Site Conditions Impact on Caterpillar Genset Ratings
An engine rating is primarily limited by structural and thermal limits. These limits include maximum cylinder pressure during combustion, turbocharger speed, exhaust gas temperature and in natural gas engines, fuel type. Where an engine operates relative to these limits will determine the maximum altitude and ambient… Read more
Aug 17, 2012 | By Edvard Csanyi
The major components of an Air Circuit Breaker and the Arc Interruption
The basic characteristics for air magnetic circuit breakers are maximum rationalization and constructional simplicity. The major components of such breakers are: the poles, the arc chutes, the base frame, the operating mechanism. The operating mechanism construction and parts are similar to that of… Read more
Jul 25, 2012 | By Edvard Csanyi
Insulating materials in electrical equipment
The reason for using insulating materials is to separate electrically the conducting parts of equipment from each other and from earthed components. Earthed components may include the mechanical casing or structure that is necessary to enable the equipment to be… Read more
Oct 05, 2011 | By Edvard Csanyi
Maintenance Of Meduim Voltage Circuit Breakers
Medium-voltage circuit breakers rated between 1 and 72 kV may be assembled into metal-enclosed switchgear line ups for indoor use, or may be individual components installed outdoors in a substation. Air-break circuit breakers replaced oil-filled units for indoor applications, but… Read more
Apr 17, 2011 | By Edvard Csanyi
Maintenance Of Low Voltage Circuit Breakers
The deterioration of low voltage circuit breaker is normal and this process begins as soon as the circuit breaker is installed. If deterioration is not checked, it can cause failures and malfunctions. The purpose of an electrical preventive maintenance and… Read more
Dec 31, 2010 | By Edvard Csanyi
Aerodynamics of Horizontal-Axis Wind Turbines
A wind turbine is a device for extracting kinetic energy from the wind. By removing some of its kinetic energy the wind must slow down but only that mass of air which passes through the rotor disc is affected. Assuming… Read more
Dec 06, 2010 | By Edvard Csanyi
Transformer Cooling Classes
Since no transformer is truly an “ideal” transformer, each will incur a certain amount of energy loss, mainly that which is converted to heat. Methods of removing this heat can depend on the application, the size of the unit, and… Read more
Nov 28, 2010 | By Edvard Csanyi