{"id":25439,"date":"2025-11-06T21:14:53","date_gmt":"2025-11-06T20:14:53","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=25439"},"modified":"2025-11-14T14:46:59","modified_gmt":"2025-11-14T13:46:59","slug":"practical-course-power-system-operation-control-stability-optimization","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/","title":{"rendered":"Practical Course to Power System Operation, Control, Stability, and Optimization"},"content":{"rendered":"<p>This course covers all aspects of power system operation and control, beginning with the analysis of power system stability, progressing to voltage and frequency regulation, and concluding with the development of an optimal economic power network.<\/p>\n<p>The course consists of <strong>15 chapters and 130 lectures<\/strong> with a duration of <strong>16 hours<\/strong>.<\/p>\n<p>The course is structured as follows:<\/p>\n<p><strong>Initially, an overview of power system stability is presented through the following topics:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>What is power system stability?<\/li>\n<li>Types of disturbances affecting the power system<\/li>\n<li>Power system stability classification<\/li>\n<li>Rotor angle stability<\/li>\n<li>Frequency stability<\/li>\n<li>Voltage stability<\/li>\n<\/ol>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1122420628?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p><strong>The swing equation, the central equation for transients in power systems, will be covered in the following section. Here are the subjects that will be discussed:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>Synchronous machine modelling<\/li>\n<li>Types of synchronous machines<\/li>\n<li>Machine reactances during transients.<\/li>\n<li>What is rotor angle?<\/li>\n<li>Swing equation analysis<\/li>\n<li>Accelerating torque.<\/li>\n<\/ol>\n<p><strong>Further on, we\u2019ll go over the Single Machine Infinite Bus System (SMIB), a crucial component of power system research. Here are the subjects that will be discussed:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>Classical model for stability studies<\/li>\n<li>Power angle curve<\/li>\n<li>SMIB before faults<\/li>\n<li>SMIB during faults<\/li>\n<li>SMIB after faults<\/li>\n<\/ol>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1122421489?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p><strong>After that, you will have a thorough understanding of SSSA, or Small Signal Stability Analysis. Here are the subjects that will be discussed:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>Damping power<\/li>\n<li>Linearization of swing equation<\/li>\n<li>Small signal model<\/li>\n<li>Checking system stability<\/li>\n<li>The system time domain response<\/li>\n<li>Forced and free disturbances<\/li>\n<li>Applications on MATLAB\/Simulink<\/li>\n<\/ol>\n<p><strong>Studies of transient stability will be covered next. The following are some general guidelines for determining how to evaluate a system\u2019s stability\u00a0to disturbances:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>What is transient stability?<\/li>\n<li>Sudden increase in mechanical power<\/li>\n<li>Equal Area Criterion (EAC)<\/li>\n<li>Accelerating &amp; Decelerating areas<\/li>\n<li>Transient stability margin<\/li>\n<li>Applications \u2013 3-phase faults on Transients Stability<\/li>\n<li>Critical clearing angle &amp; time<\/li>\n<\/ol>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1122423973?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p><strong>Coming up after that, we\u2019ll go over power system control, where you\u2019ll learn all about controlling voltage and frequency in power networks. First, the following subjects cover the automated voltage regulator (AVR) in detail:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>Excitation systems<\/li>\n<li>AVR modelling<\/li>\n<li>AVR closed loop transfer function<\/li>\n<li>Static accuracy limit<\/li>\n<li>AVR dynamic response<\/li>\n<li>AVR root locus<\/li>\n<li>Applications on MATLAB\/Simulink<\/li>\n<\/ol>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/1122426277?dnt=1&amp;app_id=122963\" width=\"640\" height=\"360\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write; encrypted-media; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\"><\/iframe><\/p>\n<p><strong>The following are some detailed explanations of load frequency control (LFC) that will help you understand how to keep the frequency steady:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>Speed changer, speed sensor, hydraulic amplifier<\/li>\n<li>Governor, generator, turbine , load modelling<\/li>\n<li>Static performance of speed governor<\/li>\n<li>LFC steady state analysis<\/li>\n<li>Secondary LFC loop<\/li>\n<li>LFC in Multi Control Area Systems \u2013 Pool Operation<\/li>\n<li>Tie line modelling<\/li>\n<li>Block diagram representation of two area system<\/li>\n<li>Applications on MATLAB\/Simulink<\/li>\n<\/ol>\n<p><strong>Optimal economic dispatch (OED) is the course\u00a0last lesson, and it teaches you how to minimize generation costs while still meeting load demand. Here are the main points:<\/strong><\/p>\n<ol class=\"wp-block-list\">\n<li>Factors affecting ED problem<\/li>\n<li>Cost function &amp; incremental cost<\/li>\n<li>Static performance of speed governor<\/li>\n<li>Lagrangian multiplier method<\/li>\n<li>ED Problem Neglecting Transmission Losses<\/li>\n<li>ED problem considering transmission losses<\/li>\n<li>Kron\u2019s formula (Loss formula)<\/li>\n<li>Steps of solution using successive algorithm<\/li>\n<\/ol>\n<hr \/>\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Course Summary<\/h2>\n<ol class=\"wp-block-list\">\n<li>Power system stability<\/li>\n<li>The swing equation in power systems<\/li>\n<li>Single machine infinite bus<\/li>\n<li>Small signal stability<\/li>\n<li>System time domain response<\/li>\n<li>Applications on MATLAB Simulink \u2013 Small Signal Stability<\/li>\n<li>Transient stability<\/li>\n<li>Applications \u2013 Three Phase Faults on Transients Stability<\/li>\n<li>Power System Control<\/li>\n<li>AVR Control System<\/li>\n<li>Aplications on MATLAB Simulink \u2013 AVR Control<\/li>\n<li>LFC in single area system<\/li>\n<li>LFC in Multi Control Area Systems \u2013 Pool Operation<\/li>\n<li>Applications on MATLAB Simulink \u2013 LFC<\/li>\n<li>Economic Dispatch<\/li>\n<\/ol>\n<\/div>\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Who Is This Course For<\/h2>\n<ul class=\"wp-block-list\">\n<li>Technicians and engineers that work in electrical power sectors like generation, distribution or transmission of electric and also industrial areas.