{"id":5376,"date":"2021-08-07T09:01:16","date_gmt":"2021-08-07T09:01:16","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=5376"},"modified":"2024-11-13T21:34:42","modified_gmt":"2024-11-13T20:34:42","slug":"course-instrument-electric-power-metering","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering\/","title":{"rendered":"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry"},"content":{"rendered":"<p>This course presents the fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital and analog wattmeters, Kwhr meters, polyphase connections.<\/p>\n<p><strong>Upon completion participants will be familiar with:<\/strong><\/p>\n<ul>\n<li>What is Electric Power<\/li>\n<li>AC &amp; DC Power<\/li>\n<li>Voltage, Current, &amp; Power Vectors (Phasors)<\/li>\n<li>Capacitive &amp; Inductive Loads<\/li>\n<li>Real, Reactive &amp; Apparent Power (Watts, Vars, VA)<\/li>\n<li>What is Electric Power<\/li>\n<li>The Dynamometer Wattmeter<\/li>\n<li>The Energy Meter<\/li>\n<li>Single-Phase Metering<\/li>\n<li>3-Wire, Single-Phase Metering<\/li>\n<li>Instrument Transformers (Current &amp; Voltage CTs &amp; PTs)<\/li>\n<li>Polyphase Energy Meters<\/li>\n<li>3-Wire, Single-Phase Metering with CTs\/PTs<\/li>\n<li>Metering a 3 Phase 4 Wire Load (\u201cY\u201d Connected)<\/li>\n<li>Metering a 3 Phase 3 Wire Load (Delta Connected)<\/li>\n<li>Measurement Canada Standards<\/li>\n<li>Blondel\u2019s Theorem<\/li>\n<li>Phase &amp; Line Relationship<\/li>\n<\/ul>\n<p>For more information visit the course page:<\/p>\n<blockquote class=\"wp-embedded-content\" data-secret=\"AzCddiBHgM\"><p><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/instrument-electric-power-metering-utilities-industry-fundamentals\">Fundamentals of Instrument and Electric Power Metering in Utilities and Industry<\/a><\/p><\/blockquote>\n<p><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; visibility: hidden;\" title=\"&#8220;Fundamentals of Instrument and Electric Power Metering in Utilities and Industry&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/instrument-electric-power-metering-utilities-industry-fundamentals\/embed#?secret=b0RPJhA9yX#?secret=AzCddiBHgM\" data-secret=\"AzCddiBHgM\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Learn fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital &amp; analog wattmeters, Kwhr meters. 8 lessons in 4h 7min total course length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the couse\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/instrument-electric-power-metering-utilities-industry-fundamentals\">See course details<\/a>\n<\/div>\n","protected":false},"author":15,"featured_media":5246,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[389,145],"product_tag":[182,391,183,390,181],"class_list":["post-5376","product","type-product","status-publish","has-post-thumbnail","product_cat-metering","product_cat-power-system","product_tag-current","product_tag-instrument-transformers","product_tag-power","product_tag-power-metering","product_tag-voltage","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fundamentals of Instrument and Electric Power Metering in Utilities and Industry - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Learn fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital &amp; analog wattmeters, Kwhr meters\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Learn fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital &amp; analog wattmeters, Kwhr meters\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-13T20:34:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"971\" \/>\n\t<meta property=\"og:image:height\" content=\"640\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering\",\"name\":\"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg\",\"datePublished\":\"2021-08-07T09:01:16+00:00\",\"dateModified\":\"2024-11-13T20:34:42+00:00\",\"description\":\"Learn fundamentals of instrument and single-phase\\\/three-phase metering in utilities and industry, digital & analog wattmeters, Kwhr meters\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg\",\"width\":971,\"height\":640,\"caption\":\"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-instrument-electric-power-metering#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry - EEP Academy Courses","description":"Learn fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital & analog wattmeters, Kwhr meters","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering","og_locale":"en_US","og_type":"article","og_title":"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry - EEP Academy Courses","og_description":"Learn fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital & analog wattmeters, Kwhr meters","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2024-11-13T20:34:42+00:00","og_image":[{"width":971,"height":640,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering","name":"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg","datePublished":"2021-08-07T09:01:16+00:00","dateModified":"2024-11-13T20:34:42+00:00","description":"Learn fundamentals of instrument and single-phase\/three-phase metering in utilities and industry, digital & analog wattmeters, Kwhr meters","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/fundamentals-instrument-electric-power-metering-utilities-industry.jpg","width":971,"height":640,"caption":"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-instrument-electric-power-metering#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Fundamentals of Instrument and Electric Power Metering in Utilities and Industry"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/5376","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=5376"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/5246"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=5376"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=5376"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=5376"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=5376"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}