{"id":5074,"date":"2021-08-06T18:18:23","date_gmt":"2021-08-06T18:18:23","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=5074"},"modified":"2022-02-03T09:37:40","modified_gmt":"2022-02-03T08:37:40","slug":"course-dc-circuit-analysis-fundamentals","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals\/","title":{"rendered":"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included)"},"content":{"rendered":"<p>This course examines <strong>Ohm\u2019s Law, Series and Parallel Circuits<\/strong>, the first, and perhaps most important, the relationship between current, voltage, and impedance, Ohm\u2019s Law, and its relevance to Series and Parallel Circuits. Subsequently, this will lead to the development of Kirchhoff\u2019s Laws as they help to further analyze network analysis and metering circuits. The course includes the most common practice problems students face during solving the circuits.<\/p>\n<p>Conductors and Insulators are investigated along with their connected components, Capacitors, Inductors and how they are influenced by Electromagnetism.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Course Summary:<\/strong><\/span><\/p>\n<ol>\n<li>Intro basic electricity<\/li>\n<li>The Nature of electricity<\/li>\n<li>Conductors &amp; Insulators<\/li>\n<li>Current and Electric Circuits<\/li>\n<li>Ohm\u2019s Law<\/li>\n<li>Electric Power<\/li>\n<li>Series and Parallel Circuits<\/li>\n<li>Circuit Theorems<\/li>\n<li>Electric Fields and Capacitance<\/li>\n<li>Magnetism and Inductance<\/li>\n<li>Transient Response Capacitors and Inductors<\/li>\n<li>Practice Problems for DC Circuit Analysis<\/li>\n<li>The Final Exam With 25 Questions<\/li>\n<\/ol>\n<p>For more information visit the course page:<\/p>\n<blockquote class=\"wp-embedded-content\" data-secret=\"e8sCroK83I\"><p><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/dc-circuit-analysis-fundamentals\">The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included)<\/a><\/p><\/blockquote>\n<p><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; clip: rect(1px, 1px, 1px, 1px);\" title=\"&#8220;The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included)&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/dc-circuit-analysis-fundamentals\/embed#?secret=yo5w41vxyO#?secret=e8sCroK83I\" data-secret=\"e8sCroK83I\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This course introduces the fundamental concepts of electrical direct current (DC) circuits (Ohm\u2019s Law, Kirchhoff&#8217;s Laws, Series and Parallel Circuits, etc.) and the most common practice problems students face during studying. 12 sections in 4h 40min total course length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the course\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/dc-circuit-analysis-fundamentals\">See course details<\/a>\n<\/div>\n","protected":false},"author":15,"featured_media":4989,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[178],"product_tag":[368,370,182,369,183,181],"class_list":["post-5074","product","type-product","status-publish","has-post-thumbnail","product_cat-electric-circuits","product_tag-basic-electricity","product_tag-circuit-theorems","product_tag-current","product_tag-dc-circuits","product_tag-power","product_tag-voltage","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included) - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"This course examines Ohm\u2019s Law, Series and Parallel Circuits, the relationship between current, voltage, and impedance, Ohm\u2019s Law.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included) - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"This course examines Ohm\u2019s Law, Series and Parallel Circuits, the relationship between current, voltage, and impedance, Ohm\u2019s Law.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2022-02-03T08:37:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/dc-circuit-analysis-fundamentals-course-.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"372\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals\",\"name\":\"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included) - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/dc-circuit-analysis-fundamentals-course-.jpg\",\"datePublished\":\"2021-08-06T18:18:23+00:00\",\"dateModified\":\"2022-02-03T08:37:40+00:00\",\"description\":\"This course examines Ohm\u2019s Law, Series and Parallel Circuits, the relationship between current, voltage, and impedance, Ohm\u2019s Law.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/dc-circuit-analysis-fundamentals-course-.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/dc-circuit-analysis-fundamentals-course-.jpg\",\"width\":600,\"height\":372,\"caption\":\"DC Circuit Analysis: Fundamentals Course for Electrical Engineers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-dc-circuit-analysis-fundamentals#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included) - EEP Academy Courses","description":"This course examines Ohm\u2019s Law, Series and Parallel Circuits, the relationship between current, voltage, and impedance, Ohm\u2019s Law.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals","og_locale":"en_US","og_type":"article","og_title":"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included) - EEP Academy Courses","og_description":"This course examines Ohm\u2019s Law, Series and Parallel Circuits, the relationship between current, voltage, and impedance, Ohm\u2019s Law.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2022-02-03T08:37:40+00:00","og_image":[{"width":600,"height":372,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/dc-circuit-analysis-fundamentals-course-.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals","name":"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included) - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/dc-circuit-analysis-fundamentals-course-.jpg","datePublished":"2021-08-06T18:18:23+00:00","dateModified":"2022-02-03T08:37:40+00:00","description":"This course examines Ohm\u2019s Law, Series and Parallel Circuits, the relationship between current, voltage, and impedance, Ohm\u2019s Law.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/dc-circuit-analysis-fundamentals-course-.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/dc-circuit-analysis-fundamentals-course-.jpg","width":600,"height":372,"caption":"DC Circuit Analysis: Fundamentals Course for Electrical Engineers"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-dc-circuit-analysis-fundamentals#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"The Essentials of Electricity and DC Circuit Analysis (Practice Problems Included)"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/5074","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=5074"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/4989"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=5074"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=5074"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=5074"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=5074"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}