Electric Circuits
Showing all 11 results
-
Electrical On-Site Installations Course: Steps in Execution Stages
28.45 $ Learn how electrical installations are done on-site during execution stages. Learn how cable conduits are installed and how distribution boards and capacitor banks are wired and installed. Learn how l...Add to cart -
Practice Problems for DC Branch-Current Analysis
18.45 $ Learn the basic concepts of electricity, its laws, theorems, and DC circuits by solving 12 problems and their solutions focusing on DC series-parallel networks. The course consists of one big lesson, ...Add to cart - Sale!
The Fundamentals of AC and DC Circuit Analysis (Two Courses)
39.90 $ This bundle introduces the fundamental concepts of electrical direct current and alternating circuits, which form the basis of all electrical and electronic systems (sinusoidal waveforms, vectors and ...Add to cart -
Learn to Read and Analyze Circuit Breaker Schematics and Control Wiring Diagrams
28.45 $ This is an intermediate to advance level course dedicated to schematics and control wiring diagrams of high-voltage and medium-voltage circuit breakers (applicable to power substations, switchyards, p...Add to cart -
Advanced Analysis and Power Calculations of AC Electric Circuits
23.45 $ Learn everything about AC electric circuits and electronics, from the basics such as what sinusoids are, all the way to key characteristics of AC circuits such as impedance, admittance, power factor, ...Add to cart -
Digital Electric Circuits and Digital Logic for Intelligent Electrical Devices (IEDs)
23.45 $ This is course is dedicated to digital logic which is the foundation for modern relay protection and IEDs (Intelligent Electrical Devices). You will learn binary numbers and binary arithmetic, logic g...Add to cart -
AC Circuits Analysis: Real, Reactive and Complex Power Calculation
21.45 $ Learn how to use real, reactive, and complex power in the analysis of AC circuits. Learn how to calculate power factor correction (PFC) and power in three-phase circuits. 9 lessons in 3h 38min total c...Add to cart -
AC Circuit Analysis: Fundamentals Course for Electrical Engineers
18.45 $ This course will provide the student with the basic understanding of working with circuits involving Alternation Current, which includes sinusoidal waveforms, vectors and phasors. The final exam and c...Add to cart -
The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included)
28.45 $ This course introduces the fundamental concepts of electrical direct current (DC) circuits (Ohm’s Law, Kirchhoff's Laws, Series and Parallel Circuits, etc.) and the most common practice problems stu...Add to cart -
Fundamental Electric Circuits and Electronics Course for Beginner Engineers
28.45 $ Learn fundamentals of electric circuits and electronics, starting from the basics such as what an electric circuit is, electrical quantities like voltage, current & power, all the way to analyzing ele...Add to cart -
Ultimate Electric Circuits Course for Electrical Engineers
18.45 $ Learn the fundamentals of electric circuits from scratch with dozens of examples for electrical engineering students. This course consists of 134 lectures and over 10h total length.