Technical Articles

Smart Grid

Smart Grid Communications Overview

An electricity grid without adequate communications is simply a power “broadcaster.” It is through the addition of two-way communications that the power grid is made “smart.” Smart grid communications enables… Read more

Jun 09, 2012 | By Edvard Csanyi

Solutions for powerline, wireless, and serial communications
Energy and Power

MCB – Miniature Circuit Breaker Construction

The miniature circuit breaker (MCB) plays an important role in providing overcurrent protection and a disconnect means in electrical networks. Recent advancements in circuit breaker technology has increased breaker performance and protection…. Read more

Jun 07, 2012 | By Edvard Csanyi

MCB - Miniature circuit breaker construction
Electrical Lectures

Fundamental Characteristics of Circuit Breaker

The fundamental characteristics of a circuit breaker are: Its rated voltage Ue Its rated current In Its tripping current level adjustment ranges for overload protection (Ir or Irth) and for short… Read more

Jun 05, 2012 | By Edvard Csanyi

Fundamental characteristics of circuit breakers
Energy and Power

Understanding Vector Group of Transformer (2)

Continued from first part Understanding Vector Group of Transformer (part 1) Vector Groups are the IEC method of categorizing the primary and secondary winding configurations of 3-phase transformers. Windings can… Read more

Jun 04, 2012 | By jiguparmar

220kV Class 110kV Class Single Phase Traction Transformer
Electrical Lectures

Understanding Vector Group of Transformer (Part 1)

Three phase transformer consists of three sets of primary windings, one for each phase, and three sets of secondary windings wound on the same iron core. Separate single-phase transformers can… Read more

Jun 03, 2012 | By jiguparmar

Understanding Vector Group of Transformer (Part 1)
Industrial Automation

Using MODBUS for Process Control and Automation (2)

To communicate with a slave device, the master sends a message containing: Device Address Function Code Data Error Check Continued from first part of article Using MODBUS for Process Control… Read more

May 31, 2012 | By Edvard Csanyi

The Schneider Electric Modicon Quantum is a versatile PLC
Smart Grid

Electric Vehicles and the Smart Grid

Another source of urgency for the smart grid is meeting goals for getting more “clean” cars and vehicles on the road. Electric vehicles largely eliminate greenhouse gas emissions from vehicle… Read more

May 30, 2012 | By Edvard Csanyi

Toyota Prius
Energy Efficiency

Electric Power Quality and Lighting (part 2)

Continued from first part: Electric Power Quality and Lighting (part 1) Power factor is a measure of how effectively a device converts input current and voltage into useful electric power…. Read more

May 29, 2012 | By Sufi Shah Hamid Jalali

Electric Power Quality and Lighting
Energy Efficiency

Electric Power Quality and Lighting (part 1)

Concerns about the effects of lighting products on power distribution systems have focused attention on power quality. Poor power quality can waste energy and the capacity of an electrical system;… Read more

May 26, 2012 | By Sufi Shah Hamid Jalali

Electric Power Quality and Lighting
Energy and Power

Process Design Basics for Station Facility

The purpose of this article is to establish the design basis electrical system Front End Engineering Design (FEED) and data design or standards uses in the gathering stations facility will… Read more

May 25, 2012 | By ivan.kurniawan

Process flow diagram
Power Substation

Transformer Connection Star-Star

The windings of three phase transformers may be connected in by Y or Δ in the same manner as for three single phase transformer. Since the secondary’s may be connected either… Read more

May 23, 2012 | By jiguparmar

Dry type cast resin transformer
Energy and Power

Special considerations when selecting transformer protection

Current transformer ratio selection and performance require special attention when applying transformer protection. Unique factors associated with transformers, including its winding ratios, magnetizing inrush current, and the presence of winding… Read more

May 19, 2012 | By Edvard Csanyi

Dry-type power transformers 11/0.42kV 2000kVA


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge