{"id":23631,"date":"2025-01-09T23:36:32","date_gmt":"2025-01-09T22:36:32","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=23631"},"modified":"2025-01-09T23:36:32","modified_gmt":"2025-01-09T22:36:32","slug":"course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\/","title":{"rendered":"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting"},"content":{"rendered":"<p>In this all-encompassing 50-hour course, students will learn the ins and outs of three basic electrical machine types: DC machines, synchronous machines, and induction machines.<\/p>\n<p>This course will provide you with both theoretical foundations and practical applications that are essential for mastering electrical machines. Whether you are a student of electrical engineering, a professional working in the area, or someone who is looking to increase your competence in electrical machines, this course will equip you with that knowledge.<\/p>\n<p>The course consists in <strong>33 lessons and 298 topics<\/strong> in duration of <strong>50+ hours<\/strong>.<\/p>\n<div class=\"info_box\">By the end of this course, you will be able to cover all the principles of <strong>operation, design, and performance analysis of DC, Synchronous and Induction Machines<\/strong> through realizing real-world examples, industrial applications, and troubleshooting techniques.<\/div>\n<p>The course is structured in such a way that it is broken up into three major courses, each of which focuses on a different kind of machine:<\/p>\n<h2 class=\"wp-block-heading\"><strong>Part # 1:\u00a0DC Machines<\/strong><\/h2>\n<ul class=\"wp-block-list\">\n<li>The following topics are discussed in details:<\/li>\n<li>Introduction to DC machine principles<\/li>\n<li>Construction and operating principles.<\/li>\n<li>Armature reaction, commutation, and armature windings.<\/li>\n<li>DC generators types, features, and applications<\/li>\n<li>Performance characteristics and efficiency analysis of DC generators<\/li>\n<li>DC motors types, features, and applications<\/li>\n<li>Starting methods of DC motors<\/li>\n<li>Control methods, including speed control and torque regulation in DC motors<\/li>\n<li>DC machine testing<\/li>\n<li>Practical projects and applications on DC machine in MATLAB.<\/li>\n<\/ul>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1043798763?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media\"><\/iframe><\/p>\n<h2 class=\"wp-block-heading\"><strong>Part # 2:\u00a0Synchronous Machines<\/strong><\/h2>\n<ul class=\"wp-block-list\">\n<li>The following topics are discussed in details:<\/li>\n<li>Principles of synchronous machines<\/li>\n<li>Synchronous generator types, models, and characteristics<\/li>\n<li>Manufacturing of alternator windings<\/li>\n<li>Factors affecting the alternator voltage<\/li>\n<li>Role of governor control (ALFC) in alternators<\/li>\n<li>Role of excitation control (AVR) in alternators<\/li>\n<li>Types of exciters used in alternators<\/li>\n<li>Synchronous generator testing<\/li>\n<li>Performance and characteristics of stand alone generator<\/li>\n<li>Behavior of alternator operating with large power system<\/li>\n<li>Synchronization process of alternators with grid<\/li>\n<li>Parallel operation of alternators<\/li>\n<li>House diagram of alternators<\/li>\n<li>Synchronous generator ratings<\/li>\n<li>Learn how to read the nameplate of alternator<\/li>\n<li>Capability diagram and P-Q chart of alternators<\/li>\n<li>Complete analysis of salient pole alternators<\/li>\n<li>Reluctance motors<\/li>\n<li>Synchronous motors principles, working, model, and analysis<\/li>\n<li>Synchronous condenser<\/li>\n<li>Starting of synchronous motors<\/li>\n<li>Complete design of synchronous machines<\/li>\n<li>Stator and rotor design with several design problems<\/li>\n<li>Practical projects on synchronous machines in MATLAB.<\/li>\n<\/ul>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1043803529?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media\"><\/iframe><\/p>\n<h2 class=\"wp-block-heading\"><strong>Part # 3:\u00a0Induction Machines<\/strong><\/h2>\n<ul class=\"wp-block-list\">\n<li>Three phase induction motors overview<\/li>\n<li>Induction motors construction, types, model, and characteristics.<\/li>\n<li>Starting methods of induction motors<\/li>\n<li>Direct online, Start-delta starter, auto-transformer starter, soft starter, Rotor resistance starter<\/li>\n<li>Speed control of induction motors (Speed drives)<\/li>\n<li>V- control,\u00a0 F- control ,\u00a0 V\/F control, rotor resistance control, slip energy recovery control<\/li>\n<li>Variable frequency drives (VFD)<\/li>\n<li>Complete study of single phase induction motors<\/li>\n<li>Realize different methods to start single phase induction motors<\/li>\n<li>Induction motors testing<\/li>\n<li>Induction generators (Types, applications, features)<\/li>\n<li>Practical projects on induction machines in MATLAB.<\/li>\n<\/ul>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1043882012?dnt=1&amp;app_id=122963\" width=\"640\" height=\"342\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media\"><\/iframe><\/p>\n<h2 class=\"wp-block-heading\"><strong>Course Materials and Resources<\/strong><\/h2>\n<ul class=\"wp-block-list\">\n<li>Detailed lecture notes and reference material .