Technical Articles In April, 2012

Energy and Power

Time relays setting ranges explained in details

Time relays are used in control switching operations involving time delay. Most of these time relays have multiple time setting ranges and most of them are explained below. Time relays perform either on-delay or off-delay timing. An arrow is used… Read more

Apr 30, 2012 | By

Siemens SIRIUS 3RP25 timing relay with microprocessor, OFF delay without auxiliary voltage, fully cover the functionality of the predecessor types on ASIC basis
Electric Motor

Measurement of insulation resistance (IR) – Part 2

This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more

Apr 29, 2012 | By

Fluke insulation resistance tester up to 10kV
Cables

Measurement of insulation resistance (IR)

The measurement of insulation resistance is a common routine test performed on all types of electrical wires and cables. As a production test, this test is often used as a customer acceptance test, with minimum insulation resistance per unit length… Read more

Apr 28, 2012 | By

Megger MIT1020 10-kV insulation resistance testers are all designed specifically to assist the user with the testing and maintenance of high voltage equipment
Energy and Power

Overview Of Electrical Loads In Building

The electrical design professional should determine a building’s electrical load characteristics early in the preliminary design stage of the building to select the proper power distribution system and equipment having adequate power capacity with proper voltage levels, and sufficient space… Read more

Apr 27, 2012 | By

Low voltage switchgear type 'OKKEN' - Schneider Electric
Lighting

Light Emission Depreciation

Illuminance provided initially by a lighting installation will decrease in a gradual way during its use due to a reduction in lamp lumens, to lamps which burn down, and to accumulation of dirtiness in lamps, luminaires and surfaces of the… Read more

Apr 24, 2012 | By

Dirty surface of the fluoroscent lamp
Electric Motor

Direct On Line (DOL) Motor Starter

Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting. We use a variety of starters in order to protect the windings from being damaged by the high current flow that is… Read more

Apr 22, 2012 | By

Direct On Line (DOL) Motor Starter
Transformers

What is the best transformer coolant?

One of the main sources of losses and reasons for temperature rise in various parts of a transformer are the magnetic circuit and windings. So what are the actually reasons of heating the transformer? Responsible for heat generation within the… Read more

Apr 20, 2012 | By

What is the best transformer coolant?
Metering

Analog Data Acquisition with Transducers

Transducers measure power system parameters by sampling instrument transformer secondaries. They provide a scaled, low-energy signal that represents a power system quantity that the SA interface controller can easily accept. Transducers also isolate and buffer the SA interface controller from… Read more

Apr 19, 2012 | By

Current transducer
Electrical Lectures

Inspection Of Voltage Drop In Conductors

It is part of the inspection process to ensure that installed conductors have been correctly selected for current carrying capacity and voltage drop. To check the suitability of the current carrying capacity it is simply a matter of looking at… Read more

Apr 15, 2012 | By

Inspection Of Voltage Drop In Conductors
Electrical Lectures

What is incident energy caused by arc flash?

Incident energy is the energy per unit area received on a surface located a working distance away from the arc flash location. The working distance is the distance from where the worker to the flash location. This is basically an… Read more

Apr 13, 2012 | By

Arc flash in switchboard
Energy and Power

Key Cyber Security Purposes for the Smart Grid

In the Smart Grid, there are two key purposes for cyber security: Keep electricity flowing to customers, businesses, and industry. For decades, the power system industry has been developing extensive and sophisticated systems and equipment to avoid or shorten power… Read more

Apr 12, 2012 | By

Key Cyber Security Purposes for the Smart Grid
Electric Motor

Star-delta motor starter explained in details

Where is Star-Delta motor starter used? Well, the majority of induction motors are started directly on line (DOL), but when very big motors are started in this manner, the large starting current surges produce a disruption in the voltage on… Read more

Apr 10, 2012 | By

Star-delta motor starter explained in details
Electrical Lectures

Short review of resistance, reactance and impedance

Resistance is essentially friction against the motion of electrons. It is present in all conductors to some extent (except superconductors!), most notably in resistors. When alternating current goes through a resistance, a voltage drop is produced that is in-phase with… Read more

Apr 08, 2012 | By

Figure 1 - Perfect resistor, inductor and capacitor