Few more words about energy stored in batteries
Electrochemical storage systems In this article various types of batteries are described. Most of them are technologically mature for practical use. First, six secondary battery types are listed: lead acid, NiCd/NiMH, Li-ion, metal air, sodium sulphur and sodium nickel chloride;… Read more
Mar 19, 2012 | By Edvard Csanyi
Difference between step-up transformer and voltage amplifier
A step up transformer basically increases the magnitude of primary applied voltage that is increases the amplitude of voltage wave form. A voltage amplifier does exactly the same. Than a very strange but thinkable question comes what is the difference… Read more
Mar 17, 2012 | By Asif Eqbal
Copper or aluminium? Which one to use and when?
Apart from their electrical conductivity, the other technologically important properties of copper and aluminium differ so significantly (density is an obvious example) that their areas of application are and have always been clearly distinct. And not a lot has changed… Read more
Mar 16, 2012 | By Edvard Csanyi
Megger Insulation Resistance Test
As you know good insulation has high resistance and poor insulation relatively low resistance. The actual resistance values can be higher or lower, depending upon such factors as the temperature or moisture content of the insulation (resistance decreases in temperature… Read more
Mar 13, 2012 | By Edvard Csanyi
Different types of battery used for auxiliary power supply in substations and power plants
In industrial or substation applications mainly three types of batteries are used namely: Vented / Flooded Lead Acid batteries Sealed maintenance free batteries/Valve Regulated Lead Acid Nickel Cadmium (Ni-cd) batteries For UPS applications batteries are the most popular and hence… Read more
Mar 12, 2012 | By Asif Eqbal
Renewable Energy Outlook – Wind Power
With the exception of hydroelectric power, the wind-power industry is far more developed than most other types of renewable energy. Over the past decade, the technology associated with wind power has improved significantly. In addition, wind turbines that generate the… Read more
Mar 10, 2012 | By Edvard Csanyi
Sudden pressure relay in oil-filled power transformer
Internal arcing in an oil-filled power transformer can instantly vaporize surrounding oil, generating gas pressures that can cause catastrophic failure, rupture the tank, and spread flaming oil over a large area. This can damage or destroy other equipment in addition… Read more
Mar 08, 2012 | By Edvard Csanyi
The real truth behind household power savers
A household power low voltage saving devices has recently received a lot of attention from both consumers and manufacturers. It is generally used in residential homes to save energy and to reduce electricity bills. It is a small device which… Read more
Mar 07, 2012 | By Jignesh Parmar
Using HVDC Technology For Transmitting Electricity
An alternate means of transmitting electricity is to use high-voltage direct current (HVDC) technology. As the name implies, HVDC uses direct current to transmit power. Direct current facilities are connected to HVAC systems by means of rectifiers, which convert alternating… Read more
Mar 05, 2012 | By Edvard Csanyi
Coal handling plant in a thermal power generating station
In a coal based thermal power plant, the initial process in the power generation is “Coal Handling”. So in this article i will discuss the overall processes carried out at a Coal Handling plant in a coal based thermal power… Read more
Mar 04, 2012 | By Bipul Raman
Capacitor Banks In Power System (part three)
Continued from part two – Capacitor Banks In Power System (part two) Capacitor units shall be suitable for continuous operation at an RMS current of 1.30 times the current that occurs at rated sinusoidal voltage and rated frequency, excluding transients…. Read more
Mar 03, 2012 | By Asif Eqbal
Capacitor Banks In Power System (part two)
Continued from part one – Capacitor Banks In Power System (part one) It should be noted that in an inductance the current lags the voltage by 90 degrees and in a capacitor the current leads the voltage by 90 degrees…. Read more
Mar 01, 2012 | By Asif Eqbal
Why do we find electric motor drive very important?
Electric motors impact almost every aspect of modern living. Refrigerators, vacuum cleaners, air conditioners, fans, computer hard drives, automatic car windows, and multitudes of other appliances and devices all use electric motors to convert electrical energy into useful mechanical energy…. Read more
Feb 29, 2012 | By Edvard Csanyi
Capacitor banks in power system (part 1)
When a charge is delivered to a conductor its potential is raised in proportion to the quantity of charge given to it. At a particular potential a conductor can hold a given amount of charge. Capacitance is the term to… Read more
Feb 27, 2012 | By Asif Eqbal
How to explain your kids, what is the electricity?
It’s really not an easy task to explain kids what is the electricity and what is really happening in the wires while lamp is powered, or what are the magnets, magnetism and how all this stuff works. Most important of… Read more
Feb 26, 2012 | By Edvard Csanyi