Technical Articles

How to save electrical energy at home

In our home we use lot of electrical equipment like TV, Freeze, Washing machine, Mp3 player, music system, computer laptop. But we have not adequate knowledge for how to use this electrical equipment in proper way. Due to this ignorance we are paying more electricity bill which we are not actually use. According to the …

Read More

Capacitor protection by surge arresters – ABB

Generally speaking, capacitor protection by surge arresters has been a difficult task before ZnO arresters became available. The high discharge currents and possible energies associated with an arrester operation at a capacitor bank heavily stressed the spark gaps in a SiC gapped arrester. The possible high energies could also result in overstressed SiC blocks. Once …

Read More

Autotransformers in few words

It is possible to obtain transformer action by means of a single coil, provided that there is a “tap connection” somewhere along the winding. Transformers having only one winding are called autotransformers, shown schematically in figure 1. An autotransformer has the usual magnetic core but only one winding, which is common to both the primary …

Read More

How Stuxnet (PLC virus) spreads – Part 4

Continued from How Stuxnet (PLC virus) spreads – Part 3 » Read here Propagation to other Perimeter Network Computers Once the worm has a foothold in the Perimeter Network, it would attempt to infect any print servers and file servers it could discover. Next, the worm would identify the WinCC software installed on the Web …

Read More

Budgeting and Financing Substation

The construction of new substations and the expansion of existing facilities are commonplace projects in electric utilities. However, due to the complexity, very few utility employees are familiar with the complete process that allows these projects to be successfully completed. This article will attempt to highlight the major issues associated with these capital-intensive construction projects, …

Read More

Applications and forms of differential relays

Differential relays take a variety of forms, depending on the equipment they protect. The definition of such a relay is “one that operates when the vector difference of two or more similar electrical quantities exceeds a predetermined amount. It will be seen later that almost any type of relay, when connected in a certain way, …

Read More

New download – Geothermal Electricity Basics

Geothermal electricity is electricity generated from geothermal energy. Technologies in use include dry steam power plants, flash steam power plants and binary cycle power plants. Geothermal electricity generation is currently used in 24 countries while geothermal heating is in use in 70 countries. Estimates of the electricity generating potential of geothermal energy vary from 35 …

Read More

Whole-House Protection Strategy

No single SPD (Surge Protection Strategy) can protect all the equipment in a residence from all causes of electrical surges. Instead, a whole-house protection strategy, consisting of point-of-entry and point-of-use SPDs, is necessary to help guard against disturbances from inside and outside the home. A point-of-entry SPD is necessary to limit damage from electrical surges …

Read More

Resistors in detail

Resistors are one of the simplest varieties of electronic components. A resistor is a two-terminal device that has a fixed relationship between the current passing through the device and the voltage drop across the device. This relationship is described in Ohm’s law, which states that “the strength of a direct current is directly proportional to …

Read More

Arrangement of hydropower plants

Hydropower machine is the designation used for a machine that directly convert the hydraulic power in a water fall to mechanical power on the machine shaft. This power conversion involves losses that arise partly in the machine itself and partly in the water conduits to and from the machine. The discharge operating a water turbine, …

Read More




Subscribe to free EEP’s updates

Subscribe to Monthly Download Updates:

(free electrical software, engineering guides and books)

Subscribe also to EE Technical Articles

Engineering Trainings

Top EEP’s Technical Writers

Technical Categories

Recommended to read and FREE download:
How heat pump works?

The heat pump transfers the heat between the heating/cooling distribution system and the earth connection. It is the basic building...

Risk and Consequences Of Transformer Fire

The risk of a catastrophic fire with a properly inspected, tested, and maintained transformer is small. Proper maintenance and thorough...

Line Protection With Distance Relays

Introduction Distance relaying should be considered when overcurrent relaying is too slow or is not selective. Distance relays are generally...