Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Principles of Energy Management

Maintaining a reliable supply of electrical power to consumers is a highly complex process as most of this power cannot be stored and the individual components of this process, forming what is called a power system, can be spread over a wide geographical area. The purpose of power system management, also referred to as Energy Management, is to monitor, control and optimize this process in real-time.

Design, development and implementation of SCADA application software
Design, development and implementation of SCADA application software (photo credit: Wonderware)

The basic functionality of power system control is found in the Supervisory Control and Data Acquisition (SCADA) function that collects and records values and statuses acquired from the power system elements via remote telemetry to enable control center operators to supervise and control the power system.

Other decision support functions complement this function to provide power system management for a secure and optimal process (figure 1).

Power control systems – serving the complete energy chain from generation to load
Figure 1 – Power control systems – serving the complete energy chain from generation to load

The Role of the Network Control System in Power System Management

History

The control and information technology used for the management of a power system has its origins in the automation of power plants. The primary objective was then to improve operational reliability (Figure 2).

With the increasing number of power plants and their interconnection via the grid, primary frequency control, also referred to as generator droop control, was no longer sufficient. To improve on power delivery quality, coordination, including secondary frequency control, of power generation and, later, external interchange became unavoidable and was promptly implemented in control centers.

Before the introduction of the transistor in 1947, the vast majority of protection and control devices used in power system control were of electromechanical design.

Todays’ operator user interface of a large power control system
Figure 2 – Todays’ operator user interface of a large power control system

In the early days, information was transmitted by means of relays and pulse techniques, but with the introduction of electronics it became possible to implement increasingly efficient transmission means. At the end of the 1960s, with the introduction of the first process control computer, the first computer assisted power and frequency control systems became possible.

As computers became more efficient in the 1970s, the switchgear in transmission networks was also gradually monitored and automated with the aid of power system control technology.

In response to the growing demand for network control systems, a number of companies began developing standardized systems for these applications. The systems of that period can be called the first generation of network control systems.

Because of the inadequate graphics capability of computer terminals at that time, the master computers were used mainly for remote monitoring of unmanned stations or for performing calculations to support operations. The network state was displayed visually on large switch panels or mosaic walls that were also used to control the switchgear.

Only as the performance of graphical displays improved were Operation management functions gradually transferred to VDU-based Workstations.

As computing power continued to increase in the mid-1970s, it also became possible to use computers for optimization processes.

With the aid of optimization programs run initially as batch Jobs and later online as well, it was possible, for instance, to determine the most economical use of hydroelectric and thermal power plants.

These programs also provided a method of economically assessing the exchange of energy, a basic requirement for energy trading later on. Increasing computer power was, however, also harnessed to further develop man-machine communication towards greater user friendliness.

Title:Energy Management – SIEMENS
Format:PDF
Size:1.93 MB
Pages:40
Download:Right here | Video Courses | Membership | Download Updates
Energy Management Guide - SIEMENS
Energy Management Guide – SIEMENS

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount - Save 50% on all 110+ video courses with Enterprise Membership plan.

More Information

3 Comments


  1. Sonny Ramos
    May 18, 2015

    I can’t download th white paper. Thanks


  2. LADJEL Loukmane
    Apr 06, 2014

    I can’t get acces to the articles or download them I would like some help if it’s possible.Thanx

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.