{"id":23723,"date":"2025-01-25T00:04:51","date_gmt":"2025-01-24T23:04:51","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=23723"},"modified":"2025-01-25T00:04:51","modified_gmt":"2025-01-24T23:04:51","slug":"course-current-transformers-specifications-testing-examples-protection-measuring-applications","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications\/","title":{"rendered":"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications"},"content":{"rendered":"<p>This course is dedicated to Current Transformers (CTs), which are highly relevant to electrical protection and measuring systems. It covers the most significant aspect of <strong>how measurement and protective devices function<\/strong> in the electrical power system, and it includes testing procedures and real-world examples of the correct CT selection. The course is straightforward. It begins with an introduction to current transformers and the reasons for considering their construction and ends with training on how to select current transformers that fit measurement and protection devices using realistic calculations.<\/p>\n<p>Testing procedures of current transformers are discussed in depth by covering the most important ones, such as winding resistance test, insulation test, polarity and turn ratio tests, saturation test, etc.<\/p>\n<p>The course consists in 5 sections and 23 lectures in <strong>2h 14m total length<\/strong>. English subtitles are included.<\/p>\n<div class=\"info_box\">This course was developed utilizing the greatest engineering programs to connect the academic, theoretical element with practical reality through <strong>hands-on experience in electrical power substations<\/strong> with high and extra-high voltages.<\/div>\n<p>Practical expertise with distribution networks at medium and low voltages is inlcuded as well.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1049204908?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media\"><\/iframe><\/p>\n<p>This one-of-a-kind method of explanation and course preparation was designed to accommodate students from engineering universities and various technical institutes, as well as specialized engineers with extensive experience in the fields of electrical power systems and electrical substations, particularly in the areas of protection engineering and measuring applications.<\/p>\n<p>Instructor Ahmed Hassanin holds a master\u2019s degree in engineering sciences, specializing in electrical power and machine engineering, and possesses 19 years of practical expertise in electrical power substations.<\/p>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Course Summary:<\/h2>\n<ol class=\"wp-block-list\">\n<li>Introduction and Download Materials<\/li>\n<li>Practical explanation of Current Transformers (CT)<\/li>\n<li>Tests of Current Transformers (CT)<\/li>\n<li>Practical Example of Selecting CTs for Protective and Measuring Application<\/li>\n<li>Protective and measuring devices (connected to the electrical equipment)<\/li>\n<\/ol>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For:<\/h2>\n<ul class=\"wp-block-list\">\n<li>Substation engineers<\/li>\n<li>Practicing power system engineers<\/li>\n<li>Maintenance staff<\/li>\n<li>Electrical engineering students planning on pursuing a career in power engineering<\/li>\n<li>Power system protection engineers<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">Requirements:<\/h2>\n<ul class=\"wp-block-list\">\n<li>The basics of power systems<\/li>\n<li>Knowledge of basic substation terms<\/li>\n<li>Understanding the basic relay protection terminology and principles<\/li>\n<li>Passion and patience for learning.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This course is dedicated to Current Transformers (CTs), which are extremely important for electrical protection and measuring systems. It includes practical theory, testing procedures and real-world examples of the correct CT selection. 23 lessons in 2h 14m total length. English subtitles included.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring\">See course details<\/a><\/div>\n","protected":false},"author":5226,"featured_media":23728,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[160,145,332,1434],"product_tag":[1039,963,2062,2059,2063,2056,2058,2065,2066,2060,2067,2057,2064,2061],"class_list":["post-23723","product","type-product","status-publish","has-post-thumbnail","product_cat-power-substation","product_cat-power-system","product_cat-protection","product_cat-testing","product_tag-cts","product_tag-current-transformers","product_tag-insulation-test","product_tag-measuring-devices","product_tag-polarity-test","product_tag-protective-and-measuring-devices","product_tag-protective-devices","product_tag-saturation-test","product_tag-secondary-current","product_tag-secondary-winding-circuit","product_tag-suitable-ct","product_tag-testing-procedures","product_tag-turns-ratio-test","product_tag-winding-resistance-test","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"This course is dedicated to Current Transformers (CTs) and it includes practical theory, testing procedures and correct CT selection examples\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"This course is dedicated to Current Transformers (CTs) and it includes practical theory, testing procedures and correct CT selection examples\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"989\" \/>\n\t<meta property=\"og:image:height\" content=\"770\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications\",\"name\":\"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg\",\"datePublished\":\"2025-01-24T23:04:51+00:00\",\"description\":\"This course is dedicated to Current Transformers (CTs) and it includes practical theory, testing procedures and correct CT selection examples\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg\",\"width\":989,\"height\":770,\"caption\":\"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications - EEP Academy Courses","description":"This course is dedicated to Current Transformers (CTs) and it includes practical theory, testing procedures and correct CT selection examples","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications","og_locale":"en_US","og_type":"article","og_title":"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications - EEP Academy Courses","og_description":"This course is dedicated to Current Transformers (CTs) and it includes practical theory, testing procedures and correct CT selection examples","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","og_image":[{"width":989,"height":770,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications","name":"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg","datePublished":"2025-01-24T23:04:51+00:00","description":"This course is dedicated to Current Transformers (CTs) and it includes practical theory, testing procedures and correct CT selection examples","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/01\/practical-course-current-transformers-cts-specifications-testing-examples-protection-measuring-wc.jpg","width":989,"height":770,"caption":"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-current-transformers-specifications-testing-examples-protection-measuring-applications#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Practical Course to Current Transformers (CTs): Specifications, Testing and Examples in Protection and Measuring Applications"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/23723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/5226"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=23723"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/23728"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=23723"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=23723"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=23723"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=23723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}