Technical Articles Tagged With 'electrical'

Electrical Lectures

Fundamental Concepts of Insulation Testing

Probably 80% of all testing performed in electrical power systems is related to the verification of insulation quality. This technical article briefly describes the fundamental concepts of insulation testing including – insulation behavior, types of tests, and some test procedures…. Read more

Jul 07, 2012 | By

Fundamental concepts of insulation testing
Energy and Power

Overview Of Electrical Loads In Building

The electrical design professional should determine a building’s electrical load characteristics early in the preliminary design stage of the building to select the proper power distribution system and equipment having adequate power capacity with proper voltage levels, and sufficient space… Read more

Apr 27, 2012 | By

Low voltage switchgear type 'OKKEN' - Schneider Electric
Energy and Power

Single-Phase Power vs Three-Phase Power

The principal elements of an electric power system are the generating stations, the transmission lines, the substations, and the distribution networks. The generators produce the electricity, the transmission lines move it to regions where it is consumed, and the substations… Read more

Apr 01, 2012 | By

Single-Phase Power vs Three-Phase Power - Differences
Electric Motor

Cooling and Ventilation of Electric Motors (IC)

All rotating electrical machines generate heat as a result of the electrical and mechanical losses inside the machine. Losses are high during starting or dynamic braking. Also, losses usually increase with increased loading. Cooling is necessary to continuously transfer the… Read more

Aug 08, 2011 | By

Cooling and ventilation of electric motors (IC)
Transformers

GEAFOL – cast-resin transformer

The Siemens’s transformer GEAFOL principle has succeeded in producing transformers with excellent electrical, mechanical and thermal characteristics, which have also proved to be particularly compatible with the environment. GEAFOL transformers are insulated with an epoxy resin/quartz powder mixture. This is… Read more

May 27, 2011 | By

Siemens's cast-resin transformer 'GEAFOL'
Energy and Power

Historical Review of Power System Stability Problems

As electric power systems have evolved over the last century, different forms of instability have emerged as being important during different periods. The methods of analysis and resolution of stability problems were influenced by the prevailing developments in computational tools,… Read more

Dec 08, 2010 | By

Historical Review of Power System
Energy and Power

Electrical Power System Overcurrents

Electrical power systems must be designed to serve  a variety of loads safely and reliably. Effective  control of short-circuit current, or fault current as  it is commonly called, is a major consideration  when designing coordinated power system protection.  In order… Read more

Nov 27, 2010 | By



Learn How to Design Power Systems