{"id":25104,"date":"2025-09-17T17:34:06","date_gmt":"2025-09-17T15:34:06","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=25104"},"modified":"2025-09-17T17:34:06","modified_gmt":"2025-09-17T15:34:06","slug":"course-proper-grounding-and-fault-mitigation","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation\/","title":{"rendered":"Advanced Course in Proper Grounding and Fault Mitigation"},"content":{"rendered":"<p>This course provides an advanced knowledge in grounding and fault mitigation in power systems. It covers the basic grounding and protection concepts, short-circuit in isolated networks, phenomena associated with ground faults, grounding of low-voltage and medium-voltage systems, grounding system circuits, and finally specifications and ratings of grounding devices.<\/p>\n<p>The course consists of a total of <strong>52 lessons<\/strong> and has a duration of <strong>3 hours and 5 minutes<\/strong>.<\/p>\n<p>The course is intended for both lower- and upper-level undergraduate students studying power system, design, and measurement of grounding system, as well as a reference for power system engineers.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1117719161?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p>This course is organized into seven chapters. <strong>Chapter 1<\/strong> \u201cBasic Concepts\u201d deals with the course preview, and the preview of short-circuit current calculations. Short-circuit in isolated networks are discussed in <strong>Chapter 2<\/strong>.<\/p>\n<p><strong>Chapter 3<\/strong> covers Phenomena associated with ground faults (such as transient overvoltages, arcing ground, false motor starting, etc.).<\/p>\n<p><strong>Chapter 4<\/strong> includes the grounding of low voltage systems. In this chapter, we\u2019ll discuss experience-based guidelines for grounding \u2013 Industrial systems and transmission lines, natural capacitances, grounding transformers, methods of grounding, etc.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1117720490?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p><strong>Chapter 5<\/strong> presents facts on grounding of medium voltage systems by diving into residual relaying scheme, ground sensor scheme, neutral ground scheme, and other important topics.<\/p>\n<p><strong>Chapter 6<\/strong> describes different grounding system circuits and guidelines. Grounding of systems in hazardous areas and ferroresonance phenomenon are also covered in this Chapter. Specifications and ratings of grounding devices in <strong>Chapter 7<\/strong>.<\/p>\n<p>This course will offer both students and practice engineers the fundamental concepts in grounding and fault mitigation in power systems.<\/p>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1117722918?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p><strong>This course will teach you the following:<\/strong><\/p>\n<ul class=\"wp-block-list\">\n<li>A quick overview of the fundamentals of short-circuit current calculations.<\/li>\n<li>Short-circuit currents in isolated networks.<\/li>\n<li>Earthing or grounding impedance.<\/li>\n<li>How fault currents can be controlled by adjusting the neutral grounding method.<\/li>\n<li>Ground fault in isolated, unearthed, systems.<\/li>\n<li>Transient overvoltages and how they occur in ungrounded systems.<\/li>\n<li>Important effects that can occur when a ground fault happens.<\/li>\n<li>An important phenomenon known as the Second Short Circuit<\/li>\n<li>The phenomenon of arcing ground\u2014what it is, how it happens, and why it can be dangerous.<\/li>\n<li>The phenomenon of false starting in motors.<\/li>\n<li>Grounding in low-voltage systems.<\/li>\n<li>Primary objectives of system grounding.<\/li>\n<li>Experience-based guidelines for grounding.<\/li>\n<li>Natural capacitances in electrical networks.<\/li>\n<li>Grounding transformers and their roles in electrical systems.<\/li>\n<li>How grounding transformers can be used to limit fault current.<\/li>\n<li>The Zigzag Grounding Transformer and its key considerations.<\/li>\n<li>Grounding Methods.<\/li>\n<li>Ungrounded Networks.<\/li>\n<li>Direct and Effective Grounding.<\/li>\n<li>High Resistance Grounding.<\/li>\n<li>Final recommendation for the types of grounding used in low-voltage networks.<\/li>\n<li>Grounding methods used in medium-voltage systems.<\/li>\n<li>Ungrounded Systems.<\/li>\n<li>Solid Grounding.<\/li>\n<li>Low-Resistance Grounding.<\/li>\n<li>High Resistance Grounding.<\/li>\n<li>Reactance Grounding.<\/li>\n<li>Ground Fault Neutralizer Grounding.<\/li>\n<li>Protection Schemes used in medium-voltage systems.<\/li>\n<li>Residual Relaying Scheme.<\/li>\n<li>Ground Sensor Scheme.<\/li>\n<li>Neutral Ground Scheme.<\/li>\n<li>Grounding systems in hazardous areas.<\/li>\n<li>Grounding and the ferroresonance phenomenon.<\/li>\n<li>Ratings and specifications of grounding devices.<\/li>\n<li>The steps for selecting and determining ratings for the grounding by reactance and grounding with a Zigzag transformer.