Electrical Lectures

Fundamental Characteristics of Circuit Breaker

The fundamental characteristics of a circuit breaker are: Its rated voltage Ue Its rated current In Its tripping current level adjustment ranges for overload protection (Ir or Irth) and for short circuit protection (Im) Current-level setting values which refer to the… Read more

Jun 05, 2012 | By

Fundamental characteristics of circuit breakers
Energy and Power

Understanding Vector Group of Transformer (Part 2)

Vector Groups are the IEC method of categorizing the primary and secondary winding configurations of 3-phase transformers. Windings can be connected as delta, star, or interconnected-star (zigzag). Winding polarity is also important, since reversing the connections across a set of… Read more

Jun 04, 2012 | By

220kV Class 110kV Class Single Phase Traction Transformer
Smart Grid

Electric Vehicles and the Smart Grid

Another source of urgency for the smart grid is meeting goals for getting more “clean” cars and vehicles on the road. Electric vehicles largely eliminate greenhouse gas emissions from vehicle tail pipes. As part of the stimulus package, President Obama… Read more

May 30, 2012 | By

Toyota Prius
Energy and Power

Process Design Basics for Station Facility

The purpose of this article is to establish the design basis electrical system Front End Engineering Design (FEED) and data design or standards uses in the gathering stations facility will be built. Electrical system design refers to the process flow diagram… Read more

May 25, 2012 | By

Process flow diagram
Power Substation

Transformer Connection Star-Star

The windings of three phase transformers may be connected in by Y or Δ in the same manner as for three single phase transformer. Since the secondary’s may be connected either in Y or Δ regardless of which connection is used on… Read more

May 23, 2012 | By

Dry type cast resin transformer
Industrial Automation

Using MODBUS for Process Control and Automation (1)

MODBUS is the most popular industrial protocol being used today, for good reasons. It is simple, inexpensive, universal and easy to use. Even though MODBUS has been around since the past century nearly 30 years, almost all major industrial instrumentation… Read more

May 21, 2012 | By

The Schneider Electric PLC - Modicon Quantum
Energy and Power

Special considerations when selecting transformer protection

Current transformer ratio selection and performance require special attention when applying transformer protection. Unique factors associated with transformers, including its winding ratios, magnetizing inrush current, and the presence of winding taps or load tap changers, are sources of difficulties in… Read more

May 19, 2012 | By

Dry-type power transformers 11/0.42kV 2000kVA
Electrical Lectures

Power Measurement In AC Circuits

Power measurement in AC circuits can be quite a bit more complex than with DC circuits for the simple reason that phase shift complicates the matter beyond multiplying voltage by current figures obtained with meters. What is needed is an instrument… Read more

May 15, 2012 | By

GE Watthour Meter
Energy and Power

Introduction to instrument transformers

Instrument transformers (ITs) are designed to transform voltage of current from the high values in the transmission and distribution systems to the low values that can be utilized by low voltage metering devices. There are three primary applications for which… Read more

May 14, 2012 | By

Instrument transformers - ABB


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.