<\/li>\n<li>Electrical engineering students.<\/li>\n<li>Anyone who wants to learn about electrical power engineering.<\/li>\n<\/ul>\n<h2 class=\"wp-block-heading\">Requirements<\/h2>\n<p>Having basic knowledge about power engineering<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>This masterclass covers power system operation and control starting from analyzing power system stability moving to system voltage and frequency control, ending with building an optimal economical power network. The course consists in 130 lectures in 16 hours.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\"><a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/power-system-operation-control-stability-optimization\/\">See course details<\/a><\/div>\n","protected":false},"author":2426,"featured_media":25443,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[145,116],"product_tag":[2303,2294,2299,2300,2291,2302,561,2301,2293,203,2296,2292,1383,2298,2304,1342,2305,2295,2297],"class_list":["post-25439","product","type-product","status-publish","has-post-thumbnail","product_cat-power-system","product_cat-transmission-and-distribution","product_tag-avr-control-system","product_tag-avr-root-locus","product_tag-load-frequency-control","product_tag-machine-infinite-bus","product_tag-matlab-simulink","product_tag-operation-control-stability","product_tag-power-system","product_tag-power-system-control","product_tag-power-system-operation","product_tag-power-system-stability","product_tag-rotor-angle-stability","product_tag-small-signal-stability","product_tag-swing-equation","product_tag-systems-pool-operation","product_tag-three-phase-faults","product_tag-transients","product_tag-transients-stability","product_tag-transmission-line","product_tag-transmission-losses","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Practical Course to Power System Operation, Control, Stability, and Optimization - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"This course covers power system operation and control, starting with analyzing power system stability, moving on to system voltage &amp; frequency\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Practical Course to Power System Operation, Control, Stability, and Optimization - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"This course covers power system operation and control, starting with analyzing power system stability, moving on to system voltage &amp; frequency\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-14T13:46:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/11\/course-power-system-operation-control-stability-optimization-woo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"970\" \/>\n\t<meta property=\"og:image:height\" content=\"687\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/\",\"name\":\"Practical Course to Power System Operation, Control, Stability, and Optimization - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/course-power-system-operation-control-stability-optimization-woo.jpg\",\"datePublished\":\"2025-11-06T20:14:53+00:00\",\"dateModified\":\"2025-11-14T13:46:59+00:00\",\"description\":\"This course covers power system operation and control, starting with analyzing power system stability, moving on to system voltage & frequency\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/course-power-system-operation-control-stability-optimization-woo.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/course-power-system-operation-control-stability-optimization-woo.jpg\",\"width\":970,\"height\":687,\"caption\":\"Practical Course to Power System Operation, Control, Stability, and Optimization\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/practical-course-power-system-operation-control-stability-optimization\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Practical Course to Power System Operation, Control, Stability, and Optimization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Practical Course to Power System Operation, Control, Stability, and Optimization - EEP Academy Courses","description":"This course covers power system operation and control, starting with analyzing power system stability, moving on to system voltage & frequency","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/","og_locale":"en_US","og_type":"article","og_title":"Practical Course to Power System Operation, Control, Stability, and Optimization - EEP Academy Courses","og_description":"This course covers power system operation and control, starting with analyzing power system stability, moving on to system voltage & frequency","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2025-11-14T13:46:59+00:00","og_image":[{"width":970,"height":687,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/11\/course-power-system-operation-control-stability-optimization-woo.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/","name":"Practical Course to Power System Operation, Control, Stability, and Optimization - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/11\/course-power-system-operation-control-stability-optimization-woo.jpg","datePublished":"2025-11-06T20:14:53+00:00","dateModified":"2025-11-14T13:46:59+00:00","description":"This course covers power system operation and control, starting with analyzing power system stability, moving on to system voltage & frequency","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/11\/course-power-system-operation-control-stability-optimization-woo.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2025\/11\/course-power-system-operation-control-stability-optimization-woo.jpg","width":970,"height":687,"caption":"Practical Course to Power System Operation, Control, Stability, and Optimization"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/practical-course-power-system-operation-control-stability-optimization\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Practical Course to Power System Operation, Control, Stability, and Optimization"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/25439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/2426"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=25439"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/25443"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=25439"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=25439"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=25439"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=25439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}