Differences between Shunt Reactor and Power Transformer
Shunt Reactor and Transformer both appear similar in construction. Reactors are also often equipped with Fans for cooling similar to Power Transformers. However, there are major differences between the two. While a Power Transformer is designed for efficient power transfer… Read more
Sep 18, 2012 | By Edvard Csanyi
Definition of Harmonics and Their Origin
The Fourier theorem states that all non-sinusoidal periodic functions can be represented as the sum of terms (i.e. a series) made up of: A sinusoidal term at the fundamental frequency, Definition of Harmonics and Their Origin Sinusoidal terms (harmonics) whose… Read more
Sep 17, 2012 | By Edvard Csanyi
Qatar General Electricity and Water Corporation – Recommendations for Safety Clearance
Service Vertical Clearance (Min) Water Line (to cross below EHV cable level) 0.5 Meter Sewerage Mains (to cross below EHV cable level) 1.0 Meter Drainage Mains (to cross below EHV cable level) 0.5 Meter Gas pipes 0.6 Meter Telephone lines… Read more
Sep 15, 2012 | By Jignesh Parmar
Functions Performed by Electrical Switchgear
National and international standards define the method for making electrical distribution circuits as well as the purpose and functions of switchgear. There are three main functions, namely: Circuit protection takes three main fault types into account: Overloads, Short-circuits (Both of which… Read more
Sep 14, 2012 | By Edvard Csanyi
Analog signals in measurement and control of physical processes
Instrumentation is a field of study and work centering on measurement and control of physical processes. These physical processes include pressure, temperature, flow rate, and chemical consistency. An instrument is a device that measures and/or acts to control any kind… Read more
Sep 13, 2012 | By Edvard Csanyi
Nikola Tesla – Everything is the Light
Once, in 1899, Nikola Tesla had an interview with certain journalist John Smith, when Tesla said “Everything is the Light“. In one of its rays is the fate of nations, each nation has its own ray in that great light source,… Read more
Sep 12, 2012 | By Edvard Csanyi
LT / Medium / HT VFD Used In the Industry (part 2)
Consider the application of a drive to a cane milling unit where the speed is to be variable from full to half rated speed. The drive is to be capable of producing full rated torque over the entire speed range…. Read more
Sep 11, 2012 | By sprabakar22
LT / Medium / HT VFD Used In the Industry (1)
In modern plants, there are number of drives like Milling Plant Drive, Hydraulic Drive, DC Motor Drive and AC Motor Drive of adequate capacities are available. There is lot of scope for improving the overall efficiency and saving the energy… Read more
Sep 10, 2012 | By sprabakar22
Under the Hood of LEDs (Light Emitting Diodes)
LED lamps, or Light Emitting Diodes, are becoming more and more common. Having been used for some time in products such as digital watches, remote controls and brake lights, they are now being seen in many more applications such as… Read more
Sep 08, 2012 | By Paul Blythe
Things You Should Know Before Planning of Hydroelectric Facilities
Hydroelectric plants are located in geographic areas where they will make economic use of hydraulic energy sources. Hydraulic energy is available wherever there is a flow of liquid and head. Head represents potential energy and is the vertical distance through… Read more
Sep 07, 2012 | By Edvard Csanyi
Transformer Heat, Copper and Iron Losses
The thermal ratings of a transformer are determined by the following three factors: The amount of heat produced in the windings and connections. The amount of heat produced in the iron core. How effectively the heat can be removed from… Read more
Sep 06, 2012 | By Edvard Csanyi
Transformer differential protection (ANSI 87T)
Transformer differential protection protects against short-circuits between turns of a winding and between windings that correspond to phase-to-phase or three-phase type short-circuits. If there is no earthing connection at the transformer location point, this protection can also be used to… Read more
Sep 05, 2012 | By Edvard Csanyi
How to Maximize Chiller Efficiency?
Chillers are the single largest energy-using component in most facilities, and can typically consume over 50% of the electrical usage. Chillers use approximately 20% of the total electrical power generated in North America and the U.S. Department of Energy estimates… Read more
Sep 04, 2012 | By Edvard Csanyi
Getting Electricity From Solid Oxide Fuel Cell
Abstract Introduction Fuel Cell Working Principle of SOFC Materials Selection and Processing Cathode Electrolyte Anode Interconnection Types of SOFC Merits and Demerits Applications Stationary energy sources Transportation Military applications SOFC-GT Conclusions Electricity is no more a luxury but it has… Read more
Sep 03, 2012 | By vinod ramireddy
Transformers Connected Directly to Generators
Power transformers connected directly to generators can experience excitation and short-circuit conditions beyond the requirements defined by ANSI/IEEE standards. Special design considerations may be necessary to ensure that a power transformer is capable of withstanding the abnormal thermal and mechanical aspects that… Read more
Sep 01, 2012 | By Edvard Csanyi