Home / Technical Articles / Main components of a Gas Insulated Substation (GIS) you should know about

GIS components

Gas-insulated substations (GIS) use circuit breakers, disconnect switches, and grounding switches, and have various means of indicating their position, either opened or closed, so the same as in air-insulated substation (AIS).

Main components of a Gas Insulated Substation (GIS) you should know about
Main components of a Gas Insulated Substation (GIS) you should know about

Operation of a GIS uses most of the same principles as operating an air insulated substation (AIS) although the various active components are physically configured differently. The first obvious difference is that the blades of the disconnect switches and the grounding switches used in a GIS are surrounded by grounded metallic enclosures.

This enclosure prevents the blades from being readily and easily visible to determine their fully opened or fully closed position. The second obvious difference relates to the bus conductors being located inside grounded metallic enclosures.

These enclosures prevent the bus from being grounded with portable personnel grounds except at very discrete locations, such as air-to-gas bushing terminations at transmission lines and transformer banks.

Generally a GIS requires more extensive electrical interlocking between the circuit breakers, disconnect switches (isolators), and grounding switches. The specific detailed method of operating and interlocking is generally specified by the ultimate user of the GIS.

Contents:

  1. Circuit Breaker
  2. Disconnect Switches
  3. Nonfault-Initiating Grounding Switches
  4. High Speed (Fault-Initiating) Grounding Switches
  5. Three-Position Disconnect/Grounding Switches
    1. Voltage Transformers (VTs)
    2. Current Transformers (CTs)
  6. Switch Viewports
  7. Gas Compartments and Zones
  8. Interlocking
  9. Local Control Cabinets (LCCs)

Membership Upgrade Required

This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.

With EEP’s premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.

Black Friday Deal đź’Ą – Save 20% on Pro Plan with code BLACKFRIDAY

Upgrade

Already a member? Log in here

Premium Membership

Get access to premium HV/MV/LV technical articles, electrical engineering guides, research studies and much more! It helps you to shape up your technical skills in your everyday life as an electrical engineer.
More Information
Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Edvard Csanyi

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Profile: Edvard Csanyi

Leave a Comment

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

4  ×    =  40

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Save 20% with coupon BLACKFRIDAY.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.