Seven design diagrams that every HV substation engineer MUST understand
A substation engineer should have a good understanding of the electrical equipment and layout of HV power substation. It’s also important to understand relationship between protection and the other equipment… Read more
Oct 04, 2017 | By Edvard Csanyi
Rules for power distribution in LV switchgear and protection of branch / distributed lines
Power distribution in low voltage switchgear can be defined as supplying power to a number of physically separate and individually protected circuits from a single circuit. Depending on the circuits… Read more
Sep 20, 2017 | By Edvard Csanyi
The essentials of electric shock protection, earthing systems and RCDs
Protection of persons and livestock against electric shock is a fundamental principle in the design of electrical installations in accordance with BS 7671: Requirements for Electrical Installations, commonly known as… Read more
Aug 21, 2017 | By Edvard Csanyi
5 special applications of residual current devices (RCDs)
Normally residual current devices (RCDs) are used for protection against direct and indirect contacts. An RCD can detect low leakage currents that could flow through the body of a person…. Read more
Aug 16, 2017 | By Edvard Csanyi
The essentials of MV/HV magnetic voltage transformers
Magnetic voltage transformers are used to provide a secondary signal that is proportional to the actual prevailing primary value. These signals are used to supply measuring instruments, meters, relays and… Read more
Aug 14, 2017 | By Edvard Csanyi
The most common methods of measuring the resistance of an earth electrode
When an earth electrode system has been designed and installed, it is usually necessary to measure and confirm the earth resistance between the electrode and “true Earth”. The most commonly… Read more
Aug 09, 2017 | By Edvard Csanyi
How to install a manual transfer switch for a backup system in 16 steps
A manual transfer switch is installed next to the main service panel to override the normal electrical service with power from a backup generator during a power outage. Manual transfer… Read more
Aug 02, 2017 | By Edvard Csanyi
20 Simple Questions to Check Your Overcurrent Protection Knowledge
As you already know, reliable overcurrent protective devices, such as fuses and circuit breakers, prevent or minimize costly damage to transformers, conductors, motors, equipment, and the other many components and… Read more
Jul 31, 2017 | By Edvard Csanyi
Unbalance protection of grounded & ungrounded wye shunt capacitor banks
The protection of shunt capacitor banks against internal faults involves several protective devices in a coordinated scheme. Typically, the protective elements found in a shunt capacitor banks (SCB) for internal… Read more
Jul 26, 2017 | By Edvard Csanyi
What does bonding (bonded) mean and what does NEC article 250 say about it?
The National Electrical Code (NEC) covers grounding and bonding in several articles, but the primary coverage is in Article 250. Typical commercial electrical systems are grounded systems. Within the system,… Read more
Jul 21, 2017 | By Edvard Csanyi
The basics of capacitor banks protection
As you already know, capacitor banks are normally used in medium voltage networks to generate reactive power to industries etc. Capacitor banks are, almost always, equipped with a series reactors… Read more
Jul 07, 2017 | By Edvard Csanyi
Practice for good grounding and bonding a home wiring system
All home electrical systems must be bonded and grounded according to code standards. This entails two tasks: First, the metal water and gas pipes must be connected electrically to create… Read more
Jun 19, 2017 | By Edvard Csanyi
Pre-commissioning tests and in-service checks of protection system
The pre-commissioning tests need to be carefully programmed so that they take place in a logical and efficient order, in order that no equipment is disturbed again during subsequent tests…. Read more
Jun 14, 2017 | By Edvard Csanyi
Philosophy of a good relay protection settings for machines and plants
The objectives of the protection system are: to limit damage to people and to the plant, permit different service conditions, guarantee maximum service continuity for the plant not affected by faults and activate the automatisms… Read more
Jun 09, 2017 | By Edvard Csanyi
How backup protection is used to improve fault-clearing system in HV networks
All elements in the fault-clearing system do not always operate correctly. Protection relays may fail to operate or may operate unwantedly. Switching devices may fail to interrupt the fault current…....
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Limited time offer! - Save 15% on Pro Membership Plan with discount code LRN15
Log In »Purchase »
Jun 05, 2017 | By Edvard Csanyi