Electric motors – and how to improve their control, protection

Economic reasons

Nowadays, apart from lighting devices, electric motors represent the largest loads in industry and commercial installations. Their function, to convert electrical energy into mechanical energy, means they are particularly significant in economic terms, and hence, they cannot be ignored by installation or machinery designers, installers or users.

There are many types of motor in existence, but 3-phase asynchronous motors, and in particular squirrel cage motors, are the most commonly used in industry and in commercial buildings applications above a certain power level. Moreover, although they are ideal for many applications when controlled by contactor devices, the increasing use of electronic equipment is widening their field of application. This is the case for start/stop control with soft start/soft stop units, and when precise speed adjustment is also necessary with variable speed drives/regulators.

However, slip-ring asynchronous motors are used for certain high power applications in industry, and single phase asynchronous motors remain suitable for limited power applications, mainly for buildings applications. The use of synchronous motors, known as brushless or permanent magnet motors, combined with converters is becoming increasingly common in applications requiring high performance levels, in particular in terms of dynamic torque (on starting or on a change of duty), precision and speed range.

After presenting the various types of electric motor and their operating principles, this “Cahier Technique” describes the technical and operating features of asynchronous motors, covering in particular the main starting devices, speed control and braking methods. It provides a solid grounding for the reader to gain a good understanding of all the problems involved with motor control and protection.

This “Cahier Technique” touches briefly on variable speed control of electric motors. However, this subject is covered more specifically in “Cahier Technique” CT 208 “Electronic starters and variable speed drives“. Motor protection is the subject of another “Cahier Technique” currently in preparation.

AUTHOR: Schneider Electric expert | Etienne GAUCHERON

Title:Electric motors… and how to improve their control and protection
Format:PDF
Size:0.4MB
Pages:25
Download:Please login first

Electric motors... and how to improve their control and protection


Subscribe to Monthly Download Updates

Don't miss anything!

Get EEP's updates without having to keep checking up on the portal to see if there is anything new. New FREE technical articles, electrical books, guides, software and other exclusive content you will receive via email. Pretty simple!

Powered by MailChimp

Write for EEP, become contributor | Introduce yourself to huge number of our readers


2 Comments


  1. khaledsalah
    May 05, 2011

    there is problem in this link


    • Edvard
      Jun 13, 2011

      Just tried to download and it seems it’s working just fine. Please check again!

Leave a reply!

You must be logged in to post a comment.

Tell us what you're thinking... we care about your opinion!
and oh, not to forget - if you want a picture to show with your comment, go get a free Gravatar!

Subscribe to free EEP’s updates

Subscribe to Monthly Download Updates:

(free electrical software, engineering guides and books)

Subscribe also to EE Technical Articles

Engineering Trainings

Top EEP’s Technical Writers

Technical Categories

Recommended to read and FREE download:
Setting the scene in UK – Why renewable energy?

Energy is at the heart of our society. To date, the developed world has relied predominantly on fossil fuels (coal,...

History of the development of busbar protection

Up to the mid 1930′s, no widescale efforts had been made to protect busbars on a unit basis. Also there...

Automation Solution Guide

Abstract Progress in industrial automation has helped industry to increase its productivity and lower its costs. Widespread use of electronics...

Close