Why test circuit breaker

Circuit breaker is one of the most important component in every electric power system. The circuit breaker has to operate within extremely tight tolerances when a disturbance is detected in the network to protect sensitive and costly components such as transformers.

Guidelines for HV circuit breaker function and test methods
Guidelines for HV circuit breaker function and test methods

Some of the most important of the many reasons for testing circuit breakers are to ensure they:

  • Provide protection for expensive equipment
  • Prevent outages that lead to loss of income
  • Ensure reliability of the electricity supply
  • Prevent downtime and darkness
  • Verify breaker performance

Substation breaker testing is an important task for any power utility. The breakers are there to facilitate the flow of current during normal operation and to interrupt current flow in the event of a fault. However, all electrically operated devices are, sooner or later, likely to experience some kind of failure. That failure can be caused by many factors, including ageing and external faults.

The power utility operator has to be prepared and have a plan in place to handle every situation!

This document will help readers to understand what is involved with keeping circuit breakers operating at peak performance. Breakers are mechanically sophisticated devices requiring periodic adjustments. The need for some of these adjustments can be determined visually and they can be given the attention needed without testing.

However, in most cases, it will be necessary to carry out electrical testing to find out what is the cause of out-of-tolerance conditions. This guide primarily deals with electrical testing.

An overview of the components in a power grid system
An overview of the components in a power grid system

HV Circuit Breakers in a transmission scheme can be viewed as forming a tree starting with the generating station, fanning out to the transmission grid, to the distribution grid, and finally to the point of consumption.

The task for the utility is to generate power, transmit it and distribute it with maximum availability. While doing this, it is imperative that losses are kept to a minimum, and acceptable levels of power quality and safety are maintained.

All of this must be done in an environmentally friendly manner! Breakers play an important part in making this happen. High voltage circuit breakers are extremely important for the function of modern electric power supply systems.

The breaker is the active link that ultimately has the role of quickly opening the primary circuit when a fault occurs.

Often, the breaker has to perform its duty within some tens of milliseconds, after months, perhaps years of idly being in circuit.

Since RCM (reliability centered maintenance) and condition based maintenance have become the established strategies for most owners and operators of electric power delivery systems, the need for reliable and accurate test instruments for eld use is clear.

Title:Guidelines for HV circuit breaker function and test methods – Megger
Format:PDF
Size:4.9 MB
Pages:52
Download:Right here | Video Courses | Membership | Download Updates
Guidelines for HV circuit breaker function and test methods - Megger
Guidelines for HV circuit breaker function and test methods – Megger

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount - Save 50% on all 110+ video courses with Enterprise Membership plan.

More Information

2 Comments


  1. Kabelo Mokgothu
    Jan 27, 2023

    I am interested in your services and information


  2. fortune masunda
    Mar 16, 2022

    Very Helpful, thank you very much!

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.