Metering

An Overview Of Clamp Meter

Clamp-on ammeter or simply ‘clamp meter’ is an instrument that is used to measure the current flowing through a conductor. An AC Clamp meter basically consists of a current transformer in its jaws, bar CT usually. Utilizing the principle of… Read more

May 06, 2012 | By

Clapm meter
Energy and Power

Using AC and DC together in electrical system?

There are a number of issues to using AC and DC together in the same electrical system. Briefly, they are: circuit boxes and hardware, outlets, wiring schemes and sizes, and switches. The Electrical Code prohibits AC and DC in the same box. You’ll need two… Read more

May 05, 2012 | By

Using AC and DC together in electrical system?
Energy and Power

Types of Residual Current Devices (RCD)

For domestic applications only the first five of the below listed residual current devices (RCD) need to be considered. For industrial and commercial buildings all of the classifications need to be considered. Table below aims to identify where each type… Read more

May 03, 2012 | By

Residual current device 30mA - SIEMENS
Energy and Power

Time relays setting ranges explained in details

Time relays are used in control switching operations involving time delay. Most of these time relays have multiple time setting ranges and most of them are explained below. Time relays perform either on-delay or off-delay timing. An arrow is used… Read more

Apr 30, 2012 | By

Siemens SIRIUS 3RP25 timing relay with microprocessor, OFF delay without auxiliary voltage, fully cover the functionality of the predecessor types on ASIC basis
Electric Motor

Measurement of insulation resistance (IR) – Part 2

This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more

Apr 29, 2012 | By

Fluke insulation resistance tester up to 10kV
Cables

Measurement of insulation resistance (IR)

The measurement of insulation resistance is a common routine test performed on all types of electrical wires and cables. As a production test, this test is often used as a customer acceptance test, with minimum insulation resistance per unit length… Read more

Apr 28, 2012 | By

Megger MIT1020 10-kV insulation resistance testers are all designed specifically to assist the user with the testing and maintenance of high voltage equipment
Energy and Power

Overview Of Electrical Loads In Building

The electrical design professional should determine a building’s electrical load characteristics early in the preliminary design stage of the building to select the proper power distribution system and equipment having adequate power capacity with proper voltage levels, and sufficient space… Read more

Apr 27, 2012 | By

Low voltage switchgear type 'OKKEN' - Schneider Electric
Lighting

Light Emission Depreciation

Illuminance provided initially by a lighting installation will decrease in a gradual way during its use due to a reduction in lamp lumens, to lamps which burn down, and to accumulation of dirtiness in lamps, luminaires and surfaces of the… Read more

Apr 24, 2012 | By

Dirty surface of the fluoroscent lamp
Electric Motor

Direct On Line (DOL) Motor Starter

Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting. We use a variety of starters in order to protect the windings from being damaged by the high current flow that is… Read more

Apr 22, 2012 | By

Direct On Line (DOL) Motor Starter
Transformers

What is the best transformer coolant?

One of the main sources of losses and reasons for temperature rise in various parts of a transformer are the magnetic circuit and windings. So what are the actually reasons of heating the transformer? Responsible for heat generation within the… Read more

Apr 20, 2012 | By

What is the best transformer coolant?
Metering

Analog Data Acquisition with Transducers

Transducers measure power system parameters by sampling instrument transformer secondaries. They provide a scaled, low-energy signal that represents a power system quantity that the SA interface controller can easily accept. Transducers also isolate and buffer the SA interface controller from… Read more

Apr 19, 2012 | By

Current transducer


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.