<\/li>\n<li>900 lecture slides provided for you.<\/li>\n<li>Interactive quizzes and assignments for each course to reinforce learning.<\/li>\n<li>High quality video tutorials and demonstrations for simple understanding.<\/li>\n<li>Practical projects on MATLAB to model machine performance in electric system<\/li>\n<li>MATLAB Simulink files related to electrical machines provided for you.<\/li>\n<\/ul>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Course Summary<\/h2>\n<ol class=\"wp-block-list\">\n<li>DC Machines<\/li>\n<li>Synchronous Machines<\/li>\n<li>Induction machines<\/li>\n<\/ol>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For<\/h2>\n<ul class=\"wp-block-list\">\n<li>Electrical Engineers,<\/li>\n<li>Technologists,<\/li>\n<li>Industrial Technicians,<\/li>\n<li>Electricians,<\/li>\n<li>Students.<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">Requirements<\/h2>\n<ul class=\"wp-block-list\">\n<li>The basics of electric circuits<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>In this all-encompassing 50-hour course, students will learn both theoretical foundations and practical applications, examples and troubleshooting of three basic electrical machine types: DC machines, synchronous machines, and induction machines. The course consists in 33 lessons and 298 topics in duration of 50+ hours.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\">See course details<\/a><\/div>\n","protected":false},"author":2426,"featured_media":23633,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[701,504,338],"product_tag":[2042,2041,2029,2032,2028,505,2037,2030,507,2035,190,706,2039,2040,2036,2033,1555,548,2034,2031,2038],"class_list":["post-23631","product","type-product","status-publish","has-post-thumbnail","product_cat-electric-motor","product_cat-electrical-machines","product_cat-matlab-simulink","product_tag-alternator","product_tag-armature-winding","product_tag-dc-generators","product_tag-dc-machines","product_tag-dc-motors","product_tag-electrical-machines","product_tag-excited-dc-generator","product_tag-excited-dc-motor","product_tag-generators","product_tag-load-test","product_tag-matlab","product_tag-motor-starter","product_tag-motor-torque-speed","product_tag-salient-pole-machines","product_tag-separately-excited-dc-motor","product_tag-single-phase-induction-motors","product_tag-speed-control","product_tag-synchronous-generator","product_tag-synchronous-generator-simulation","product_tag-synchronous-machines","product_tag-synchronous-motors","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"In this all-encompassing 50-hour course, students will learn theoretical foundations and practical applications of electrical machines.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"In this all-encompassing 50-hour course, students will learn theoretical foundations and practical applications of electrical machines.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1131\" \/>\n\t<meta property=\"og:image:height\" content=\"855\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\",\"name\":\"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg\",\"datePublished\":\"2025-01-09T22:36:32+00:00\",\"description\":\"In this all-encompassing 50-hour course, students will learn theoretical foundations and practical applications of electrical machines.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg\",\"width\":1131,\"height\":855,\"caption\":\"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting - EEP Academy Courses","description":"In this all-encompassing 50-hour course, students will learn theoretical foundations and practical applications of electrical machines.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting","og_locale":"en_US","og_type":"article","og_title":"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting - EEP Academy Courses","og_description":"In this all-encompassing 50-hour course, students will learn theoretical foundations and practical applications of electrical machines.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","og_image":[{"width":1131,"height":855,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting","name":"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg","datePublished":"2025-01-09T22:36:32+00:00","description":"In this all-encompassing 50-hour course, students will learn theoretical foundations and practical applications of electrical machines.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting-woo.jpg","width":1131,"height":855,"caption":"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-advanced-electrical-machines-masterclass-examples-industrial-applications-troubleshooting#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Advanced Electrical Machines MasterClass: Examples, Industrial Applications and Troubleshooting"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/23631","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/2426"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=23631"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/23633"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=23631"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=23631"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=23631"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=23631"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}