Search

Premium Membership

Study specialized technical articles, papers & courses in low/high voltage fields. Save 50% on all courses at the EEP Academy with the Enterprise Plan.

Home / Technical Articles / 5 most common motor load types

Load profile (speed range, torque and power)

Certain load types are characteristic in the industrial world. Knowing the load profile (speed range, torque and power) is essential when selecting a suitable motor and frequency converter for the application.

5 most common motor load types
5 most common motor load types

Some common load types are shown. There may also be combinations of these types.

  1. Constant Torque
  2. Quadratic torque
  3. Constant power
  4. Constant power/torque
  5. Starting/breakaway torque demand

1. Constant torque

A constant torque load type is typical when fixed volumes are being handled. For example screw compressors, feeders and conveyors are typical constant torque applications.

Torque is constant and the power is linearly proportional to the speed.

Typical torque and power curves in a constant torque application
Figure 1 – Typical torque and power curves in a constant torque application

Go back to Types ↑


2. Quadratic torque

Quadratic torque is the most common load type. Typical applications are centrifugal pumps and fans. The torque is quadratically, and the power is cubically proportional to the speed.

Typical torque and power curves in a quadratic torque application
Figure 2 – Typical torque and power curves in a quadratic torque application

Go back to Types ↑


3. Constant power

A constant power load is normal when material is being rolled and the diameter changes during rolling. The power is constant and the torque is inversely proportional to the speed.

Typical torque and power curves in a constant power application
Figure 3 – Typical torque and power curves in a constant power application

Go back to Types ↑


4. Constant power/torque

This load type is common in the paper industry. It is a combination of constant power and constant torque load types. This load type is often a consequence of dimensioning the system according to the need for certain power at high speed.

Typical torque and power curves in a constant power/torque application
Figure 4 – Typical torque and power curves in a constant power/torque application

Go back to Types ↑


5. Starting/breakaway torque demand

In some applications high torque at low frequencies is needed. This has to be considered in dimensioning. Typical applications for this load type are for example extruders and screw pumps.

Typical torque curve in an application where starting torque is needed
Figure 5 – Typical torque curve in an application where starting torque is needed

Go back to Types ↑

Few More Words…

There are also several other load types. They are however hard to describe in a general presentation.

Just to mention a few, there are different symmetrical (rollers, cranes, etc.) and unsymmetrical loads. Symmetry/non-symmetry in torque can be for example as a function of angle or time. These kinds of load types must be dimensioned carefully taking into account the overloadability margins of the motor and the frequency converter, as well as the average torque of the motor.

Go back to Types ↑

Reference // Dimensioning of a drive system – ABB’s Technical guide

Premium Membership

Get access to premium HV/MV/LV technical articles, electrical engineering guides, research studies and much more! It helps you to shape up your technical skills in your everyday life as an electrical engineer.
More Information
author-pic

Edvard Csanyi

Electrical engineer, programmer and founder of EEP. Highly specialized for design of LV/MV switchgears and LV high power busbar trunking (<6300A) in power substations, commercial buildings and industry facilities. Professional in AutoCAD programming.

8 Comments


  1. Tarun Bagchi
    Jun 02, 2019

    Thank you very much for this informative article. Shall be delighted to get similar articles on different topics.


  2. KAISHNAIR A/L CHANGALI KUTTAN NAIR
    Sep 07, 2018

    Very useful information for electrical technitions

    Thanks alot.


  3. Rania ahmed
    May 02, 2018

    Many thanks for the precious informations we always have?


  4. Sameh
    May 01, 2018

    Thank you


  5. Evgeniy An
    May 21, 2017

    The main gragh for me is dependence the efficiency of motor from torque with a constant power. What abput 3 phase motor ?


  6. j
    Nov 09, 2015

    which is the best ac drive motors of 4 quadrant operations, such that, when loaded should be able to drive material such as coal blocks, to upside and down… and thanku for the information..


  7. Darshan Sukhadia
    Aug 24, 2015

    Very Useful Website for Electrical Engineers…It Refresh my knowledge everyday…and it covers every new topics also.


  8. Franklyn Linley
    May 25, 2015

    I find the site very interesting and informative. Thank you

Leave a Reply to j

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  ⁄  1  =  six

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).