Search

Premium Membership ♕

Limited Time Offer: Save 15% on PRO Plan with discount code: LRN15 and study specialized LV/MV/HV technical articles and studies.

Home / Technical Articles / Why we find wind energy delivery factor important?
Why we find Wind Energy Delivery Factor important?
Why we find Wind Energy Delivery Factor important? (photo by Bill Doyle via Flickr)

Economic Performance Measure

The key economic performance measure of a power plant is the electrical energy it delivers over the year. Not all power produced is delivered to the paying customers. A fraction of it is used internally to power the control equipment, meeting the power equipment losses and for the housekeeping functions such as lighting.

In a typical wind farm (or photovoltaic park as well), about 90 percent of the power produced is delivered to the customers, and the remaining is self-consumed for the plant operation.

The quantity of energy delivered depends on the peak power capacity of the site and how fully that capacity is utilized over every hour of the year.

The normalized measure of the power plant performance is the Energy Delivery Factor (EDF).

It is defined as the ratio of the electrical energy delivered to the customers to the energy that can be delivered by the plant if it could be operated at the fully installed capacity during all 8,760 hours of the year, that is as follows:

Average annual EDF


Since the load power varies over the time, the EDF takes the integral form:

EDF integral form

where:

Pm – Plant capacity (the maximum power the plant can deliver)

Po – Power delivered to the customers at any time t


The EDF is usually determined by bookkeeping the sum of the energy delivered over a continuous series of small discrete time intervals, that is as follows:

Average annual EDF

where:

Pavg – average power delivered over the small time interval ∆t.

The EDF is a figure of merit that measures how hard the plant is utilized to deliver the maximum possible energy.

Not only does it include the energy conversion efficiencies of various components, it also accounts for the reliability, maintainability, and availability of the overall plant over the entire year.

Wind Farm in Cedar Creek, Colorado, USA
Wind Farm in Cedar Creek, Colorado, USA (photo by BP Images via Flickr)

The EDF is useful in comparing the economic utilization of one site over the other, or the annual performance of a given site. Wind plants operate with the annual average EDF around 30 percent, with some plants reporting EDF as high as 40 percent.

This compares with 40 to 80 percent for the conventional plants. The base load plants operate at the higher end of the range.

The wind farm energy delivery factor varies with season and that must be taken into account.

Resource: Wind and solar power systems – M. K. Patel

Premium Membership

Get access to premium HV/MV/LV technical articles, electrical engineering guides, research studies and much more! It helps you to shape up your technical skills in your everyday life as an electrical engineer.
More Information
author-pic

Edvard Csanyi

Electrical engineer, programmer and founder of EEP. Highly specialized for design of LV/MV switchgears and LV high power busbar trunking (<6300A) in power substations, commercial buildings and industry facilities. Professional in AutoCAD programming.

2 Comments


  1. aletourneau
    Apr 15, 2013

    Edvard- I cannot seem to find a rendition of the article with the formulae. In all versions I can find the formulas are replaces with the EEP LOGO. can I get a download of the article with the formulae?
    Thanks
    Andy


    • Edvard
      Apr 15, 2013

      Hi Aletourneau,

      This is very strange. Try clearing cookies in your browser. Pics in this article as well as in all other technical articles are present.

      However, try visiting RSS archive of this article here: http://eepurl.com/x6iMD

Leave a Reply to Edvard

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

seventy  ⁄    =  seven

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).
EEP Academy Courses - A hand crafted cutting-edge electrical engineering knowledge