Three most common SCADA applications in MV/LV distribution systems you SHOULD know
Electrical distribution systems comprise a large number of remote applications and locations, and it has traditionally been challenging to monitor and regulate these remote applications and sites. Utility companies have been installing remote terminal/telemetry units, often known as RTUs, at…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
May 08, 2023 | By Edvard Csanyi
The most common failure modes of electrical equipment in distribution systems
Each piece of electrical equipment on a distribution system has a probability of failing. When first installed, a piece of equipment can fail due to poor manufacturing, damage during shipping, or improper installation. Healthy equipment can fail due to extreme… Read more
May 10, 2021 | By Edvard Csanyi
The essentials of automation applied to distribution systems via PLCs, SCADA, IEDs, and RTUs
Nowadays, it seems that everything we do tends to be somehow automated. The very same is happening in electrical distribution systems. The distribution system at the medium voltage (MV) or low voltage (LV) levels is designed using different structures such… Read more
Mar 15, 2021 | By Edvard Csanyi
Minimizing failure impact in distribution systems by allowing faults to clear themselves
Distribution systems are basically insecure – failure of a major component always leads to customer interruptions. So, what can be done? Reliable distribution systems minimize this impact by allowing faults to clear themselves, by minimizing the number of customers affected… Read more
Apr 08, 2019 | By Edvard Csanyi
Why more and more automation in power distribution? Aren’t we already automated?
One may wonder why is everybody talking more and more about automation in power distribution. Aren’t we already automated? Well, we are not. It can always be better, faster, with more possibilities and more optimized. This is something that pushes…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Feb 28, 2019 | By Edvard Csanyi
Four essential ingredients of an electrical power system
Generally speaking, you must agree that electrical power system is a complex project consisting of the four main ingredients. Now, let’s observe each ingridient in details: Electricity supply Transmission Distribution Loads All countries now have available some supplies of electricity… Read more
Dec 30, 2016 | By Edvard Csanyi
Dimensioning of Power Distribution Systems (1)
When the basic supply concept for the electricity supply system has been established, it is necessary to dimension the electrical power system. Dimensioning means the sizing rating of all equipment and components to be used in the power system. In… Read more
Jan 20, 2014 | By Edvard Csanyi
Important in role of capacitors in distribution systems
Should the voltage on a circuit fall below a specified level for some reason, a device called a capacitor can momentarily maintain the voltage at line value. Basically, a capacitor serves the same purpose as a storage tank in a… Read more
Nov 27, 2013 | By Edvard Csanyi
How Distribution Systems Control Customer Loads?
Distribution systems obviously exist to supply electricity to end users, so loads and their characteristics are important. Utilities supply a broad range of loads, from rural areas with load densities of 10 kVA/mi2 to urban areas with 300 MVA/mi2. A… Read more
Dec 10, 2012 | By Edvard Csanyi
Primary Distribution Voltage Levels
Most distribution voltages are between 4 and 35 kV. In this article, unless otherwise specified, voltages are given as line-to-line voltages; this follows normal industry practice, but it is sometimes a source of confusion. The four major voltage classes are… Read more
Aug 10, 2012 | By Edvard Csanyi
North American versus European distribution systems
Distribution systems around the world have evolved into different forms. The two main designs are North American and European. For both forms, hardware is much the same: conductors, cables, insulators, surge arresters, regulators, and transformers are very similar. Both systems… Read more
Nov 17, 2011 | By Edvard Csanyi
Types Of Electrical Power Distribution Systems You Should Know About
Electrical power is distribution either three wires or four wires (3 wire for phases and 1 wire for Neutral). Voltage between phase to phase called Line Voltage and voltage between phase and neutral is called Phase Voltage. This forth wire… Read more
Sep 19, 2011 | By Jignesh Parmar
What is the cost of electricity?
Electrification in the early 20th century dramatically improved productivity and increased the well-being of the industrialized world. No longer a luxury – now a necessity – electricity powers the machinery, the computers, the health-care systems, and the entertainment of modern… Read more
Nov 02, 2010 | By Edvard Csanyi