Archive: Category «Transformers»

Protection

The Purpose Of Transformer Gas Relay

The transformer gas relay is a protective device installed on the top of oil-filled transformers. It performs two functions. It detects the slow accumulation of gases, providing an alarm after… Read more

Nov 29, 2012 | By Edvard Csanyi

The Purpose Of Transformer Gas Relay
Protection

Transformer Differential Protection Principles

Similar to bus protections, transformers are protected by differential relays. Inter-winding faults (short circuits) and ground faults within power transformers can be detected by this protection scheme. Failure to detect… Read more

Nov 01, 2012 | By Edvard Csanyi

Transformer Differential Protection Principles
Transformers

Transformers Are Never Silent

Yes, we all know that transformers are never silent. This is actually quite impossible, but in an environmentally aware, highly regulated world, the issue is not the level of noise,… Read more

Oct 29, 2012 | By Edvard Csanyi

A three-phase oil transformer 225 MVA, 275 kV
Energy and Power

Safety Clearance Recommendations for Transformer

Clearance from Outdoor Liquid Insulated Transformers to Buildings (NEC) Clearance between Two Outdoor Liquid Insulated Transformers (NEC) Dry Type Transformer in Indoor Installation (NES 420.21) Dry Type Transformer in Outdoor… Read more

Oct 24, 2012 | By jiguparmar

Safety Clearance Recommendations for Transformer
Transformers

Definitions of Voltage Transformer Parameters

Rated voltage factor Rated primary voltage (Up) Rated secondary voltage Accuracy power Accuracy class Voltage ratio error Phase or phase displacement error Rated thermal limiting output The voltage transformer must… Read more

Oct 18, 2012 | By Edvard Csanyi

Definitions of the Voltage Transformer Parameters
Transformers

Heating of the Dry-type Transformer

Although transformers can be classified by core construction (shell or core type), the more functional types of standardized classifications are based on how the transformer is designed for its specific… Read more

Oct 15, 2012 | By Edvard Csanyi

Heating of the Dry-type Transformer
Power Substation

Switching Impulse Test of the Transformer

The switching impulse test is applied to confirm the withstand of the transformer’s insulation against excessive voltages occurring during switching. During the switching impulse voltage test, the insulation between windings… Read more

Oct 11, 2012 | By Edvard Csanyi

Switching Impulse Test of the Transformer
Protection

Overcurrent protection of transformer (NEC 450.3)

The overcurrent protection required for transformers is consider for Protection of Transformer only. Such overcurrent protection will not necessarily protect the primary or secondary conductors or equipment connected on the… Read more

Oct 08, 2012 | By jiguparmar

Overcurrent protection of transformer (NEC 450.3)
Transformers

Dry Transformer Percent Impedance Definition

The percent impedance is the percent voltage required to circulate rated current flow through one transformer winding when another winding is short-circuited at the rated voltage tap at rated frequency. %Z is related… Read more

Oct 03, 2012 | By Edvard Csanyi

Dry Transformer Percent Impedance Definition
Transformers

Right Choice of Dry Type or Liquid-Filled Transformer

1. Two Types of Transformers 2. Cooling and insulating system 3. Losses 4. Operating Life of Transformer 5. Maintainability 6. Repairability 7. Core/Coil Reclamation and Recycling 8. Operating Sound Level… Read more

Sep 29, 2012 | By Edvard Csanyi

Right Choice of Dry Type or Liquid-Filled Transformer
Energy and Power

Transformer Heat, Copper and Iron Losses

The thermal ratings of a transformer are determined by the following three factors: The amount of heat produced in the windings and connections. The amount of heat produced in the… Read more

Sep 06, 2012 | By Edvard Csanyi

Transformer Heat, Copper and Iron Losses
Protection

Transformer differential protection (ANSI 87T)

Transformer differential protection protects against short-circuits between turns of a winding and between windings that correspond to phase-to-phase or three-phase type short-circuits. If there is no earthing connection at the… Read more

Sep 05, 2012 | By Edvard Csanyi

SIPROTEC 4 7UT6 Differential Protection Relay for Transformers
Power Substation

Transformers Connected Directly to Generators

Power transformers connected directly to generators can experience excitation and short-circuit conditions beyond the requirements defined by ANSI/IEEE standards. Special design considerations may be necessary to ensure that a power transformer… Read more

Sep 01, 2012 | By Edvard Csanyi

Generator transformer


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge