How to Protect Capacitor Banks?
Capacitor banks are used to compensate for reactive energy absorbed by electrical system loads, and sometimes to make up filters to reduce harmonic voltage. Their role is to improve the quality of the electrical system. They may be connected in… Read more
Oct 05, 2012 | By Edvard Csanyi
Basic steps in PLC programming for beginners
The first step in developing a control program is the definition of the control task. The control task specifies what needs to be done and is defined by those who are involved in the operation of the machine or process…. Read more
Oct 04, 2012 | By Edvard Csanyi
Dry Transformer Percent Impedance Definition
The percent impedance is the percent voltage required to circulate rated current flow through one transformer winding when another winding is short-circuited at the rated voltage tap at rated frequency. %Z is related to the short circuit capacity of the transformer during short… Read more
Oct 03, 2012 | By Edvard Csanyi
Definitions of Abnormal Voltage Conditions
A sag is a temporary reduction in the normal AC voltage. A momentary sag is a variation, which lasts for a period of 0.5 cycle to about 2 s usually the result of a short circuit somewhere in the power system. Instances… Read more
Oct 02, 2012 | By Edvard Csanyi
Designing of HV Power Substation and Layout
Introduction Earthing and Bonding Substation Earthing Calculation Methodology (Earthing Materials) Layout of Substation Different Layouts for Substations (single busbar, mesh, 1 1/2 cb) Principle of Substation Layouts (spatial separation, maintenance zones) Components of a Substation (cbs, cts, isolators, insulation, transformers etc.) Substations are the… Read more
Oct 01, 2012 | By sprabakar22
Right Choice of Dry Type or Liquid-Filled Transformer
1. Two Types of Transformers 2. Cooling and insulating system 3. Losses 4. Operating Life of Transformer 5. Maintainability 6. Repairability 7. Core/Coil Reclamation and Recycling 8. Operating Sound Level and Noise Pollution 9. Footprint 0. Conclusion Information on the… Read more
Sep 29, 2012 | By Edvard Csanyi
Overview of Single Phase Induction Type Energy Meter
Single phase induction type energy meter is also popularly known as watt-hour meter. This name is given to it. This article is only focused about its constructional features and its working. Induction type energy meter essentially consists of following components:… Read more
Sep 28, 2012 | By Bipul Raman
What is the difference between Bonding, Grounding and Earthing?
One of the most misunderstood and confused concept is difference between Bonding, Grounding and Earthing. Bonding is more clear word compare to Grounding and Earthing, but there is a micro difference between Grounding and Earthing. Earthing and Grounding are actually… Read more
Sep 27, 2012 | By Jignesh Parmar
How Sensitive Circuits Are Affected By Noise And What Can You Do About It?
Noise is only important if it is measured in relation to the communication signal, which carries the data or information. Electronic receiving circuits for digital communications have a broad voltage range, which determines whether a signal is binary bit ‘1’… Read more
Sep 26, 2012 | By Edvard Csanyi
Inspection of Ground-Fault Protection Systems
This type of protection is defined by the NEC (National Electrical Code) to ensure protection against fire on electrical power installations. To ensure protection against fire: The NEC defines the use of an RCD with very low sensitivity called GFP IEC… Read more
Sep 25, 2012 | By Edvard Csanyi
Testing and Commissioning of Metal-Clad Switchgear
Electrical testing and commissioning of Metal-Clad switchgear is essential to the safe start for the first time, regardless of its size, type or industry. This article covers testing and start-up / commisioning procedures for all the components of medium voltage… Read more
Sep 24, 2012 | By Edvard Csanyi
Surge Protection of Electronic Equipment
Generally, power circuits have components that have large thermal capacities, which make it impossible for them to attain very high temperatures quickly except during very large or long disturbances. This requires correspondingly large surge energies. Also, the materials that constitute… Read more
Sep 22, 2012 | By Edvard Csanyi
Introduction to Static Protection Relays
The term ‘static’ implies that the relay has no moving parts. This is not strictly the case for a static relay, as the output contacts are still generally attracted armature relays. In a protection relay, the term ‘static’ refers to… Read more
Sep 21, 2012 | By Edvard Csanyi
What is the purpose of equipotential bonding?
Equipotential bonding is essentially an electrical connection maintaining various exposed conductive parts and extraneous conductive parts at substantially the same potential. An earthed equipotential zone is one within which exposed conductive parts and extraneous conductive parts are maintained at substantially… Read more
Sep 20, 2012 | By Edvard Csanyi
Design of Overhead Transmission Line Foundation
The foundation is the name given to the system which transfers to the ground the various steady state (dead) and variable (live) loads developed by the transmission tower and conductors. Foundations may be variously subjected to compressive or bearing forces,… Read more
Sep 19, 2012 | By Edvard Csanyi