Testing Procedures for HV Voltage Transformers
Equipment required for testing General inspection Insulation Resistance Test Polarity Test Transformer Turns ratio test Following equipment is necessary to perform testings: Polarity test kit Megger 500-5000V Ohmmeter Multimeter Autotransformers & Step-up transformers Go up to the Content General visual… Read more
Feb 28, 2014 | By Edvard Csanyi
Practices for grounding and bonding of cable trays
Cable tray may be used as the Equipment Grounding Conductor (EGC) in any installation where qualified persons will service the installed cable tray system. There is no restriction as to where the cable tray system is installed. The metal in… Read more
Feb 26, 2014 | By Edvard Csanyi
Inspection and test procedures for Rotating Machinery, Synchronous Motors and Generators
Visual and Mechanical Inspection Electrical Tests Test Values Visual and Mechanical Tests Electrical Tests Pictures: Electrical machine wired for electrical testing The Electrical Machines Laboratory TABLE 100.10 – Maximum Allowable Vibration Amplitude TABLE 100.12 – US Standard Fasteners Compare equipment… Read more
Feb 19, 2014 | By Edvard Csanyi
How challenging can be transporting of a Large Power Transformer (LPT)
Transporting an Large power transformer (LPT) can be quite challenging. LPTs large dimensions and heavy weight pose unique requirements to ensure safe and efficient transportation. Current road, rail, and port conditions are such that transportation is taking more time and… Read more
Feb 14, 2014 | By Edvard Csanyi
Effect of utility-induced surges in a steel mill with variable speed drives
A steel mill with variable speed drives (VSDs) had problems of frequent tripping of the VSDs with the indication overvoltage in AC line. Each tripping caused severe production disruption and resulted in considerable monetary loss due to lost production. Steady-state… Read more
Feb 12, 2014 | By Edvard Csanyi
What is the short-circuit switching (making / breaking) capacity?
The switching capacity is the r.m.s value of a current at a given power factor cos φ as well as a given rated voltage at which a switchgear or a fuse can still shut-off under specified conditions in an operationally… Read more
Feb 10, 2014 | By Edvard Csanyi
Electrical Preventive Maintenance of Air Circuit Breakers
Remove and clean interphase barriers. Clean all insulating materials with vacuum and/or clean lint free rags. If it is necessary to use cleaning solvents, use only solvents recommended by the manufacturer. Inspect for (early) signs of corona, tracking, arcing, or… Read more
Feb 07, 2014 | By Edvard Csanyi
Purposes and Examples of Safety Interlocking Devices
Most switchboards and motor control centres are fitted with a variety of electrical and mechanical safety interlocking devices. Their purposes are to protect against for example: Withdrawing the switching device while it is carrying load or fault current. Prevent the switching… Read more
Feb 05, 2014 | By Edvard Csanyi
Conceptual Model of Smart Grid Framework by IEC
From a communication point of view, each system plays the role of either supplier or consumer of information, or more typically both. In addition to this intersystem communication, these systems consist of subsystems with specific internal communications. The following paragraphs… Read more
Feb 03, 2014 | By Edvard Csanyi