<\/li>\n<\/ul>\n<p><\/p>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Course Overview<\/h2>\n<ol class=\"wp-block-list\">\n<li>Basic Grounding and Protection Concepts<\/li>\n<li>Short-Circuit in Isolated Networks<\/li>\n<li>Phenomena Associated with Ground Faults<\/li>\n<li>Grounding of Low-voltage Systems<\/li>\n<li>Grounding of Medium-voltage Systems<\/li>\n<li>Grounding System Circuits<\/li>\n<li>Specifications and Ratings of Grounding Devices<\/li>\n<\/ol>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For<\/h2>\n<ul class=\"wp-block-list\">\n<li>Engineering college students and students of technical institutes<\/li>\n<li>Engineers and technicians working in power stations and distribution networks<\/li>\n<li>Specialists involved in the study and mitigation of short-circuit currents in electrical power networks<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">Requirements<\/h2>\n<ul class=\"wp-block-list\">\n<li>Basic knowledge of AC circuits<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding &amp; protection concepts, short-circuit in isolated networks, phenomena associated with ground faults, grounding of LV\/MV systems, grounding system circuits, and finally specifications and ratings of grounding devices. 52 lessons in 3 hours and 5 minutes.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/advanced-course-proper-grounding-fault-mitigation\">See course details<\/a><\/div>\n","protected":false},"author":5226,"featured_media":25107,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[2229,332,117],"product_tag":[1002,2232,2238,995,2230,2242,766,2235,2241,2233,2234,2244,2231,2236,2243,477,1080,2237,2239,2240],"class_list":["post-25104","product","type-product","status-publish","has-post-thumbnail","product_cat-grounding","product_cat-protection","product_cat-relay-protection","product_tag-fault-current","product_tag-fault-mitigation","product_tag-ferroresonance","product_tag-ground-fault","product_tag-ground-faults","product_tag-ground-sensor","product_tag-grounding","product_tag-grounding-devices","product_tag-grounding-methods","product_tag-grounding-system","product_tag-grounding-transformers","product_tag-industrial-systems","product_tag-isolated-networks","product_tag-medium-voltage-systems","product_tag-relaying-scheme","product_tag-short-circuit","product_tag-short-circuit-current","product_tag-transient-overvoltages","product_tag-ungrounded-systems","product_tag-zigzag-grounding","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Advanced Course in Proper Grounding and Fault Mitigation - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding and protection concepts.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Advanced Course in Proper Grounding and Fault Mitigation - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding and protection concepts.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/09\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"824\" \/>\n\t<meta property=\"og:image:height\" content=\"573\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation\",\"name\":\"Advanced Course in Proper Grounding and Fault Mitigation - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg\",\"datePublished\":\"2025-09-17T15:34:06+00:00\",\"description\":\"This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding and protection concepts.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg\",\"width\":824,\"height\":573,\"caption\":\"Advanced Course in Proper Grounding and Fault Mitigation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-proper-grounding-and-fault-mitigation#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Advanced Course in Proper Grounding and Fault Mitigation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Advanced Course in Proper Grounding and Fault Mitigation - EEP Academy Courses","description":"This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding and protection concepts.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation","og_locale":"en_US","og_type":"article","og_title":"Advanced Course in Proper Grounding and Fault Mitigation - EEP Academy Courses","og_description":"This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding and protection concepts.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","og_image":[{"width":824,"height":573,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/09\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation","name":"Advanced Course in Proper Grounding and Fault Mitigation - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/09\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg","datePublished":"2025-09-17T15:34:06+00:00","description":"This course provides an advanced knowledge in grounding and fault mitigation in power systems. Learn grounding and protection concepts.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/09\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/09\/advanced-course-proper-grounding-fault-mitigation-woo2.jpg","width":824,"height":573,"caption":"Advanced Course in Proper Grounding and Fault Mitigation"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-proper-grounding-and-fault-mitigation#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Advanced Course in Proper Grounding and Fault Mitigation"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/25104","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/5226"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=25104"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/25107"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=25104"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=25104"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=25104"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=25104"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}