Preparation for construction of MV lines

Stand alone overhead MV lines connect a stand alone generation system to load (LV and MV). Main components of stand alone MV network systems are: generation system, step up substation, MV network, step down transformer post.

Handbook for installation of MV lines in rural electricity systems
Handbook for installation of MV lines in rural electricity systems (photo credit: exponentialengineering.com)

The MV network can be overhead or underground type. In this handbook only overhead line will be considered further. The figure below shows an example of stand alone MV networks.

MV overhead line is built on supports, where the conductors are fixed on insulators.

Stand alone overhead MV network
Stand alone overhead MV network (click to expand)

Supports may be towers, poles, or other structures such as steel, concrete or wood. The choice of a type of support depends on the terrain to be crossed and the size of conductors and equipment to be carried. Availability and economy, as well as atmospheric elements determine the choice of material.

Poles may be wooden, reinforced concrete or steel frame type. Reinforced concrete poles are considered as most economic. As supporting structure, poles are characterized by its length (height) and strength.

Cross sections of reinforced concrete pole are of rectangular or circle types. To comply with the clearance of overhead line in Cambodia, the length of 12m and 14 m are sufficient. The factory produces poles with strength of 3 kN, 5 kN, 8 kN and so on.


Pole accessories

Crossarms are usually made of galvanized steel. The usual cross-sectional dimensions for distribution crossarms are 0.09m by 0.1m. Their length depending on the number and spacing of pins. Heavier arms of varying lengths are used for special purposes, usually holding the heavier transmission conductors and insulators.

Distribution line crossarms
Distribution line crossarms

When a heavy loading is usually encountered, as at corner or junction poles, double arms, that is, one on each side of the pole, may be required. Note: For ABC type cable, the fixing structures are very simplified.

Title:Handbook for installation of MV lines – For rural electricity service constructors and operators Mr. Ky Chanthan, Mr. Theng Marith
Format:PDF
Size:2.5 MB
Pages:106
Download:Here 🔗 (Get Premium Membership) | Video Courses | Download Updates

Good Reading – The Challenging Job of an Electrical Commissioning Engineer

The Challenging Job of an Electrical Commissioning Engineer (Activities and Real World Examples)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount 💥 - Save 50% on all 90+ video courses with Enterprise Membership plan.

More Information

4 Comments


  1. Njuki Godfrey
    Sep 06, 2021

    The book will help me as a new small scale contractor. S.JEC TECHNICAL SERVICES UGANDA LTD


  2. Esubalew Bahiru
    Apr 03, 2021

    Please send me all mv, lv& transfomer erection standard ?tanks for good help


  3. Luis Fernandez
    Nov 14, 2017

    Thanks


  4. Grant Chiyangi
    Aug 09, 2016

    The book is very interesting but I am falling to download it, how can I go about it?

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

90  ⁄  9  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.