{"id":20384,"date":"2023-11-07T17:16:57","date_gmt":"2023-11-07T16:16:57","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=20384"},"modified":"2023-11-07T17:16:58","modified_gmt":"2023-11-07T16:16:58","slug":"course-transformers-design-applications-protection-testing-diagnostics","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics\/","title":{"rendered":"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics"},"content":{"rendered":"<p>In this masterclass, you will learn everything there is to know about electrical power transformers, beginning with the operation, theory, and design of three phase transformers. From there, you will learn about the various types of transformers and their applications in the electric network. The course\u00a0will conclude with a comprehensive study on transformer protection, testing, and commissioning.<\/p>\n<p>As a result, the objective of this course is to teach you all you need to know\u00a0<strong>to become an expert<\/strong>\u00a0in the field of electric power transformer engineering.<\/p>\n<p>The course consists of\u00a0<strong>17 lessons and 163 topics<\/strong>. It takes 26 hours and 18 minutes in total duration.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/866022992?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p>The course is organized in the following manner:<\/p>\n<p>Firstly, the course provides a comprehensive introduction to the theory and functioning of transformers (theory of operation, phasor diagram, etc.). The evaluation of transformer performance will be the subject of the following Section 3, which will cover subtopics such as transformer losses (hysteresis losses, eddy current), regulation and efficiency.<\/p>\n<p>Construction, types, and connections of three-phase transformers,\u00a0<strong>per phase, per unit analysis, and vector groups<\/strong>\u00a0is covered in Section 4.<\/p>\n<p>After that, in Section 5, you will acquire knowledge regarding the manufacturing and construction of power transformers, including an explanation of each transformer component. Section 6 covers different factors that affect the transformer operation (temperature rise, loading, harmonics, inrush current, etc.).<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/866032826?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p>A complete study of different types of transformers and their applications in power systems is covered in Section 7. Section 8 is dedicated to transformer protection, where you will learn how to identify different transformer faults and provide a suitable protection device for this type of fault.<\/p>\n<p>In Section 9, you will learn about\u00a0<strong>transformer testing, commissioning, and diagnostics<\/strong>, where we will perform routine, type, and special tests on power transformers to ensure the healthiness of the transformer before its energization on the site. Tests such as insulation resistance (IR), tan delta, partial discharge, Hi-Pot, Induced and impulse voltage tests and others are covered in detail.<\/p>\n<p>Finally,\u00a0<strong>complete MATLAB simulations<\/strong>\u00a0are performed on single-phase and 3-phase electrical transformers.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/866026263?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Course Summary:<\/h2>\n<ol>\n<li>Introduction and Download Materials<\/li>\n<li>Transformer Theory<\/li>\n<li>Transformer Performance<\/li>\n<li>Three-Phase Transformers<\/li>\n<li>Transformer Construction<\/li>\n<li>Factors Affecting Transformer Operation<\/li>\n<li>Power and Distribution Transformers<\/li>\n<li>Current Transformers (CTs)<\/li>\n<li>Voltage Transformers (VTs)<\/li>\n<li>Auto Transformers<\/li>\n<li>Special Transformer Types<\/li>\n<li>Transformer Protection<\/li>\n<li>Tests on Transformer Insulation<\/li>\n<li>Tests on Transformer Oil<\/li>\n<li>Tests for Transformer Parameters<\/li>\n<li>MATLAB Simulink Projects on Single-Phase Transformer<\/li>\n<li>MATLAB Simulink Projects on Three-Phase Transformer<\/li>\n<\/ol>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For:<\/h2>\n<ul>\n<li>Substation engineers<\/li>\n<li>Practicing power system engineers<\/li>\n<li>Maintenance staff<\/li>\n<li>Electrical engineering students planning on pursuing a career in power engineering<\/li>\n<li>Power system protection engineers<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">Requirements:<\/h2>\n<ul>\n<li>The basics of power systems<\/li>\n<li>Knowledge of basic substation terms<\/li>\n<li>Understanding the basic relay protection terminology and principles<\/li>\n<li>Passion and patience for learning.<\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected, and how to test and perform diagnostics. The course consists of 17 lessons and 163 topics. It takes 26h and 18min it total duration.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/transformers-electrical-networks-design-applications-protection-testing-diagnostics\">See course details<\/a><\/div>\n","protected":false},"author":2426,"featured_media":20386,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1030,160,145,117,400,116],"product_tag":[1698,963,1699,1700,1701,1702,1703,1704,189,1705,1706,1707,1708,1709,1710,1366],"class_list":["post-20384","product","type-product","status-publish","has-post-thumbnail","product_cat-power-engineering","product_cat-power-substation","product_cat-power-system","product_cat-relay-protection","product_cat-transformers","product_cat-transmission-and-distribution","product_tag-auto-transformers","product_tag-current-transformers","product_tag-distribution-transformers","product_tag-eddy-current","product_tag-hysteresis-losses","product_tag-insulation-resistance","product_tag-power-transformers","product_tag-three-phase-transformers","product_tag-transformer","product_tag-transformer-insulation","product_tag-transformer-losses","product_tag-transformer-operation","product_tag-transformer-parameters","product_tag-transformer-testing","product_tag-transformer-theory","product_tag-voltage-transformers","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-07T16:16:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/11\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"866\" \/>\n\t<meta property=\"og:image:height\" content=\"608\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics\",\"name\":\"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg\",\"datePublished\":\"2023-11-07T16:16:57+00:00\",\"dateModified\":\"2023-11-07T16:16:58+00:00\",\"description\":\"Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg\",\"width\":866,\"height\":608,\"caption\":\"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-transformers-design-applications-protection-testing-diagnostics#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics - EEP Academy Courses","description":"Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics","og_locale":"en_US","og_type":"article","og_title":"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics - EEP Academy Courses","og_description":"Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected...","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2023-11-07T16:16:58+00:00","og_image":[{"width":866,"height":608,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/11\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics","name":"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/11\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg","datePublished":"2023-11-07T16:16:57+00:00","dateModified":"2023-11-07T16:16:58+00:00","description":"Learn all kinds of transformer you can find in various electrical networks, their design, where they are applied, how they are protected...","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/11\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2023\/11\/course-transformers-electrical-networks-design-applications-protection-testing-diagnostics.jpg","width":866,"height":608,"caption":"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-transformers-design-applications-protection-testing-diagnostics#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Transformers In Electrical Networks: Design, Applications, Protection, Testing and Diagnostics"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/20384","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/2426"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=20384"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/20386"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=20384"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=20384"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=20384"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=20384"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}