Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Smart grids

A secure, reliable and economic power supply is closely linked to a fast, efficient and dependable communication infrastructure. Planning and implementation of communication networks require the same attention as the installation of the power supply systems themselves (fig.1).

Communication network solutions guide for smart grids
Communication network solutions guide for smart grids

Telecommunication for utilities has a long history in the transmission level of the power supply system and Siemens was one of the first suppliers of communication systems for power utilities. Since the early 1930s Siemens has delivered Power Line Carrier equipment for high-voltage systems. In today’s transmission systems, almost all substations are monitored and controlled online by Energy Management Systems (EMS).

The main transmission lines are usually equipped with fiber-optic cables, mostly integrated in the earth (ground) wires (OPGW: Optical Ground Wire) and the substations are accessible via broadband communication systems.

The two proven and optimal communication technologies for application-specific needs are Synchronous Digital Hierarchy (SDH) and Ethernet.

Fiber-optic cables are used whenever it is cost-efficient. In the remote ends of the power transmission system, however, where the installation of fiber-optic cables or wireless solutions is not economical, substations are connected via digital high-voltage power line carrier systems.

Figure 1 - Complete communication network solutions to build a Smart Grid for power utilities
Figure 1 – Complete communication network solutions to build a Smart Grid for power utilities

The situation in the distribution grid is quite different. Whereas subtransmission and primary substations are equipped with digital communication as well, the communication infrastructure at lower distribution levels is very weak.

In most countries, less than 10 % of transformer substations and ring-main units (RMU) are monitored and controlled from remote.

The rapid increase in distributed energy resources today is impairing the power quality of the distribution network. That is why system operators need to be able to respond quickly in critical situations.

A prerequisite for this is the integration of the key ring-main units as well as the volatile decentralized wind and solar generation into the energy management system, and thus into the communication network of the power utilities.

Because the local environment differs widely, it is crucial that the right mix of the various communication technologies is deployed.

This mix will need to be exactly tailored to the utilities’ needs and the availability of the necessary infrastructure and resources (e.g., availability of fiber-optic cables, frequency spectrum for wireless technologies, or quality and length of the power cables for broadband power line carrier).

Title:Network Solutions for Smart Grids – SIEMENS
Format:PDF
Size:1.51 MB
Pages:36
Download:Right here | Video Courses | Membership | Download Updates
SIEMENS - Network Solutions for Smart Grids
SIEMENS – Network Solutions for Smart Grids

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount - Save 50% on all 110+ video courses with Enterprise Membership plan.

More Information

8 Comments


  1. Asan Masraf
    Jan 08, 2024

    Thanks in advance.
    I was wondering if there is any other useful documents similar to this one, I will be appreciated if some one share it with me for my next research topic paper.


  2. farrukh
    May 07, 2014

    today my teacher advised me to do my final year project on smart grid and when i open my mail box i have seen this pdf thans a lot EE Portal for such a nice info…. :)


    • Edvard
      May 07, 2014

      Great! Hope you will find it usefull!


  3. pieter
    May 06, 2014

    looking forward to the info


  4. Andre Silva
    Apr 24, 2014

    Very good articles. Check it on a daily basis.

    Keep up the good work!


  5. ali
    Apr 24, 2014

    Thanks a lot!

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.