Technical Articles In January, 2013

Transformers

What is transformer rating based on?

In the U.S., transformers are rated based on the power output they are capable of delivering continuously at a specified rated voltage and frequency under “usual” operating conditions without exceeding prescribed internal temperature limitations. Insulation is known to deteriorate with… Read more

Jan 30, 2013 | By

What is transformer rating based on?
High Voltage

High Voltage Substations Overview (part 2)

Continued from first part: High Voltage Substations Overview (part 1) Transformers are used for the transformation of high and medium voltage to low voltage, flanked by specific protective devices and control systems, which constitute the low voltage distribution substations. A… Read more

Jan 26, 2013 | By

High Voltage Substations Overview (part 2)
High Voltage

High voltage substations overview (part 1)

High voltage substations are interconnection points within the power transmission and distribution systems between regions and countries. Different applications of substations lead to HV substations with and without power transformers: Step up from a generator voltage level to a high voltage… Read more

Jan 25, 2013 | By

Substations and Distribution Substations Overview
Energy and Power

Comparison of Protection Relay Types

This comparison summarize characteristics of all protection relay types described in previously published technical articles: Using Protective Relay For Fighting Against Faults The Good Old Electromechanical Protective Relay The Solid State Relay (Static Relay) Overview Few Words About Digital Protection… Read more

Jan 23, 2013 | By

Comparison of Protection Relay Types
Energy and Power

Power measurement in a three-phase system

Electrical power is measured with a wattmeter. A wattmeter consists of a current coil connected in series with load, while the other potential coil is connected parallel with load. Depending on the strength of each magnetic field movement, the pointer… Read more

Jan 19, 2013 | By

Power Measurement In a Three-Phase System
Cables

Underground residential distribution layouts

Where general appearance, economics, congestion, or maintenance conditions make overhead construction inadvisable, underground construction is specified. While overhead lines have been ordinarily considered to be less expensive and easier to maintain, developments in underground cables and construction practices have narrowed… Read more

Jan 18, 2013 | By

Underground residential distribution layouts
Transformers

D.M.C.R. Protection Relay for Oil Transformer

Introduction to D.M.C.R. Faults detected on live transformer unit: Dielectric fluid level is detected as low Overheating is detected Excess pressure is detected Standards Possibilities of D.M.C.R.: Oil level control and gas detection Pressure control Temperature control The DMCR is… Read more

Jan 16, 2013 | By

DMCR - Detection, Measurement and Control Relay for Hermetically Sealed Oil Transformer
High Voltage

Purpose of Disconnect Switches In HV Substation

Switches may be of several types, the common characteristic is that none are designed to interrupt fault currents and the insulation or insulators associated with them must coordinate with the rest of the system and a BIL (Basic insulation level)… Read more

Jan 14, 2013 | By

Purpose of Disconnect Switches In HV Substation (on photo: Siemens Goab switch)
Cables

Testing and Commissioning of MV/HV Cables

Compare cable data with drawings and specifications. Inspect exposed sections of cables for physical damage. Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter in accordance with Section 1.2 above…. Read more

Jan 12, 2013 | By

Testing and Commissioning of MV/HV Cables
Testing and Commissioning

Testing and Commissioning of Substation DC System

Power substation DC system consists of battery charger and battery. This is to verify the condition of battery and battery charger and commissioning of them. Following instruments will be used for testing: Multimeter. (Learn how to use it) Battery loading… Read more

Jan 09, 2013 | By

Testing and Commissioning of Substation DC System
High Voltage

Environmental Stresses On External Insulation

The external insulation (transmission line or substation) is exposed to electrical, mechanical, and environmental stresses. The applied voltage of an operating power system produces electrical stresses. The weather and the surroundings (industry, rural dust, oceans, etc.) produce additional environmental stresses…. Read more

Jan 07, 2013 | By

Environmental Stresses On External Insulation