Installation guidelines for MV metal-enclosed switchgear and controlgear (IEC 62271-200)
What does it mean ‘metal-enclosed switchgear’? Metal-enclosed switchgear and controlgear are generally assembled from type-tested panels. As per IEC 62271-200 metal-enclosed switchgear installations must be designed so that their insulation capacity, degree of protection, current carrying capacity, switching capacity and… Read more
Jul 27, 2020 | By Edvard Csanyi
How system earthing keeps you and the network safe
The term “earthing” consists of several functions which only have “utilizing the earth” in common. Before describing the system earthing, it can be of interest to know a bit about the different types of earthing. Protective earthing is applicable mainly… Read more
Jul 22, 2020 | By Edvard Csanyi
A case study of fault level calculations for a MV/LV network using direct method
This technical article represents the case study of fault level calculations for an MV/LV network using the direct method. There are many advantages of the direct approach, and the main of them is that it directly uses the system single…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Jul 19, 2020 | By Sivakumar K
Control system equipment that supervises, protects and controls the substation operation
The control system equipment in a substation is a vital part that supervises, protects and controls the transmission of electrical power. The increasing complexity in the substations of today, together with the increasing transmitted power and the increasing fault current… Read more
Jul 13, 2020 | By Edvard Csanyi
Protection coordination practices in distribution systems with distributed generation
Generally, in most of the countries that cover large area, there are three types of distribution systems: urban, suburban, and rural. Each type of them has its own features regarding the length of the backbone, types of protection devices used,… Read more
Jul 08, 2020 | By Edvard Csanyi
How to shrink three-phase AC high voltage substation and optimize cost and space
Nowadays, when every cent is essential when building a substation, it is imperative to optimize each HV equipment without compromising functionality. This technical article deals with a few solutions to optimize high voltage switchgear in terms of space and cost…. Read more
Jul 06, 2020 | By Edvard Csanyi