What’s really important to achieve in transmission line protection relaying?
As you already know, the real purpose of transmission line protection is to detect faults or abnormal operating conditions and to initiate corrective action. Protective relays must be able to… Read more
May 21, 2018 | By Edvard Csanyi
The essential physics behind transformer differential protection (You MUST know)
Transformers are important system components available in many different constructions. The range of HV transformers reaches from small distribution transformers (from 100 kVA) up to large transformers having several hundred… Read more
May 14, 2018 | By Edvard Csanyi
The story of IEC 61850 – A substation level data acquisition architecture and communication protocol
This technical article reviews substation level data acquisition architecture and communication protocol described in IEC 61850. IEC 61850 is the current international standard for substation automation (SA). The focus of… Read more
May 09, 2018 | By Edvard Csanyi
What is the Ground Potential Rise in your home and why you should take it seriously
People familiar with electricity frequently accept the idea that “Ground is ground,” i.e., that in a house, especially with a grounding system that complies with the NEC or CEC, all… Read more
Apr 30, 2018 | By Edvard Csanyi