{"id":22737,"date":"2024-09-27T13:34:41","date_gmt":"2024-09-27T11:34:41","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=22737"},"modified":"2024-09-27T13:34:41","modified_gmt":"2024-09-27T11:34:41","slug":"course-comprehensive-automatic-control-electrical-engineering","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering\/","title":{"rendered":"Comprehensive Automatic Control Theory in Electrical Engineering"},"content":{"rendered":"<p>Welcome to our course, \u201cComprehensive Automatic Control Theory in Electrical Engineering,\u201d designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.<\/p>\n<p>The course contains <strong>139 topics in 24h 35m total length<\/strong>.<\/p>\n<div class=\"info_box\">This course offers an <strong>extensive comprehension of control systems<\/strong>, encompassing fundamental principles to advanced methodologies, equipping students to effectively implement these skills in practical situations.<\/div>\n<p>The course begins with the <strong>fundamentals of control systems<\/strong>, encompassing the essential principles of automatic control. Students will acquire knowledge regarding the significance and applicability of control systems across different industries.<\/p>\n<p>Next, <strong>Mathematical Modelling<\/strong> is addressed. We will formulate mathematical models for electrical and mechanical systems. Students will acquire expertise in Fourier Series, Fourier Transform, Laplace Transform, and Linear Time-Invariant (LTI) systems.<\/p>\n<p>The third chapter is devoted to <strong>Block Diagram and Signal Flow Graph Techniques<\/strong>. Students will acquire proficiency in block diagrams and their reduction procedures, as well as the conversion of block diagrams into Signal Flow Graphs (SFG) and the application of Mason\u2019s Formula.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1012686737?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p><strong>Time Response Analysis<\/strong> is critically significant in Automation and Control systems and is addressed in the following chapter. We shall examine the time response of first and second-order systems. This chapter explains essential criteria such as rise time, peak time, and settling time.<\/p>\n<p>The fifth chapter pertains to <strong>Stability Analysis<\/strong>. We will assess system stability via the Routh-Hurwitz criterion and compute steady-state errors for various inputs and systems.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1012687129?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p>The next section provides a comprehensive explanation of <strong>Root-Locus and Frequency Response Methods<\/strong>. Students will acquire the skills to construct root-locus plots and evaluate their impact on system dynamics.<\/p>\n<p>We will conduct frequency response analysis utilizing polar plots, Nyquist criteria, and Bode plots.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1012690333?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p>The seventh chapter addresses critical issues, specifically <strong>Compensators and PID Controllers<\/strong>. Students will acquire the skills to develop and implement various compensators in control systems, along with a comprehensive understanding and tuning of PID controllers utilizing techniques such as Ziegler-Nichols and Particle Swarm Optimization.<\/p>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Course Summary<\/h2>\n<ol class=\"wp-block-list\">\n<li>Mathematical Modelling of Systems<\/li>\n<li>Block Diagram Reduction<\/li>\n<li>Signal Flow Graph<\/li>\n<li>Time Response Analysis<\/li>\n<li>Control System Stability<\/li>\n<li>Root-Locus Method<\/li>\n<li>Compensators in Control Systems<\/li>\n<li>PID Controllers<\/li>\n<li>Polar Plot<\/li>\n<li>Nyquist Criterion<\/li>\n<li>Bode Plot<\/li>\n<li>Design of Compensators Using Bode Plot<\/li>\n<\/ol>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For<\/h2>\n<ul class=\"wp-block-list\">\n<li>Undergraduate and graduate students in electrical, mechanical, and control engineering.<\/li>\n<li>Engineers and professionals looking to deepen their understanding of control systems and enhance their practical skills.<\/li>\n<li>Researchers focusing on control techniques and their applications.<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">Requirements<\/h2>\n<ul class=\"wp-block-list\">\n<li>Basic mathematics.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Welcome to our course, &#8220;Comprehensive Automatic Control Theory in Electrical Engineering,&#8221; designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers. The course consists in 139 topics in 24h 35m total length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/comprehensive-automatic-control-theory-electrical-engineering\">See course details<\/a><\/div>\n","protected":false},"author":9,"featured_media":22740,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[1977,38],"product_tag":[1961,1962,1973,1963,1964,1965,1970,1966,1972,1976,1974,1971,1969,1967,1968,1975],"class_list":["post-22737","product","type-product","status-publish","has-post-thumbnail","product_cat-automation-and-control","product_cat-uncategorized","product_tag-automatic-control","product_tag-automatic-control-theory","product_tag-bode-plots","product_tag-control-systems","product_tag-fourier-series","product_tag-fourier-transform","product_tag-frequency-response-methods","product_tag-laplace-transform","product_tag-nyquist-criteria","product_tag-particle-swarm-optimization","product_tag-pid-controllers","product_tag-polar-plots","product_tag-root-locus","product_tag-signal-flow-graph-techniques","product_tag-time-response-analysis","product_tag-ziegler-nichols","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Comprehensive Automatic Control Theory in Electrical Engineering - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Course designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Comprehensive Automatic Control Theory in Electrical Engineering - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Course designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/09\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"677\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering\",\"name\":\"Comprehensive Automatic Control Theory in Electrical Engineering - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg\",\"datePublished\":\"2024-09-27T11:34:41+00:00\",\"description\":\"Course designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg\",\"width\":1000,\"height\":677,\"caption\":\"Comprehensive Automatic Control Theory in Electrical Engineering\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-comprehensive-automatic-control-electrical-engineering#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Comprehensive Automatic Control Theory in Electrical Engineering\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Comprehensive Automatic Control Theory in Electrical Engineering - EEP Academy Courses","description":"Course designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering","og_locale":"en_US","og_type":"article","og_title":"Comprehensive Automatic Control Theory in Electrical Engineering - EEP Academy Courses","og_description":"Course designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","og_image":[{"width":1000,"height":677,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/09\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering","name":"Comprehensive Automatic Control Theory in Electrical Engineering - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/09\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg","datePublished":"2024-09-27T11:34:41+00:00","description":"Course designed to provide in-depth knowledge of automated control theory from the foundational level, specifically for electrical engineers.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/09\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2024\/09\/comprehensive-automatic-control-theory-electrical-engineering-woo.jpg","width":1000,"height":677,"caption":"Comprehensive Automatic Control Theory in Electrical Engineering"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-comprehensive-automatic-control-electrical-engineering#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Comprehensive Automatic Control Theory in Electrical Engineering"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/22737","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=22737"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/22740"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=22737"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=22737"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=22737"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=22737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}