Home / Technical Articles / Wind Power / What Is The Purpose Of Wind Farm Lighting?
What Is The Purpose Of Wind Farm Lighting?
What Is The Purpose Of Wind Farm Lighting?

Aircraft Warning Lights

Wind farm lighting includes:

  1. Aircraft warning lights that are installed on tops of some turbine nacelles and
  2. Night lights around wind farm buildings, parking lots, or other facilities.

Aircraft warning lights on top of tall telecommunications towers are known to be highly problematic for night-flying migratory birds (though not bats) during cloudy weather when the birds cannot navigate via the stars and are aĴracted to the lights, thereby colliding with the towers, guy wires, or each other.

Recent U.S. research indicates that white strobe lights with brief pulses are more bird friendly than solid or slowly pulsating red or white lights, since they seem to be less of an attractant to migrating birds on cloudy nights.

The windy sites most favorable for wind farm development often, though not always, have clear skies at night when night-flying birds are not attracted to artificial lights.

To minimize the risks that night-flying migrant birds will be attracted to wind turbines during overcast weather, aircraft warning lights would ideally be:

  1. White strobe lights and
  2. Placed a top a limited number of turbines to help show the wind farm outline, rather than on every one, consistent with national and local regulatory requirements.

In many low-risk cases far away from airports, such lights might not be needed at all; for example, U.S. law requires aircraft warning lights only on structures 200 feet or higher.

If aviation regulations provide flexibility regarding the type of aircraft warning lights to be used, it would also be important to consult with local residents regarding their aesthetic preferences, while also explaining the bird-friendly advantages of white strobe lights.

At the Mexico La Venta II project, only a small number of the 98 turbines have aircraft warning lights, which appears to be adequate for showing any pilots that might be in the area that there are multiple structures around, without potentially at-tracting numerous migrating birds to the turbines on overcast nights.

Night lighting close to ground level can also be managed to minimize bird and bat mortality.

Night lights around worker compounds, parking lots, and other wind farm facilities can attract to the wind farm migratory birds during cloudy weather, as well as bats and nocturnal birds (owls and nighjars) that seek out the flying insects that con-centrate around night lights.

In this regard, wind farm night lighting can be managed to minimize risks to birds and bats in ways that do not compromise worker safety and operational security.

These approaches include the use of:

  1. Sensors and switches to keep lights off when not needed and
  2. Lighting fixtures that are hooded and directed downward to minimize the skyward and horizontal illumination that could attract night-flying birds and bats to the vicinity of wind turbines.
Wind turbine lighting signalization
Wind turbine lighting signalization (on photo: SIEMENS wind turbine)

Resource: Greening the Wind | Environmental and Social Considerations for Wind Power Development – George C. Ledec, Kennan W. Rapp and Roberto G. Aiello

SEARCH: Articles, software & guides

Premium Membership

Premium membership gives you an access to specialized technical articles and extra premium content (electrical guides and software).
Get Premium Now ⚡

About Author


Edvard Csanyi

Electrical engineer, programmer and founder of EEP. Highly specialized for design of LV/MV switchgears and LV high power busbar trunking (<6300A) in power substations, commercial buildings and industry fascilities. Professional in AutoCAD programming. Present on


  1. Mike Pasqualetti
    Apr 08, 2017

    Do you know where you got the photo of the wind turbines at night? I would like to use it in a academic presentation if I may. Thank you.

  2. kanchi
    Apr 21, 2014


  3. Luciano Vasconcelos Crispiniano
    Feb 05, 2014

    Boa noite Srs, gostaria de receber informações sobre Wind power applications!

    Att Luciano

Leave a Comment

Tell us what you're thinking... we care about your opinion!

Premium Membership

Get access to premium electrical guides, technical articles and much more!