{"id":18577,"date":"2023-04-06T23:54:32","date_gmt":"2023-04-06T21:54:32","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=18577"},"modified":"2023-04-06T23:54:32","modified_gmt":"2023-04-06T21:54:32","slug":"course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking\/","title":{"rendered":"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits"},"content":{"rendered":"<p>This course brings the essence of a medium voltage switchgear and its control and protection schematics. It focuses on the study of MV panel control and protection schematics and is structured so that no prior knowledge of schematics is assumed. The instruction is broken down into five sections, each of which is dedicated to the\u00a0<strong>explanation of a different schematic<\/strong>, such as tripping, trip circuit supervision, interlocking, indication circuits, and others.<\/p>\n<p>Three busbars and two bus sections make up the study\u2019s instance of an 11kV medium voltage switchgear\u2019s single bus and single breaker arrangement. Each bus receives power from its own individual 132\/11kV Power transformer, and an\u00a0<strong>automatic bus transfer scheme is used<\/strong>, with the use of a numerical relay.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/804194070?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<div class=\"wp-block-spacer\" aria-hidden=\"true\"><\/div>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/804193781?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<div class=\"wp-block-spacer\" aria-hidden=\"true\"><\/div>\n<p>This course begins with the fundamentals and progresses to more complex topics. The emphasis is on providing the information that can be used immediately. As a first step, we\u2019ll study together how to draw\u00a0<strong>simple line diagrams and interpret their meaning<\/strong>. This course will equip you with the knowledge to read, understand, and interpret medium-voltage switchgear diagrams.<\/p>\n<p>The training comes with a bonus: detailed diagrams of common feeder types.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/804195502?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<div class=\"wp-block-spacer\" aria-hidden=\"true\"><\/div>\n<p>One of the most important skills in engineering is the ability\u00a0<strong>to understand various types of drawings<\/strong>. Engineering drawings are the backbone of any industry-standard procedure for communicating complex data necessary for setting up, troubleshooting, maintaining, and operating a system.<\/p>\n<p>Becoming familiar with the typical practices and fundamental symbols used in such drawings is the initial step in learning to interpret them.<\/p>\n<p>As a result of my 18 years working in MV commissioning, design review, and testing, I have developed this course, broken down the schematics, and pointed out design defects and improvements. As a result, you will learn not only to interpret the schematics, but also\u00a0<strong>to conduct a thorough design assessment of medium-voltage switchgear<\/strong>\u00a0with the help of the guidelines provided in this course.<\/p>\n<div class=\"wp-block-spacer\" aria-hidden=\"true\"><\/div>\n<div class=\"wp-block-spacer\" aria-hidden=\"true\"><\/div>\n<h2>What you will learn from this course?<\/h2>\n<div class=\"is-layout-flex wp-container-3 wp-block-columns\">\n<div class=\"is-layout-flow wp-block-column\">\n<ul>\n<li>Understanding Single Line Diagrams<\/li>\n<li>Circuit Breaker Anti-Pumping Scheme<\/li>\n<li>Circuit Breaker Anti-Slam Scheme<\/li>\n<li>Seal in contacts<\/li>\n<li>Trip command duration<\/li>\n<li>Coordination of trip command duration<\/li>\n<li>Motor control circuit<\/li>\n<li>Spring charge indication<\/li>\n<li>Concept of limit switch<\/li>\n<li>Philosophy of auxiliary contacts<\/li>\n<li>How NO contact works, Normally Open contacts<\/li>\n<li>How NC contact works, Normally Close contacts<\/li>\n<li>52a &amp; 52b Contacts<\/li>\n<li>Binary input circuit<\/li>\n<li>Limit switches operation<\/li>\n<li>Trip &amp; closing coil save contacts<\/li>\n<li>How loops are form in schematic<\/li>\n<li>DC Supply supervision &amp; DC loop supervision<\/li>\n<li>How trip circuit supervision works<\/li>\n<li>Supervision of tripping coil in case CB is open and close position<\/li>\n<li>Concept of fake DC, return DC and solid DC<\/li>\n<li>ABB trip circuit supervision relay<\/li>\n<li>MVAX trip circuit supervision relay<\/li>\n<li>DC supply schematics<\/li>\n<li>Fuse Fail Relays, how they work<\/li>\n<li>Control operations, Local, Remote, Emergency and Remote schematics<\/li>\n<\/ul>\n<\/div>\n<div class=\"is-layout-flow wp-block-column\">\n<ul>\n<li>How control is transferred from lowest level to highest level<\/li>\n<li>Indication circuit, single point and double point indications<\/li>\n<li>Technique of contact multiplication and where it should be allowed.<\/li>\n<li>Trip circuit 1 &amp; 2 for Incomer, Outgoing feeder, bus section, capacitor bank feeder<\/li>\n<li>Introduction to mechanical &amp; electrical interlocks<\/li>\n<li>Test &amp; Service positions<\/li>\n<li>Closing Circuit of the Circuit breaker<\/li>\n<li>Closing interlocks for incomer with protection &amp; upstream devices<\/li>\n<li>Closing interlocks for outgoing feeder<\/li>\n<li>Closing interlocks for capacitor bank feeder<\/li>\n<li>Interlocks for test &amp; service positions<\/li>\n<li>DC supply supervision scheme<\/li>\n<li>Feeders interlock with busbar earth switch<\/li>\n<li>Busbar earth switch interlock with feeders<\/li>\n<li>Busbar Earth Switch control<\/li>\n<li>Busbar VT schematics<\/li>\n<li>Bus Section Trip circuit schematics<\/li>\n<li>What is lockout(86) relays<\/li>\n<li>Lockout circuits of incomer\/outgoing feeder\/ bus section\/ capacitor bank<\/li>\n<li>Capacitor bank door interlock circuit<\/li>\n<li>Single line diagram of incoming, outgoing, bus section and capacitor bank