How to create a specific neutral earthing system within existing one (islanding)
Each neutral earthing system has advantages and disadvantages for the safety of property, electromagnetic compatibility or continuity of service. The main system must therefore be chosen according to these criteria,… Read more
Jul 18, 2018 | By Edvard Csanyi
Concerns over electromagnetic fields below three-phase high voltage overhead lines
In relation with the increased use of mobile phones during the last decades more concerns about possible harmful effects of electro-magnetic fields to human beings have been expressed. Overhead lines… Read more
Jul 16, 2018 | By Edvard Csanyi
Reasons and duties for switching in power transmission and distribution systems
The purpose of a power system is to transport and distribute the electric energy generated in the power plants to the consumers in a safe and reliable way. Generators take…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Log In »Purchase »
Jul 12, 2018 | By Edvard Csanyi
Eight substation equipment needed to power up data center
A few years ago I participated in an interesting project Telenor Data Center in Belgrade – The most advanced technical building in the region of Central and Eastern Europe. The… Read more
Jul 11, 2018 | By Edvard Csanyi
Why to automate power substation? What do you get?
Substation automation involves the deployment of substation and feeder operating functions and applications ranging from SCADA and alarm processing, to integrated volt-var control in order to optimize the management of… Read more
Jul 09, 2018 | By Edvard Csanyi
Using full potential of IEC 61850 with these 2 functions for digital substation automation
Since IEC 61850 was published as an international standard for communication in substations, the standard has found broad acceptance on the markets. In the first substations to use it, the… Read more
Jul 04, 2018 | By Edvard Csanyi
Selection of relay for incoming and outgoing feeders for MV and LV MCC switchgear
Selection of proper relay is one of the most important stages to have a reliable network. In this article, selection of relay for incoming and outgoing feeders for LV switchgear… Read more
Jul 02, 2018 | By Edvard Csanyi
What is the digital substation and what makes it digital?
The Digital Substation is a term applied to electrical substations where operation is managed between distributed intelligent electronic devices (IEDs) interconnected by communications networks. It became possible by using computing… Read more
Jun 27, 2018 | By Edvard Csanyi
How Arc suppression reactors (Earth fault neutralisers or Petersen-coils) work?
Arc-suppression reactors are also named earth fault neutralisers or Petersen-coils after W. Petersen who launched the idea of this particular reactor application early in the previous century. In high voltage… Read more
Jun 25, 2018 | By Edvard Csanyi
Measurements of bad impulsive noise in HV substation caused by partial discharge (PD) sources
The phenomenon of impulsive noise is generated by partial discharge (PD) sources in high voltage substations. A PD generates a current impulse, acoustic noise, visible and ultraviolet (UV) light and…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Log In »Purchase »
Jun 22, 2018 | By Edvard Csanyi
Current and voltage transformers (CTs and VTs) as protection’s eyes and ears
The CTs (current transformers) and VTs (voltage transformers) are provided in the plants to reduce the voltage and current values of the plant to values such as to be able… Read more
Jun 20, 2018 | By Edvard Csanyi
16 power correction devices available to install and really improve the power quality
All modern electronic devices are vulnerable to the poor power quality. But why? What can you do about it? This technical article describes 12 types of power correction devices (16… Read more
Jun 18, 2018 | By Edvard Csanyi
Four ways to bolster the short-circuit withstand capability of HV transformers
There are many methods applied to bolster the short circuit withstand capability of the transformers: improvement of the materials, reforming of the design and good maintenance in the operation process… Read more
Jun 13, 2018 | By Edvard Csanyi
MV/LV Power Substations Design and Schematics Notes (Network Supply and Enclosure Types)
Early consultation with the local Electricity Distributor is essential for agreement on a mutually approved MV/LV substation to act as the intake point for a particular site. This consultation is… Read more
Jun 11, 2018 | By Edvard Csanyi
Critical role of time synchronisation in IEC 61850 based digital protection systems
The needs and exact precision of time synchronization in IEC 61850 based digital protection systems have evolved. With new technologies and better distribution methods, most modern intelligent electronic devices (IEDs)…...
Premium Membership Required
This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Log In »Purchase »
Jun 08, 2018 | By Edvard Csanyi