Technical Articles Tagged With 'test'

Energy and Power

Inspection and Test Procedures for Metal-Enclosed Busways

Visual and Mechanical Inspection Electrical Tests Test Values Test Values – Visual and Mechanical Test Values – Electrical Tables: TABLE 100.12 – US Standard Fasteners Bolt-Torque Values for Electrical Connections TABLE 100.1 – Insulation Resistance Test Values Electrical Apparatus and… Read more

Dec 22, 2012 | By

Inspection and Test Procedures for Metal-Enclosed Busways
Power Substation

Switching Impulse Test of the Transformer

The switching impulse test is applied to confirm the withstand of the transformer’s insulation against excessive voltages occurring during switching. During the switching impulse voltage test, the insulation between windings and between winding and earth and withstand between different terminals… Read more

Oct 11, 2012 | By

Switching Impulse Test of the Transformer
Medium Voltage

Field Inspection of New Medium-Voltage Switchgear

Step Description of what you should do 1.1 Check switchgear assembly for alignment, levelness, and tightness of all bolting. 1.2 Check all equipment for the removal of blocking, supports, temporary ties, and temporary jumper wires. 1.3 Check control power transformer… Read more

Jul 16, 2012 | By

DNF7 40.5kV Medium-voltage switchgear field inspection (In Schneider Electric factory)
Energy and Power

Commissioning of Electrical Equipment

To verify system condition after has been energized with rated system (service) voltage for which it is designed. Also to ensure the protection, metering system for correct directionality. Multimeter Phase angle meter Phase sequence meter Communication software (if required) Before… Read more

Jun 25, 2012 | By

Commissioning of Electrical Equipment (on photo OKKEN Low Voltage Switchgear - Schneider Electric)
Electric Motor

Measurement of insulation resistance (IR) – Part 2

This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more

Apr 29, 2012 | By

Fluke insulation resistance tester up to 10kV
Electrical Lectures

Inspection Of Voltage Drop In Conductors

It is part of the inspection process to ensure that installed conductors have been correctly selected for current carrying capacity and voltage drop. To check the suitability of the current carrying capacity it is simply a matter of looking at… Read more

Apr 15, 2012 | By

Inspection Of Voltage Drop In Conductors
Energy and Power

Megger Insulation Resistance Test

As you know good insulation has high resistance and poor insulation relatively low resistance. The actual resistance values can be higher or lower, depending upon such factors as the temperature or moisture content of the insulation (resistance decreases in temperature… Read more

Mar 13, 2012 | By

Megger Insulation Resistance Test


Learn How to Design Power Systems