{"id":20990,"date":"2024-02-13T23:53:11","date_gmt":"2024-02-13T22:53:11","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=20990"},"modified":"2024-02-13T23:53:38","modified_gmt":"2024-02-13T22:53:38","slug":"course-mastering-transformer-vector-groups","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups\/","title":{"rendered":"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections"},"content":{"rendered":"<p>Learn the essentials of transformer connections \u2013\u00a0<strong>vector groups<\/strong>. The course starts with the vector and phasor basics and their difference. What phase shift and phase angle are and how phase shift is created in a transformer are covered in detail in the following lessons.<\/p>\n<p>The course consists of 15 lessons and\u00a0<strong>1h 26 min. total duration<\/strong>.<\/p>\n<p>You will learn why transformers are connected to form specific vector groups, the delta and star connections, and the relationship between line and phase voltages and current. What are the advantages and disadvantages of connecting transformer winding in Star or Delta? The answers are covered in great detail.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/910322879?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p>We will discuss the\u00a0<strong>26 MVA transformer nameplate<\/strong>.<\/p>\n<p>The course continues with defining vector group dy11, clock method, lead and lag concepts. Finally, you will learn to draw vector group and connections of\u00a0<strong>dy11,dy1, yd1, yy0,dd0, yy6, and yz1<\/strong>\u00a0configurations.<\/p>\n<div class=\"info_box\">Upon completion of this course, you will have the ability to comprehend and establish correlations\u00a0<strong>within any vector group of transformers<\/strong>.<\/div>\n<p><strong>The following topics are covered in this masterclass:<\/strong><\/p>\n<ol>\n<li>What is vector<\/li>\n<li>What is phasor<\/li>\n<li>Difference between vector and phasor<\/li>\n<li>What is phase shift &amp; phase angle<\/li>\n<li>How phase shift is created in transformer<\/li>\n<li>Why transformer with different phase shift exist<\/li>\n<li>Why at least one delta winding is provided<\/li>\n<li>Circuit breaker auxiliary contacts<\/li>\n<li>Why transformers are connected to form certain vector group<\/li>\n<li>What is delta and star connection and relationship of line and phase voltages and current<\/li>\n<li>Advantage and disadvantage of connecting transformer winding in star or delta<\/li>\n<li>Where to place HT windings, LT windings and tap changer windings<\/li>\n<li>Discuss 26MVA transformer name plate<\/li>\n<li>How to define vector group i.e. dy11<\/li>\n<li>What is clock method, lead and lag concept<\/li>\n<li>Draw vector group and connections of dy11, dy1, yd1, yy0,dd0, yy6 and yz1<\/li>\n<\/ol>\n<div class=\"wp-block-spacer\" aria-hidden=\"true\"><\/div>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For<\/h2>\n<ol>\n<li>Electrical Engineering Students<\/li>\n<li>Electrical Engineering Graduates<\/li>\n<li>Electrical Engineers who work in the field of substations and transformers<\/li>\n<li>Electrical Control Engineers<\/li>\n<li>Power\/Utility Engineers<\/li>\n<li>Technicians<\/li>\n<\/ol>\n<h2 class=\"wp-block-heading\">Requirements<\/h2>\n<ul>\n<li>Basic knowledge of transformers<\/li>\n<li>A good will for learning<\/li>\n<li>A cup of coffee<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This masterclass course provides a deep knowledge, understanding and analysis of transformer vector group connections and phasors. You will learn to analyze and draw connections of transformer windings. The course consists of 15 lessons and 1h 36 min. total duration.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/mastering-transformer-vector-groups-analyze-draw-windings-connections\">See course details<\/a><\/div>\n","protected":false},"author":11,"featured_media":20995,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[160,145,332,116],"product_tag":[1795,1791,1782,1788,1797,1787,1796,1785,1780,1794,1779,1784,1778,1783,1781,1786,1777,1776,1789,1798,1790,1792,1793],"class_list":["post-20990","product","type-product","status-publish","has-post-thumbnail","product_cat-power-substation","product_cat-power-system","product_cat-protection","product_cat-transmission-and-distribution","product_tag-clock-method","product_tag-dd0","product_tag-delta-connection","product_tag-dy1","product_tag-dy1-vector-group","product_tag-dy11","product_tag-dy11-vector-group","product_tag-line-voltages","product_tag-phase-angle","product_tag-phase-rotation","product_tag-phase-shift","product_tag-phase-voltages","product_tag-phasor","product_tag-star-connection","product_tag-transformer-connections","product_tag-transformer-nameplate","product_tag-transformer-vector-groups","product_tag-vector-group","product_tag-yd1","product_tag-yd1-connection","product_tag-yy0","product_tag-yy6","product_tag-yz1","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections - EEP Academy Courses<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"This masterclass course provides a deep knowledge, understanding and analysis of transformer vector group connections and phasors. You will learn to analyze and draw connections of transformer windings. The course consists of 15 lessons and 1h 36 min. total duration.  See course details\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-13T22:53:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/02\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"952\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups\",\"name\":\"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg\",\"datePublished\":\"2024-02-13T22:53:11+00:00\",\"dateModified\":\"2024-02-13T22:53:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg\",\"width\":952,\"height\":675,\"caption\":\"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-mastering-transformer-vector-groups#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections - EEP Academy Courses","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups","og_locale":"en_US","og_type":"article","og_title":"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections - EEP Academy Courses","og_description":"This masterclass course provides a deep knowledge, understanding and analysis of transformer vector group connections and phasors. You will learn to analyze and draw connections of transformer windings. The course consists of 15 lessons and 1h 36 min. total duration.  See course details","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2024-02-13T22:53:38+00:00","og_image":[{"width":952,"height":675,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/02\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups","name":"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/02\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg","datePublished":"2024-02-13T22:53:11+00:00","dateModified":"2024-02-13T22:53:38+00:00","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/02\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/02\/course-mastering-transformer-vector-groups-analyze-draw-winding-connections-woo.jpg","width":952,"height":675,"caption":"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-mastering-transformer-vector-groups#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Mastering Transformer Vector Groups: Learn How To Analyze and Draw Windings Connections"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/20990","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=20990"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/20995"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=20990"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=20990"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=20990"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=20990"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}