Four abnormal operating conditions of a generator that could shut down the power plant
To be clear, the generator is very simple in construction and yet very complicated in operation rotating equipment. In a power plant, a generator cannot be considered in isolation because of a very large number of other equipment connected to…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Sep 06, 2021 | By Edvard Csanyi
Transformer no-load loss and excitation-current measurements
A transformer dissipates a constant no-load loss as long as it is energized at constant voltage, 24 h a day, for all conditions of loading. This power loss represents a cost to the user during the lifetime of the transformer…. Read more
Mar 27, 2019 | By Edvard Csanyi
How a three-phase power transformer responds to harmonics
The way in which a three-phase transformer responds to harmonics depends on the connection configuration used. For a star-star configuration, any imbalance in the phase currents results in the star point being electrically displaced and the phase to neutral voltages… Read more
Feb 15, 2017 | By Edvard Csanyi
Take into account these losses when purchasing power transformer
Losses and purchase price should be considered when deciding which transformer to purchase. The purpose of this technical article is to present a uniform approach that can be used to determine the dollar value of these losses over the life of the transformer…. Read more
Jun 26, 2015 | By Edvard Csanyi
What affects the operating temperature within LV switchgear
BS EN 60439 states a maximum indoor ambient temperature of 40ºC, a maximum daily average of 35ºC and a minimum ambient of -5ºC. As a general guidance rule, the temperature within the low voltage switchgear should not exceed 50/55ºC. If… Read more
Apr 30, 2014 | By Edvard Csanyi
NEMA Definition Of Motor Full Load Nominal Efficency (Standard MG1-12.54.2)
Efficiency is defined as the ratio of the power output divided by the power input. Machine losses are in the form of heat, and include: Stator winding loss, Rotor loss, Core loss (hysteresis and eddy current), Friction and windage, and… Read more
Aug 02, 2013 | By Edvard Csanyi
Transformer Extra Losses Due To Harmonics
Non-linear loads, such as power electronic devices, such as variable speed drives on motor systems, computers, UPS systems, TV sets and compact fluorescent lamps, cause harmonic currents on the network. Harmonic voltages are generated in the impedance of the network… Read more
Jun 22, 2012 | By Edvard Csanyi
Internal losses that reduce efficiency of a DC generator
There are four internal losses that contribute to lower efficiency of a DC generator. Copper losses Eddy-current losses Hysteresis losses Mechanical losses Copper loss is the power lost as heat in the windings; it is caused by the flow of… Read more
Feb 03, 2012 | By Edvard Csanyi
What is the Eddy Current?
Cant see this video? Click here to watch it on Youtube. Eddy currents are currents induced in conductors to oppose the change in flux that generated them. It is caused when a conductor is exposed to a changing magnetic field… Read more
Oct 13, 2011 | By Edvard Csanyi