feeder<\/li>\n<li>Bus section interlocks<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<div class=\"is-layout-flex wp-container-6 wp-block-columns\">\n<div class=\"is-layout-flow wp-block-column\">\n<h2>Course Summary:<\/h2>\n<ol>\n<li>MV Switchgear SLD and Symbols, Components, Auxiliary Contacts<\/li>\n<li>Motor Charging and Anti-Pumping Circuits, Local-Remote Logic<\/li>\n<li>MV Schematics: Tripping Coils, Test Switch, Test Circuit Supervision and Interlocking<\/li>\n<li>Incoming Feeder: SLD, Closing, Tripping &amp; Indication Circuits and Interlocking<\/li>\n<li>Bus Section, Capacitor Bank, Busbar VT and Busbar Earth Switch<\/li>\n<\/ol>\n<\/div>\n<div class=\"is-layout-flow wp-block-column\">\n<h2>Who Is This Course For:<\/h2>\n<ul>\n<li>Substation engineers<\/li>\n<li>Practicing power system engineers<\/li>\n<li>Maintenance staff<\/li>\n<li>Electrical engineering students planning on pursuing a career in power engineering<\/li>\n<li>Power system protection engineers<\/li>\n<\/ul>\n<h2>Requirements:<\/h2>\n<ul>\n<li>The basics of power systems<\/li>\n<li>Knowledge of basic substation terms<\/li>\n<li>Understanding the basic relay protection terminology and principles<\/li>\n<li>Passion and patience for learning.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This masterclass course provides a deep knowledge, understanding and analysis of various control and protection schematics of an medium-voltage switchgear, such as tripping, trip circuit supervision, interlocking, indication circuits, and many others. Detailed diagrams of common feeder types are included. The course consists of 5 chapters, 74 lessons and 12h 50min. total length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits\">See course details<\/a><\/div>\n","protected":false},"author":11,"featured_media":18578,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[649,160,117],"product_tag":[1613,1620,1622,1624,1625,1094,1623,936,1473,1481,1619,1618,1583,1615,1614,1621,1218,1617,1616],"class_list":["post-18577","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-panel-design","product_cat-power-substation","product_cat-relay-protection","product_tag-anti-pumping-scheme","product_tag-automatic-bus-transfer","product_tag-bus-section","product_tag-busbar","product_tag-busbar-earth-switch","product_tag-capacitor-bank","product_tag-capacitor-bank-feeder","product_tag-circuit-breaker","product_tag-drawings","product_tag-incomer","product_tag-indication-circuits","product_tag-interlocking-circuits","product_tag-interlocks","product_tag-medium-voltage-switchgear","product_tag-motor-control-circuit","product_tag-outgoing-feeder","product_tag-single-line-diagrams","product_tag-trip-circuit-supervision","product_tag-tripping-circuits","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Course dedicated to medium-voltage switchgear schematics such as tripping, trip circuit supervision, interlocking, and indication circuits.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Course dedicated to medium-voltage switchgear schematics such as tripping, trip circuit supervision, interlocking, and indication circuits.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/04\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"805\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking\",\"name\":\"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg\",\"datePublished\":\"2023-04-06T21:54:32+00:00\",\"description\":\"Course dedicated to medium-voltage switchgear schematics such as tripping, trip circuit supervision, interlocking, and indication circuits.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2023\\\/04\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg\",\"width\":1000,\"height\":805,\"caption\":\"Course to MV Switchgear Schematics: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits - EEP Academy Courses","description":"Course dedicated to medium-voltage switchgear schematics such as tripping, trip circuit supervision, interlocking, and indication circuits.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking","og_locale":"en_US","og_type":"article","og_title":"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits - EEP Academy Courses","og_description":"Course dedicated to medium-voltage switchgear schematics such as tripping, trip circuit supervision, interlocking, and indication circuits.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","og_image":[{"width":1000,"height":805,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/04\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking","name":"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/04\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg","datePublished":"2023-04-06T21:54:32+00:00","description":"Course dedicated to medium-voltage switchgear schematics such as tripping, trip circuit supervision, interlocking, and indication circuits.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/04\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/04\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking-indication-circuits-WOO.jpg","width":1000,"height":805,"caption":"Course to MV Switchgear Schematics: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mv-switchgear-schematics-tripping-trip-circuit-supervision-interlocking#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"MV Switchgear Schematics Course: Tripping, Trip Circuit Supervision, Interlocking and Indication Circuits"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/18577","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=18577"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/18578"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=18577"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=18577"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=18577"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=18577"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}