Cable fault localization techniques

The long distance underground cables are the nerves of a Railway Signaling or Telecom system. If the cables connected with the system are healthy and free from any defect, it will run smoothly and efficiently. Any fault in the cable may affect the connected circuit or equipment and paralyze the train operation.

A guide to cable fault localization in railways
A guide to cable fault localization in railways (photo credit: Warna RS Sdn. Bhd.)

Locating the cable fault by conventional methods and repairing thereafter are time consuming and require substantial manpower. The repercussions for these failures may be in the form of punctuality losses and high maintenance cost to the Railways. To save time, manpower and at the same time reduce cost and downtime, Railways need to adopt innovative techniques in cable fault localization.

With the advent of advanced Electronics and Communication technology, equipment have been developed over the years which can accurately locate faults in underground cables.

Underground cables play an important role in keeping the system operational by carrying different circuits through them. Although every safety precaution is taken for the safety of cable while laying it underground, unpredictable faults in a cable due to various reasons are not ruled out.

The type of fault for example earth, open, short or low insulation fault in underground cables can be detected easily with the help of a megger. But finding the exact location of the cable fault needs special techniques.

Figure 1 – Cable fault locator

Cable fault locator
Figure 1 – Cable fault locator

Cable Fault Localization

Introduction

There are hundreds of trains which run daily on Indian Railways and the various systems which are involved in the operation of trains are Track, Rolling stock, Loco, Electrical Traction, Signaling and Telecom and traffic control systems.

Railway Signaling and Telecom circuits run on hundreds of kilometers of underground cables. Although adequate precautions are taken in lying of cables beneath the ground and underground cables are not affected by any adverse weather condition like pollution, heavy rainfall, snow and storm etc. there are other factors which may cause faults in the cables.


Type of Cables carrying S&T circuits

Signaling cables

PVC insulated PVC sheathed and armoured signalling cables. Generally, used copper conductor core sizes are 1.5 sq.mm. and 2.5sq.mm. Most commonly used cores are 2C, 4C, 6C, 8C, 9C, 12C, 19C, 20C, 24C & 30C.


Telecom cables

  • Polyethylene Insulated Jelly Filled (PIJF) cables
  • 4 or 6 Quad cables (Core size 0.9 mm)
  • Co-Axial Cables

1.3 Major causes of cable fault

Some of the causes of cable faults are as given below:

  1. Ageing.
  2. Corrosion of sheath.
  3. Moisture in the insulation.
  4. Heating of cable.
  5. Fire and lightning surges.
  6. Electrical puncture
  7. Damage during laying.
  8. Damage while in use due to excavation works.

1.4 Types of cable faults

The common faults which develop in the conductors of multi-core cables are:


Earth fault

When any of the conductors of the cable comes in contact with the earth, it is called an earth fault. This type of fault allows the current, carried by the conductor to leak to the earth directly or indirectly instead of going to the apparatus to which the conductor is connected.

This usually occurs when the outer sheath is damaged due to chemical reactions with soil or due to vibrations and mechanical crystallization.

Figure 2 – Locating cable earth fault

Locating cable earth fault
Figure 2 – Locating cable earth fault

Short circuit fault

When two or more conductors of a multi-core cable come in contact with each other, then this is called a short circuit fault. A short-circuit fault occurs when the individual insulation of the conductor core is damaged.

Figure 3 – Locating cable short circuit fault

Locating cable short circuit fault
Figure 3 – Locating cable short circuit fault

Open circuit fault

As the name suggests, this fault involves an open circuit in the conductors. When one or more cable conductors (cores) break, it leads to discontinuity. This discontinuity also occurs when the cable comes out of its joint due to mechanical stress.

This is known as Open circuit fault.

Figure 4 – Locating open circuit fault

Locating open circuit fault
Figure 4 – Locating open circuit fault

Low insulation fault

Sometimes when the cable core insulation material is deteriorated by ageing, moisture, excessive heating or dirt the insulation resistance is dropped to very low value (several hundred to several kilo ohms) it is called as low insulation fault.

But if the insulation resistance is of the order of mega ohms and less than 2 Mega Ohms it is termed as high resistance fault or bad insulation. In both the cases, the quality of communication or flow of current through the cable is badly affected and the cable needs replacement.

The need for cable fault localization

Whenever a fault occurs in one or more conductors of underground cable, be it an earth fault, open/short circuit fault or low insulation fault, the circuit completing through the conductor or conductors is interrupted which in turn affects the functioning of connected equipment.

In a railway signaling system the operation of signals or its associated equipment is badly affected due to cable fault.

Similarly if a cable fault occurs in a telecom cable, the circuits associated with Block working, Control or other communication systems may not work. Unless the fault is identified and rectified, the train movement is badly disrupted.

Title:Cable Fault Localization Guide – Government Of India Ministry Of Railways
Format:PDF
Size:3.70 MB
Pages:62
Download:Right here | Video Courses | Membership | Download Updates
Cable Fault Localization Guide
Cable Fault Localization Guide

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
50% Discount - Save 50% on all 110+ video courses with Enterprise Membership plan.

More Information

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.