Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Technical Articles In May, 2012

Smart Grid

Electric Vehicles and the Smart Grid

Another source of urgency for the smart grid is meeting goals for getting more “clean” cars and vehicles on the road. Electric vehicles largely eliminate greenhouse gas emissions from vehicle tail pipes. As part of the stimulus package, President Obama… Read more

May 30, 2012 | By

Toyota Prius
Energy and Power

Process Design Basics for Station Facility

The purpose of this article is to establish the design basis electrical system Front End Engineering Design (FEED) and data design or standards uses in the gathering stations facility will be built. Electrical system design refers to the process flow diagram… Read more

May 25, 2012 | By

Process flow diagram
Power Substation

Transformer Connection Star-Star

The windings of three phase transformers may be connected in by Y or Δ in the same manner as for three single phase transformer. Since the secondary’s may be connected either in Y or Δ regardless of which connection is used on… Read more

May 23, 2012 | By

Dry type cast resin transformer
Industrial Automation

Using MODBUS for Process Control and Automation (1)

MODBUS is the most popular industrial protocol being used today, for good reasons. It is simple, inexpensive, universal and easy to use. Even though MODBUS has been around since the past century nearly 30 years, almost all major industrial instrumentation… Read more

May 21, 2012 | By

The Schneider Electric PLC - Modicon Quantum
Energy and Power

Special considerations when selecting transformer protection

Current transformer ratio selection and performance require special attention when applying transformer protection. Unique factors associated with transformers, including its winding ratios, magnetizing inrush current, and the presence of winding taps or load tap changers, are sources of difficulties in… Read more

May 19, 2012 | By

Dry-type power transformers 11/0.42kV 2000kVA
Electrical Lectures

Power Measurement In AC Circuits

Power measurement in AC circuits can be quite a bit more complex than with DC circuits for the simple reason that phase shift complicates the matter beyond multiplying voltage by current figures obtained with meters. What is needed is an instrument… Read more

May 15, 2012 | By

GE Watthour Meter
Energy and Power

Introduction to instrument transformers

Instrument transformers (ITs) are designed to transform voltage of current from the high values in the transmission and distribution systems to the low values that can be utilized by low voltage metering devices. There are three primary applications for which… Read more

May 14, 2012 | By

Instrument transformers - ABB
Metering

An Overview Of Clamp Meter

Clamp-on ammeter or simply ‘clamp meter’ is an instrument that is used to measure the current flowing through a conductor. An AC Clamp meter basically consists of a current transformer in its jaws, bar CT usually. Utilizing the principle of… Read more

May 06, 2012 | By

Clapm meter


EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.