Technical Articles In May, 2013

Energy and Power

MCset – Air Insulated Switchgear with SF6 CB

MCset is Schneider Electric‘s AIS – Air Insulated Switchgear (indoor metal-enclosed device) intended for the MV section of HV/MV substations and high power MV/MV substations up to 24kV. Main component of MCset is circuit breaker which is SF6 type. MCset – Air… Read more

May 31, 2013 | By

MCset Air Insulated Switchgear with SF6 CB (up to 24kV)
Electric Motor

Three Phenomenons In The Iron Of AC Machines

Most of our practical AC machines (motors, generators ad transformers) depend heavily on the magnetic field for operation. The core iron of the machine provides a path for the magnet field. There are a number of phenomena in the iron… Read more

May 29, 2013 | By

Three phenomenons in the iron of AC machines
Testing and Commissioning

Condition Monitoring of Transformers

It is possible to provide transformers with measuring devices to detect early signs of degradation in various components and provide warning to the operator in order to avoid a lengthy and expensive outage due to failure. The technique, which can… Read more

May 24, 2013 | By

Condition Monitoring of Transformers (on photo: distributive tranformer
Testing and Commissioning

Transformer Routine Dielectric (Insulation) Test

The following insulation tests are performed in order to meet the transformer insulation strength expectations. Unless otherwise requested by the customer, the following test are performed in the following order (IEC 60076-3) : To confirm the insulation of the transformer terminals… Read more

May 23, 2013 | By

Transformer Routine Dielectric (Insulation) Test
Testing and Commissioning

Erection Procedure for Power Transformer

This technical article deals with transformers and their installation so we restrict ourselves here to the procedures associated with their commissioning. Transformers should be inspected for internal or external damage, particularly if they have been dropped or tipped over. This should include such… Read more

May 20, 2013 | By

Erection Procedure for Power Transformer
Industrial Automation

Requirements and Functions of Substation Automation

Substation automation is the cutting edge technology in electrical engineering. It means having an intelligent, interactive power distribution network including : Increased performance and reliability of electrical protection. Advanced disturbance and event recording capabilities, aiding in detailed electrical fault analysis…. Read more

May 17, 2013 | By

Requirements and Functions of Substation Automation
Energy and Power

Switching contactor and effect of long control lines

In accordance with IEC 60947-4-1 and IEC 60947-5-1, the normal control voltage range of power and control contactors lies between 85 … 110 % of the rated control voltage. Within these limits contactors pull-in perfectly. Frequently contactors are offered with… Read more

May 15, 2013 | By

Switching contactor and effect of long control lines
Energy and Power

Ferroresonance Occurrence In Power Transformer

Ferroresonance occurs when line capacitance resonates with the magnetizing reactance of a core while it goes in and out of saturation. Ferroresonance is usually associated with potential transformers, which are instrument transformers that are used to develop voltages used by… Read more

May 10, 2013 | By

Ferroresonance Occurrence In Power Transformer
Testing and Commissioning

When a transformer has stomach pain and wants to…

During normal operation, transformer internal structures and windings are subjected to mechanical forces due to the magnetic forces. These forces are illustrated in Figure 1. By designing the internal structure very strong to withstand these forces over a long period of… Read more

May 08, 2013 | By

Transformer windings forces due to the magnetic forces