Home / Download Center / Electrical Engineering Books and Technical Guides / Relay control and protection guides / Basic principles in modern substation automation protection systems you MUST know

Substation automation and protection

This guide outlines some of the principles used in modern substation automation protection systems, as well as some of the underlying theory. The increasing sophistication of protection schemes coupled with the advancement of technology and the desire for vendor interoperability has resulted in standardization of networks and data interchange within substations.

Basic principles in modern substation automation protection systems
Basic principles in modern substation automation protection systems

Today, devices within substations use standardized protocols for communication. Furthermore, substations can be interconnected with open networks, such as the internet or corporate-wide networks, which use standardized protocols for communication.

This introduces a major security risk making the grid vulnerable to cyber-attacks, which could in turn lead to major electrical outages.


Distance protection

Simple forms of overcurrent protection have the advantage of being simple and cost effective, but they have one major disadvantage – they are prone to maloperation! This is acceptable for low voltage distribution (LV systems), because the only thing at risk is continuity of supply to consumers.

Although inconvenient to the consumer, this risk is considered acceptable.

EHV systems on the other hand, are part of a large and complex interconnected grid, where maloperation of protection devices can severely jeopardize grid stability.

Major cascading blackouts, as recently seen in Europe and the USA, are examples of what can happen when electrical power grids become unstable. It is therefore essential that a more reliable form of protection is implemented on EHV systems.

Fault type reach
Fault type reach (click to expand diagram)

The β€œreach” of an IED is defined as the maximum electrical distance at which the IED should operate. This may vary from a few meters to a few kilometers, depending on the type of protection that the designated IED is assigned to.

The reach of an overcurrent IED is dependent on several factors, but the one we need to consider here is the line impedance. Because the line impedance increases the further the fault is away from the source, the fault current decreases correspondingly.

Now, a three-phase fault will give rise to a larger fault current than a Line-Line-Ground (L-L-G) fault in the same location, due to its higher voltage. Likewise, an L-L-G fault will give rise to a larger fault current than an L-G fault.

Now it becomes clear that the reach of an IED is dependant on fault type, in addition to other factors such as source impedance.

So if we wish to set the reach such that the IED protects fault in the region of the busbar B, depending on the fault type, it may well underreach, in which case the required circuit breaker will not trip, or overreach, in which case we may cause a circuit breaker outside the protection zone to trip.

Title:Principles used in modern substation automation protection systems – Michael Bergstrom, Alstom
Format:PDF
Size:1.1 MB
Pages:65
Download:Here πŸ”— (Get Premium Membership) | Video Courses | Download Updates

Good Reading – The Challenging Job of an Electrical Commissioning Engineer

The Job of an Electrical Commissioning Engineer (Activities and Real World Examples)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount - Save 50% on all 110+ video courses with Enterprise Membership plan.

More Information

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.