Never let an electric motor drop dead. Learn how to listen and read the motor’s soul.
Like any other machine, electric motors are vulnerable to faults, which might lead to catastrophic failure of the machine in the long run if left unmonitored. In this technical article, I will try to shed some light on the possible…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Nov 29, 2021 | By Rahmatullah Alam
My worst experience in testing and commissioning power transformers (and how I fixed things up)
Reliable and secure electric power delivery is dependent on power transformers’ reliability that is enhanced significantly by sound test plans. These test plans shall be prepared by both manufacturers and end-users to develop thorough and effective plans and specifications. The…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Spring Gift! - 20% Off on Pro Membership Plan with coupon 110KVAC
Upgrade
Apr 29, 2021 | By Salem Alshahrani
Electricity and water do not form a happy partnership, do they?
Electricity and water do not form a happy partnership and so it is often necessary to “dry out” insulation. This may be done to remove surface moisture or perhaps to drive moisture from the internals of the insulation. Indeed some… Read more
Jul 13, 2016 | By Edvard Csanyi
4 Things Soil Resistivity Depends On
Though the ground itself being a very large body can act as an infinite sink for currents flowing into it and can be considered to be having very low resistance to current flow, the resistance of soil layers immediately adjacent to the… Read more
Oct 17, 2015 | By Edvard Csanyi
What to do if transformer has an excessive moisture content
The term “moisture” in the transformer industry is commonly used to indicate water which is absorbed in the paper or dissolved in the oil. Occasionally, the terms “water” or “water content” are used as an alternative way to describe the… Read more
Apr 24, 2015 | By Edvard Csanyi
2 Most Common Contributing Factors In Motor Insulation Failure
The most frequent failure in electrical equipment is the degradation and breakdown (flashover) of the insulation. Electrical insulation can be liquid or solid, organic or inorganic. Organic insulation material consists of: enamels, varnishes, resins, or polymers that are applied to the steel surface to provide… Read more
Jun 25, 2014 | By Edvard Csanyi
Why is continuous on-line monitoring of partial discharge in the switchgear necessary?
Not sure? You know that periodical maintenance test like partial discharge test can still leave switchgear in virtually unknown condition. Insulation defects and deterioration may very well develop in service within maintenance cycle. These defects are often not detectable with… Read more
Jun 16, 2014 | By Edvard Csanyi
How to measure insulation resistance of a motor
If the motor is not put into operation immediately upon arrival, it is important to protect it against external factors like moisture, high temperature and impurities in order to avoid damage to the insulation. Before the motor is put into… Read more
Jun 09, 2014 | By Edvard Csanyi
Purpose and maintenance of transformer bushings
The two most common types of bushings used on transformers as main lead entrances are solid porcelain bushings on smaller transformers and oil-filled condenser bushings on larger transformers. Solid porcelain bushings consist of high-grade porcelain cylinders that conductors pass through…. Read more
Feb 05, 2012 | By Edvard Csanyi
Moisture Effect On Insulation Of Generator
Moisture, which can enter the insulation of a generator or motor winding from damp air or which can enter the winding of a transformer from wet oil, will make a surprisingly large difference in the insulation resistance. This is clearly… Read more
May 13, 2011 | By Edvard Csanyi
Keeping Motor Windings Dry
Special provision should be made to protect motor windings which operate in a damp atmosphere or are subject to condensation of moisture when out of service for long periods. Motors located in galleries of dams are frequently subject to continual… Read more
Dec 14, 2010 | By Edvard Csanyi