Technical Articles Tagged With 'construction'

Energy and Power

Rogowski Coil Construction

Figure 1 shows the construction of a Rogowski coil, an air-core current transformer that is especially well suited to measuring ripple currents in the presence of a DC component or measuring pulsed currents. The raw output is proportional to the… Read more

Dec 13, 2012 | By

Rogowski Coil Construction
Transformers

Power Transformer Construction – The Core

The construction of a power transformer varies throughout the industry. The basic arrangement is essentially the same and has seen little significant change in recent years, so some ofthe variations can be discussed in this article. The core, which provides… Read more

Aug 23, 2012 | By

Power Transformer Construction - Core
Electric Motor

Synchronous Motor Construction

Synchronous motors convert electrical power to mechanical power and synchronous generators convert mechanical power to electrical power; and synchronous condensers supply only reactive power to stabilize system voltages. Synchronous motors, generators, and condensers perform similarly, except for a heavy cage winding on the… Read more

Jan 14, 2012 | By

Synchronous Motor Construction
High Voltage

Construction and service life of GIS

GIS is assembled of standard equipment modules (circuit breaker, current transformers, voltage transformers, disconnect and ground switches, interconnecting bus, surge arresters, and connections to the rest of the electric power system) to match the electrical one-line diagram of the substation…. Read more

Jun 04, 2011 | By

Figure 2.1 Single-phase enclosure GIS
Power Substation

Relationship Between Earthquakes And Substations

To secure and protect substation equipment from damage due to a seismic event, the relationship between earthquakes and substation components must first be understood. Earthquakes occur when there is a sudden rupture along a preexisting geologic fault. Shock waves that… Read more

Jan 09, 2011 | By

Earthquakes And Substations
News

Introducing EEP

Hi to everyone, we are working hard on EEP, which is by the way supported by CsanyiGroup – also electrical engineering portal. Content will be similar like CsanyiGroup’s, but with much more style and funcionality. So far, we will first… Read more

Sep 16, 2010 | By

EEP - Electrical Engineering Portal


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.